Description The CT-E9 universal input encoder provides an interface to encode li controller signals and communicate these signals to Pixel Technologies Devices using our DataBus protocol. Features: Discrete, Binary and Gray code input encoder modes Ÿ Pixel Technologies DataBus output protocol Ÿ...
Page 3
Advanced Parameter Setup You can connect to the CT-E9 via a network or directly using your PC or laptop to access the built-in web server. Accessing the web server allows for extended parameter setup. It also includes Live Data view allowing the user to validate the li controller inputs and messages being received.
10V DC (min) - 30 VDC (max) Input Protocols Discrete, Binary, Gray code Output Interface RS-485 Output Protocols Pixel & Design-Com - Mode 2 & 3 Pixel DataBus Length 400m, maximum of 128 nodes Ethernet 10/100Base-TX Status Indica on Status (RGB LED), Ethernet Opera ng Temperature 0 - 50°C...
Page 5
ARR OWS GONG/LANTERN DATA/PWR A 0V V+ DIP switches 7 - 8 are not applicable and reserved. Ethernet Web Server access & Network Connec vity Pixel Devices (DataBus) 10.100.1.150 Orange LED Green LED Displays & stand-alone DVA units LINK Ac vity Recommended Cabling: Shielded Twisted Pair Belden 8723 or equivalent.