Download Print this page

Advertisement

Quick Links

CT-E9
User Guide
Rev: 1.0.2211.0
Copyright © 2022 Pixel Technologies Pty Ltd

Advertisement

loading

Summary of Contents for Pixel CT-E9

  • Page 1 CT-E9 User Guide Rev: 1.0.2211.0 Copyright © 2022 Pixel Technologies Pty Ltd...
  • Page 2 Description The CT-E9 universal input encoder provides an interface to encode li controller signals and communicate these signals to Pixel Technologies Devices using our DataBus protocol. Features: Discrete, Binary and Gray code input encoder modes Ÿ Pixel Technologies DataBus output protocol Ÿ...
  • Page 3 Advanced Parameter Setup You can connect to the CT-E9 via a network or directly using your PC or laptop to access the built-in web server. Accessing the web server allows for extended parameter setup. It also includes Live Data view allowing the user to validate the li controller inputs and messages being received.
  • Page 4: Specifications

    10V DC (min) - 30 VDC (max) Input Protocols Discrete, Binary, Gray code Output Interface RS-485 Output Protocols Pixel & Design-Com - Mode 2 & 3 Pixel DataBus Length 400m, maximum of 128 nodes Ethernet 10/100Base-TX Status Indica on Status (RGB LED), Ethernet Opera ng Temperature 0 - 50°C...
  • Page 5 ARR OWS GONG/LANTERN DATA/PWR A 0V V+ DIP switches 7 - 8 are not applicable and reserved. Ethernet Web Server access & Network Connec vity Pixel Devices (DataBus) 10.100.1.150 Orange LED Green LED Displays & stand-alone DVA units LINK Ac vity Recommended Cabling: Shielded Twisted Pair Belden 8723 or equivalent.