Advertisement

Quick Links

www.evolu.health
INSTRUCTION MANUAL
BLOOD PRESSURE
the best reason to take care of yourself
MONITOR
{
YES, YOU
Model: DBP-6177
GB
Instruction manual
DE
Gebrauchsanweisung
RU
Инструкция по применению
EE
Kasutusjuhend
LV
Lietošanas instrukcija
LT
Naudojimo instrukcija
MD/RO
Manual de instrucțiuni
GE
გამოყენების სახელმძღვანელო
}
GB
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DBP-6177 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EVOLU DBP-6177

  • Page 1 Model: DBP-6177 Instruction manual Gebrauchsanweisung Инструкция по применению www.evolu.health Kasutusjuhend Lietošanas instrukcija Naudojimo instrukcija MD/RO Manual de instrucțiuni გამოყენების სახელმძღვანელო INSTRUCTION MANUAL BLOOD PRESSURE MONITOR YES, YOU the best reason to take care of yourself...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ..................SAFETY NOTICE ..................DEVICE ILLUSTRATION ................ IMPORTANT TESTING GUIDELINES ..........QUICK START ....................DEVICE OPERATION ................BATTERY INSTALLATION ..............SYSTEM SETTINGS ................APPLYING THE ARM CUFF ..............TESTING ......................POWER OFF ....................MEMORY CHECK ..................MEMORY DELETION ................
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing the DBP-6177 Blood Pressure Monitor. The device has been constructed using reliable circuitry and durable materials. Used properly, this device will provide years of satisfactory use. This device is intended for non-invasive measuring an adult individual’ s systolic, diastolic blood pressure and heart rate using the oscillometric method.
  • Page 4 CAUTION Individuals with serious circulation problems may experience discomfort. Consult your physician prior to use. Contact your physician if test results regularly indicate abnormal readings. Do not attempt to self-treat these symptoms without consulting your physician first. Product is designed for its intended use only. Do not misuse in any way. Product is not intended for infants or individuals who cannot express their intentions.
  • Page 5 Important Instructions Before Use 1. Do not confuse self-monitoring with self-diagnosis. Blood pressure measurements should only be interpreted by a health professional who is familiar with your medical history. 2. Contact your physician if test results regularly indicate abnormal readings. 3.
  • Page 6 20. The system might produce incorrect readings if stored or used outside the manufacturer’s specified temperature and humidity ranges. 21. Do not use the device near strong electrical or electromagnetic fields generated by cell phones or other devices, they may cause incorrect readings and interference or become interference source to the device.
  • Page 7: Device Illustration

    DEVICE ILLUSTRATION Monitor Unit “MEM” Button “START/STOP” Button “SET” Button USB Adapter Jack...
  • Page 8 Arm Cuff Arm Cuff Air Plug Air Tube Display Group2 Group1 Systolic Blood Pressure Low Battery Indicator Arm Shake Indicator Cuff Loose Indicator WHO Blood Pressure Clas- sification Indicator Diastolic Blood Pressure Last 3 Tests Average Irregular Heartbeat Indicator Pulse Rate Time Heart Rate Indicator Date...
  • Page 9 Contents 1. Monitor Unit 2. User Manual 3. Arm Cuff 4. Storage Case 5. 3 new AAA alkaline batteries 6. 2MOPP Medical AC Adapter (DC 5.0 V,1000 mA) (recommended, not provided)
  • Page 10: Important Testing Guidelines

    IMPORTANT TESTING GUIDELINES 1. Avoid eating, exercising, and bathing for 30 minutes prior to testing. 2. Sit in a calm environment for at least 5 minutes prior to testing. 3. Do not stand while testing. Sit in a relaxed position while keeping your arm level with your heart. 4.
  • Page 11 3. Remove thick clothing from the arm area. 4. Rest for several minutes prior to testing. Sit down in a quiet place, preferably at a desk or table, with your arm resting on a firm surface and your feet flat on the floor. (See Figure C ) Figure C 5.
  • Page 12: Device Operation

    DEVICE OPERATION BATTERY INSTALLATION Slide the battery cover off as indicated by the arrow. Install 3 new AAA alkaline batteries according to polarity. Close battery cover. AC Adapter jack is on the back side of the monitor. Medical AC adapter (DC 5.0 V, 1000 mA) can be used with the device (recommended, not provided).
  • Page 13: System Settings

