Page 1
cod. 31876500 INSTRUCTION MANUAL GAS PASTA COOKER (Original instructions) Attention: read the instructions before using the appliance.
Page 2
These types of appliances are designed for commercial applications such as restaurant kitchens, cafeterias, canteens, hospitals and businesses such as bakeries, butcher shops, etc., but not for the continuous mass production of food. The appliances require that some precautions are made during the installation, positioning and/ or fixing and connection to the mains.
Page 3
3 | | TP_700_80 TP_900_80 regolazione aria - air adjustment réglage de l’air - luftregelung regulación aire - luchtregulatie regulação do ar - βάνα ρύθ ιση αέρα seřízení vzduchu - regulácia vzduchu levegőszabályozó - luftregulering justering av luft - luftreglering regulacja powietrza - reglare aer MODEL: ITALY...
Page 4
MOD. N°: BURNERS Hz: 50/60 PASTA COOKER BURNER PASTA COOKER BURNER PASTA COOKER BURNER LXG9CP - SG9CP - CPG - SG7CP G6CP6 G9CP Rated output per burner Reduced power per burner Primary air Ø Pilot Gas type Burner Ø Injectors Ø...
Page 11
| 11 Instruction manual Dimensions Technical data Specific instructions...
Page 12
12 | MOD. N°: GAS PASTA COOKER - SERIES PLUS 600 Hz: 50/60 Dim.: (LxWxH) Model Description work surface (h total) G6CP6 Gas pasta cooker with cabinet mm 600x600x900 (1020 GAS PASTA COOKER - SERIES MACROS 700 Dim.: (LxWxH) Model Description work surface (h total) CPG40E...
Page 14
14 | MOD. N°: The units are in conformity with the European regulations, directives and standards: Reg. 1935/2004/CE Regulations governing materials and items in contact with food products Hz: 50/60 Reg. 2016/426/UE Regulation on appliances burning gaseous fuels 2014/35/UE Low voltage 2014/30/UE EMC (electromagnetic compatibility) 2011/65/UE...
| 15 SPECIFIC INSTRUCTIONS ATTENTION! The figures in this chapter can be found in the initial pages of this manual. APPLIANCE DESCRIPTION - building regulations and local fire prevention measures; Sturdy steel structure with 4 height-adjustable - accident prevention regulations in force; feet.
Page 16
16 | MOD. N°: comfortable. available locally. If not, adapt the appliance to the gas family or Hz: 50/60 ELECTRICAL CONNECTION group required (see the paragraph titled “Running the appliance on other types of gas”). Carry 1) If it is not present, install a disconnector switch out the start-up according to the Operating near the equipment with a magneto-thermal Instructions.
Page 17
| 17 connected equipment. Check that the gas supply doors or by removing the control panel. pipes are adequate. Remove the nozzles and replace them with suitable ones according to the BURNERS table. Be careful to Checking the pilot light keep and assemble the seal gasket, if any.
Page 18
18 | MOD. N°: - After replacing the pilot nozzle, retighten the and temperature. nut, pressing the biconical coupling (N. 14) with - When running the appliance for the first time, Hz: 50/60 the relevant biconical coupling (N. 15). properly clean the tanks and the drilled boards with warm water and detergent to eliminate the Primary air control (fig.
| 19 BY THE MANUFACTURER. The parts must be re- water loading tap a little open to allow for the placed by authorized personnel only! elimination of starch through the overflow hole For a few models, it is sufficient to remove the pan- and to keep the right level of water in the tank.
Page 20
20 | MOD. N°: with other metals or alloys that might leave traces of rust. Hz: 50/60 For the same reason, try to avoid touching the ap- pliance with anything made of iron. Do not use steel wool pads or stainless steel brushes as they could cause rust and may cause damage through scratches.