Safety & Installation Instructions
These instructions are provided for your safety in order to prevent the risk of Fire, Electric shock or Injury. It is vitally
important that they are read in their entirety before installing your fitting. Please retain for future reference.
1. If you are in any doubt consult a qualified electrician as to the installation of the fitting. Install in accordance with current
IEE wiring regulations. It is recommended that this fitting is installed by a qualified electrician.
2. Ensure that the electrical supply is OFF. Disconnect the electrical supply at the fuse-board.
3. If removing an existing fitting first, note all wiring connections: record which of the house wires is connected to the live,
neutral and earth terminals.
4. Carefully identify where the supply cable is (and check there are no other cables in the area) to avoid damage to concealed
wiring during installation.
5. Position the light where desired ensuring that there is suitable support adjacent to where you will connect to the house
supply and mark position of fixing holes, before creating an appropriate recess for the fitting. The light will require a recess
of 65mm x 65mm x125mm.
6. Support the fitting so that no strain is applied to the wiring when making the electrical connections. If necessary get a
colleague to help.
7. Electrical connection: this light fitting must be earthed. Make connections following the diagram below. A small flat-head
screwdriver is required.
KEY
BROWN
L =
Live
Fitting
GRN/YEL
N =
Neutral
=
Earth
N
BLUE
8. Double check all the connections are secure and that no loose strands of wire are left out of the connector, Use a good
quality electrical insulation tape to cover the connector blocks and at least 25mm of the cables going in to either end of the
connectors.
9.
Check that no wires are trapped behind or within the fitting and complete the installation, referring to the Installation
diagram inside.
10. Fit the correct type and wattage of lamp (or less).
11. Switch on at the fuse-board. Your light fitting is now ready for use.
Other Important Information
Switch off at mains before changing lamp(s). Never fit a lamp of greater wattage than recommended. Ensure children do not
play with the light fitting. Dispose of old lamps carefully. Never leave a fitting without a lamp in position (or someone can
accidentally touch the contacts). Adjust fitting only when power to the fitting is off and has been left to cool. If the electrical
flex or electrical components become damaged at any point, power to the fitting should be disconnected immediately and not
operated until the damaged parts are fixed/replaced.
Cleaning and Maintenance
Metal finishes should only be cleaned with a soft, dry cloth. Do not use polishes or abrasives. Glass can be cleaned by hand,
using a soft damp cloth with a diluted mild detergent (nonabrasive) or suitable glass cleaner if necessary. Switch off power to
the fitting before cleaning. Spare parts are available for this product, please contact us on the details below.
Established in 1990, Original BTC manufactures relaxed, familiar lighting for traditional and contemporary homes.
All products are hand-assembled in Oxford from high quality components, produced in the UK.
ORIGINALBTC.COM
+44 (0)1993 882 251
UNIT 21 / 22 AVENUE ONE, STATION LANE, WITNEY, OX28 4XZ, ENGLAND
*After 2004, wiring installation colours changed:
L
BROWN
*Mains
LIVE
Brown replaces Red
GRN/YEL
Supply
EARTH
Green/Yellow sleeving
BLUE
NEUTRAL Blue replaces Black
Low Voltage Recessed Step Light
v1.2-06.20
With Back Box
Instruction Manual
MADE IN BRITAIN
7601

Advertisement

loading

Summary of Contents for Davey Lighting Original BTC 7601

  • Page 1 Low Voltage Recessed Step Light Safety & Installation Instructions v1.2-06.20 With Back Box These instructions are provided for your safety in order to prevent the risk of Fire, Electric shock or Injury. It is vitally 7601 important that they are read in their entirety before installing your fitting. Please retain for future reference. 1.
  • Page 2 Low Voltage Recessed Step Light With Back Box 7601 Installation and Assembly Instructions 230V ac 50Hz IP54 Refer to diagrams below. LAMP GUIDANCE - Using appropriate tools, make a cut out in the wall where the light is to be installed. BASE SHAPE TYPE*...