    SYSTEM SETTINGS With power off , press “SET” button to activate System Settings. The Memory Group icon flashes 1. Select Memory Group While in the System Setting mode, you may accumulate test results into 2 diff erent groups. This allows multiple users to save individual test results (up to 150 memories per group.) Press “...
  • Page 14 3. Time/Date setting Press the “SET” button again to confirm the current month. Continue setting the date, hour, and minute in the same way. 4. Time formats Press the “SET” button is pressed, and it will lock in your selection and continue in succession for 12/24 hours.
  • Page 15: Applying The Arm Cuff

    APPLYING THE ARM CUFF 1. Firmly insert air plug into opening located on left side of monitor unit. 2. With sticky nylon section facing outward, insert end of cuff underneath metal ring of cuff . 3. Fasten cuff about 1-2cm (0.4-0.8’’) above the elbow joint. For best results apply cuff to bare arm and keep level with heart while testing.
  • Page 16: Testing

    TESTING 1. Power On Press and hold “START/STOP” button to turn the device on. The LCD screen will appear for one second as device performs a quick diagnosis. Note: Device will not function if residual air from previous testing is present in cuff .
  • Page 17 2. Testing After cuff inflation, air will slowly rise as indicated by the corresponding cuff pressure value. A flashing “ “ will appear simultaneously on screen signaling heart beat detection. Note: Keep relaxed during testing. Avoid speaking or moving body parts.
  • Page 18: Power Off

    Irregular Heartbeat Indicator If the device detects an irregular heart rhythm two or more times during the measuring process, the Irregular Heartbeat Symbol “ IHB “appears on screen along with measurement results. Irregular heartbeat rhythm is defined as rhythm that is either 25% slower or faster than the average rhythm detected while measuring systolic blood pressure and diastolic blood pressure.
  • Page 19: Memory Check

    Last 3 Tests Average With power off , press the “MEM” button to activate screen display. After the device performs a self-diagnosis, the screen will display the average test results from the last 3 readings of the last group used. The “AVG” symbol will appear along with the corresponding WHO Blood Pressure Indicator.
  • Page 20: Memory Deletion

    MEMORY DELETION Memory for a selected group may be deleted while in Memory Check mode. Press and hold the “SET“ button for approximately 3 seconds to delete all memory records from the selected group and then transfer into testing mode. Press the “START/STOP” button to turn the device off . Note: Memory cannot be recovered once it has been deleted.
  • Page 21 Static Pressure Measurement In the power-down state, press and hold the “START/STOP” button, and then install the batteries. Until the LCD screen is full, release the “START/STOP” button. When the LCD screen displays the double zero, the blood-pressure meter is in a static state. Software version is displayed: 10 is a software version in the figure.
  • Page 22: Troubleshooting

    TROUBLESHOOTING Abnormal phenomenon Cause analysis Processing method The armband is tied too tight or too loose, Or the arm strap is tied Roll the armband correctly incorrectly Move the arm during measure- Stay quiet, keep your arm ment or Electronic sphygmoma- steady, and do not move the nometer device...
  • Page 23: Blood Pressure Information

    BLOOD PRESSURE INFORMATION Blood Pressure Blood pressure is the force of blood pushing against the walls of arteries. It is typically mea- sured in millimeters of mercury (mmHg.) Systolic blood pressure is the maximum force exerted against blood vessel walls each time the heart beats. Diastolic blood pressure is the force exerted on blood vessels when the heart is resting between beats.
  • Page 24 WHO Blood Pressure Classification Indicator The DBP-6177 is equipped with a classification indicator based on established guidelines from the World Health Organization. The chart below (marking on the monitor) indicates test results. Normal : Blood Pressure Classification Indicator...
  • Page 25 Health Reminder Hypertension is a dangerous disease that can aff ect the quality of life. It can lead to a lot of problems including heart failure, kidney failure, and cerebral hemorrhaging. By maintaining a healthy lifestyle and visiting your physician on a regular basis, hypertension and relative diseases are much easier to control when diagnosed in their early stages.
  • Page 26: Blood Pressure Q&A

