BROSA 0210 Operating Manual

Shear force transducer

Advertisement

Quick Links

Operating Manual
BROSA Type 0210 Shear Force Transducer
Version: 05/2020
................................................................................................................................................................
BROSA AG
Dr. Klein Straße 1
D-88069 Tettnang
Phone: +49(0)7542 93 35 0
Fax:
+49(0)7542 93 35 35
info@brosa.net
www.brosa.net
BROSA Pte Ltd
BROSA B.V.
25 Lorong Kilat #02-01
Galliershof 38
Singapore 598126
NL - 5349 BV Oss, Netherlands
Phone: +65 6795 2324
Phone: +31 412 6146 02
Fax:
+65 6795 2428
Fax:
info.sg@brosa.net
info@brosa.nl
BROSA (Nanjing) Co., Ltd.
Jinma Lu 3, Maqun Scientific Park, Qixia District
210049 Nanjing
Phone: +86 (25)8222 4639
+31 412 6146 86
Fax:
info.cn@brosa.net
© 2018 BROSA AG, Tettnang, Germany
+86 (25)8222 4639

Advertisement

Table of Contents
loading

Summary of Contents for BROSA 0210

  • Page 1 Operating Manual BROSA Type 0210 Shear Force Transducer Version: 05/2020 © 2018 BROSA AG, Tettnang, Germany ................................BROSA AG BROSA Pte Ltd BROSA B.V. BROSA (Nanjing) Co., Ltd. Dr. Klein Straße 1 25 Lorong Kilat #02-01 Galliershof 38 Jinma Lu 3, Maqun Scientific Park, Qixia District...
  • Page 2 BROSA Shear Force Transducer ................................................................Notes ................................................................ © 2018 BROSA AG, Tettnang, Germany Original document 2 / 15...
  • Page 3: Table Of Contents

    Structure and functionality ................5 Information on explosion protection ..............7 Label (nameplate, indication of measuring direction) ......... 7 Advice on the safe handling of BROSA shear force transducers ....... 9 Handling ......................9 Installation and commissioning ............... 10 3.2.1 General information .................
  • Page 4: General Information

    Only the German version of this operating manual represents the original document. 1.1 Safety instructions – Explanation of symbols: WARNING! This symbol indicates dangers that can lead to personal injury and property damage! ................................................................ © 2018 BROSA AG, Tettnang, Germany Original document 4 / 15...
  • Page 5: Description Of The Brosa Shear Force Transducer

    2 Description of the BROSA shear force transducer 2.1 Structure and functionality The BROSA type 0210 shear force transducer is used to measure the force in single-shear connections in or on machines and equipment of all kinds. Figure 1 shows the typical layout:...
  • Page 6 More information can be found in the technical data sheets, which may be obtained free of charge from BROSA................................................................. © 2018 BROSA AG, Tettnang, Germany Original document 6 / 15...
  • Page 7: Information On Explosion Protection

    ................................2.2 Information on explosion protection The type 0210 shear force transducer can be optionally obtained in an intrinsically safe design for use in environments with explosion hazards. This can be done with the 2-wire technique using the ExDANGmicro2W*** amplifier. The following specifications apply:...
  • Page 8 BROSA Shear Force Transducer ................................................................Figure 3: Nameplate positions, measuring direction The measuring direction is indicated on the front side with an arrow (Figure 3, 2)................................................................. © 2018 BROSA AG, Tettnang, Germany Original document 8 / 15...
  • Page 9: Advice On The Safe Handling Of Brosa Shear Force Transducers

    The analysis of an erroneous measurement can result in personal injury or material damage. WARNING! Despite their sturdy design, BROSA shear force transducers may not be used for any other than the intended purpose (see. Section 2.1). Improper use can result in dangers to the life and limb of the user or third parties and/or impairment of the device in which the shear force transducer is implemented or other property.
  • Page 10: Installation And Commissioning

    BROSA shear force transducers must be secured against falling. Do not throw sensors! Use as a tool (e.g. striking, slotting or lever tool) is not permitted; it can cause damage to the sensor and thus falsify the measurement results.
  • Page 11: Additional Information For Operation In Areas Subject To Explosion Hazards

    If it is connected outside an area subject to explosion hazards, it must be in line with the general requirements for electrical equipment. 3.2.2.1 Type 0210 in an intrinsically safe version The sensors with ExDANGmicro2W*** amplifier must be installed according to the following specifications: ................................
  • Page 12 The laying of the connection cable with the amplifier type ExDANGmicro2W_* B2 and type ExDANGmicro2W_* B4 requires protection against damage and tensile load, guaranteed by proper installation. The complete list of possible amplifier configurations can be found in the certificate................................................................. © 2018 BROSA AG, Tettnang, Germany Original document 12 / 15...
  • Page 13: Operation And Maintenance

    BROSA shear force transducers emit neither airborne acoustic noise nor non-ionising radiation. Operation of BROSA shear force transducers is permitted only within the parameters and properties given in the technical data sheets and on the nameplate. These are, among others:...
  • Page 14: Maintenance

    ................................3.3.2 Maintenance In its capacity as a sensor, BROSA shear force transducers are maintenance-free. As load- transmitting elements, however, they are subject to mechanical stress, requiring regular inspections of the fault-free state of each shear force transducer. The intervals between inspections depend on the intensity of use and must be determined by the end-user.
  • Page 15: Disposal

    If necessary, the sensor must be cleaned. WARNING! BROSA shear force transducers contain traces of environmentally hazardous substances. This is also true of the impurities created during use. Contamination of the environment by these substances is to be prevented.

Table of Contents