Summary of Contents for GBP Microclean

  • Page 1 MANUAL MANUAL MANUAL -Vaskemaskiner for maskin- og motordeler -Vaskemaskiner for maskin- og motordeler Cleaners for factory tools and small parts Microclean Microclean Maxiclean Maxiclean Microclean Masterclean Masterclean Maxiclean Masterclean...
  • Page 2: Table Of Contents

    MASTERCLEAN INTRODUCTION SAFETY FUNCTION INSTALLATION MICROCLEAN Assembly instructions FUNCTION CLEANING INSTRUCTIONS INSTALLATION Assembly instructions MAINTENANCE How to change liquid CLEANING INSTRUCTIONS How to change pump gasket How to change pump MAINTENANCE How to change power cord How to change liquid...
  • Page 3: Introduction

    GBP does not take responsibility for personal injury or damage on the cleaner, if instructions are not followed. Make sure to read the instruction manual before unpacking, installing or using this cleaner.
  • Page 4: Safety

    SAFETY The warning labels in this manual stand for the following: Negligence in the following instruction in this manual might be life threatening. Negligence in the following instruction in this manual might lead to personal injury. Negligence in the following instruction in this manual might lead to damage to the cleaner.
  • Page 5: Microclean Function

    MICROCLEAN (Part. N . 36-180-2101) FUNCTION MICROCLEAN can easily be fitted to the wall or placed on a workbench. It is designed for manual cleaning using a spray gun. The liquid is recycled automatically and cleaned using sedimentation. Ventilation hose is available as an accessory.
  • Page 6: Cleaning Instructions

    • The liquids flash point • Do not place the cleaner in wet ° or humid rooms. must exceed 70 This may cause flash over! If not, it may cause a fire! CLEANING INSTRUCTIONS 1. Open the cover and put the parts, which need to be cleaned on the wash board.
  • Page 7: How To Change Pump Gasket

    How to change the pump gasket Unplug the machine from the power supply! Empty the liquid, see: 'How to change the liquid'. Unscrew the front plate and loosen the hose clip. Loosen the two screws underneath the ground plate and lift up the pump. Loosen the pump block and unscrew the pump wheel.
  • Page 8: Maxiclean Function

    MAXICLEAN (Part. N . 36-181-2101) FUNCTION MAXICLEAN has two cleaning systems, which can be used separately or integrated. The parts can be cleaned either in a closed area, where the liquid is automatically sprayed on the part by three nozzles or placed on a wash board and cleaned manually with a spray-gun.
  • Page 9: Cleaning Instructions

    • The liquids flash point • Do not place the cleaner in wet must exceed 70°C. or humid rooms. If not, it may cause a fire! This may cause flash over! • Improper supplements such as thinner or trichloroethylene may cause damage to the pump and hoses.
  • Page 10: Maintenance

    MAINTENANCE • A bad cleaning result may be caused by: • The liquid needs to be replaced. • The pump gasket needs to be replaced. .The pump needs to be replaced. The nozzles need to be cleaned • A leakage is most likely caused by a damaged pump gasket. How to change the liquid 1.
  • Page 11: Spare Parts

    SPARE PARTS 38-100-0001 Brush 38-110-0001 Pump 38-102-0001 Gasket 38-103-0001 Net strainer 38-104-0001 Nozzle 38-105-0001 Spray gun with hose 38-107-0001 Main switch ACCESSORIES 36-186-9001 Wash basket 420x270x190 mm 36-188-9001 Wash basket 250x120x90 mm 36-191-0001 Castor kit 36-193-0001 Ventilation hose TECHNICAL SPECIFICATION Number of nozzles Spray gun with brush Pump capacity/min...
  • Page 12: Masterclean Function

    MASTERCLEAN (Part. n . 36-182-2101) FUNCTION MASTERCLEAN has two cleaning systems, which can used separately or integrated. The parts can be cleaned either in a closed area, where the liquid is automatically sprayed on the part by six nozzles or placed on a wash bench and cleaned manually with a spray-gun.
  • Page 13: Cleaning Instructions

    • Do not place the cleaner in • Improper supplements such as wet or humid rooms. thinner or trichloroethylene may This may cause flash over. cause damage to the pump and hoses. • Do not place the cleaner in • Improper supplements such as wet or humid rooms.
  • Page 14: Maintenance

    MAINTENANCE A bad cleaning result may be caused by: • The liquid needs to be replaced. • The pump gasket needs to be replaced. • The pump needs to be replaced. • The nozzles need to be cleaned A leakage is most likely caused by a damaged pump gasket. How to change the liquid 1.
  • Page 15: Accessories

    SPARE PARTS 38-100-0001 Brush 38-110-0001 Pump 38-102-0001 Pump gasket 38-103-0001 Net strainer 38-104-0001 Nozzle 38-106-0001 Spray gun with hose 38-107-0001 Switch manual wash 38-108-0001 Switch automatic wash 36-183-0001 Timer ACCESSORIES 36-186-9001 Wash basket 420x270x190 mm 36-188-9001 Wash basket 250x120x90 mm 36-193-6001 Ventilation hose TECHNICAL SPECIFICATION...