    BLOOD PRESSURE Q&A Q: What is the diff erence between measuring blood pressure at home or at a professional healthcare clinic? A: Blood pressure readings taken at home are now seen to give a more accurate account as they better reflect your daily life. Readings can be elevated when taken in a clinical or medi- cal environment.
  • Page 27: Maintenance

    MAINTENANCE 1. Avoid dropping, slamming, or throwing the device. 2. Avoid extreme temperatures. Do not expose device directly under sunshine. 3. When cleaning the device, use a soft fabric and lightly wipe with mild detergent. Use a damp cloth to remove dirt and excess detergent.
  • Page 28 4. Cuff Cleaning: Do not soak cuff in water! Apply a small amount of rubbing alcohol to a soft cloth to clean cuff ’ s surface. Use a damp cloth (water-based) to wipe clean. Allow cuff to dry naturally at room temperature. The cuff must be cleaned and disinfected before use between diff erent users.
  • Page 29: Specifications

    SPECIFICATIONS Product Description Arm-type Fully Automatic Blood Pressure Monitor Model DBP-6177 Display LCD Digital Display. Size: 66.4 mm x 43. 1 mm (2.61” x 1.70”) Measurement Method Oscillometric Method Systolic Pressure 60mmHg ~ 260mmHg Diastolic Pressure 30mmHg ~ 200mmHg Measurement...
  • Page 30 Temperature +10°C ~ +40°C; (50°F ~ 104°F) Operating Environment Humidity 15 % RH ~ 93 % RH; Pressure 800 hPa ~ 1060 hPa Temperature -25°C ~ 55°C; (-13°F ~ 131°F) Storage Environment Humidity ≤ 93 % RH Temperature -25°C ~ 55°C; (-13°F ~ 131°F) Transport Environment Humidity ≤...
  • Page 31: Electromagnetic Compatibility Information

    ELECTROMAGNETIC COMPATIBILITY INFORMATION The device satisfies the EMC requirements of the international standard IEC 60601-1-2. The requirements are satisfied under the conditions described in the table below. The device is an electrical medical product and is subject to special precautionary measures with regard to EMC which must be published in the instructions for use.
  • Page 32 Table 2 Guidance and declaration of manufacturer-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. IMMUNITY test IEC 60601 Compliance Electromagnetic environment...
  • Page 33 Table 2 (continued) Guidance and declaration of manufacturer-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. IMMUNITY test IEC 60601 Compliance Electromagnetic environment test level...
  • Page 34 Table 3 Guidance and declaration of manufacturer-electromagnetic immunity Nowadays, many RF wireless equipments have being used in various healthcare locations where medical equipment and/or systems are used. When they are used in close proximity to medical equipment and/or systems, the medical equipment and/or systems’ basic safety and essential performance may be aff ected.
  • Page 35 Table 4 Recommended separation distances between portable and mobile RF communications equipment and the device The device is intended for use in an electromagnetic environment in which radiated therefore disturbances are controlled. The customer or the user of the device can help prevent electro- magnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment.
  • Page 36: Additional Notes

    ADDITIONAL NOTES Important Instructions Before Use 1. WARNING: Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally 2.
  • Page 37 verify the accuracy. If the accuracy deviation is large, please contact the manufacturer to recalibration. 10. Mechanical strength and resistance to heat. The resistance to heat will be retained by device during the EXPECTED SERVICE LIFE of the ME EQUIPMENT. 11.
  • Page 38 EVOLU® is a registered Trade Mark of FORANS International AG, Switzerland JOYTECH Healthcare Co., Ltd. No.365, Wuzhou Road, Y uhang Economic Development Zone,Hangzhou City, 311100 Zhejiang, P.R. China E-mail: info@sejoy.com Shanghai International Holding Corp. GmbH (Europe) Eiff estrasse 80, 20537 Hamburg, Germany Phone: +49 40 2513175, E-mail: shholding@hotmail.com...
  • Page 39: Warranty Card

    WARRANTY CARD Serial Nr. Name of customer Date of purchase Contact number Address Sale company Contact number Address of sales company WARRANTY CARD Serial Nr. Name of customer Date of purchase Contact number Address Sale company Contact number Address of sales company...
  • Page 40 The period of host free for warranty service is 2 years. During the warranty period, we will decide to repair or replace damaged parts or accessories according to the case. The warranty covers all parts of the blood pressure monitor except the cuff , adapter and batter- ies.

Table of Contents