Dell P154G Technical Manualbook page 36

Hide thumbs Also See for P154G:
Table of Contents

Advertisement

Table 49. Tower - Military specifications (continued)
Test Category
Operating altitude test
Non-operating high temperature test
Operating high temperature test
Non-operating low temperature test
Operating low temperature test
Humidity test
Sand and dust - Blowing dust
Operating Vibration
Non-Operating Vibration - Minimum integrity test
Shock - Functional shock
Shock - Transportation shock
Shock - Transit drop
Shock - Crash hazard shock
Shock - Bench handling
36
Engineering specifications
Test Method
Test Parameters
Method 500.6
Test specification:
Procedure II
● Altitude: 15,000 ft
● Temperature: 21°C
Method 501.7
Test specification:
Procedure I
● High temperature cycles (33°C–71°C),
climatic category A1 - Hot dry
● Duration: 7 cycles, Non-Operating
Method 501.7
Test specification:
Procedure II
● Temperature: 32°C–49°C
● Duration: 5 cycles, Operating
Method 502.7
Test specification:
Procedure I -
● Temperature: -51°C
Storage
● Duration: 24 hours
Method 502.7
Test specification:
Procedure II -
● Temperature: -29°C
Operation
● Duration: 24 hours
Method 507.6
Induced B3
Procedure I
● Duration: Hot-humid, 24 hours exposure
Induced B3, Non-operating
Method 510.7
Test specification:
Procedure I
● Relative humidity: 30%
● Temperature: 60°C
● Air flow velocity: 1.5 m/s to 8.9 m/s
Method 514.8
Test specification:
Procedure I,
● 5 Hz–500 Hz, 1.17 Grms
Category 4
● Duration: 1 hr on Bottom, Left, and Back
side
Method 514.8
Test specification:
Procedure I,
● 20 Hz–2000 Hz, 7.69 Grms
Category 24
● Duration: 1 hr/axis
● Axis: X, Y, and Z
Method 516.8
185 g, 2 ms Half Sine 1 shock/axis/direction
Procedure I
for a total of 6 shocks
NOTE:
Method 516.8
to replace Saw Tooth Waveform in
Procedure II
accordance with MIL SPEC.
Method 516.8
Modified: 26 X 30-inch drops onto 2-inch of
Procedure IV
plywood over non-yielding surface.
Method 516.8
185 g, 2 ms Half Sine 2 shock/axis/direction
Procedure V
for a total of 12 shocks
NOTE:
Method 516.8
replace MIL-STD-8108, Method 516.8,
Procedure VI
Procedure V, Table 516.8-XIII
Dell to use Half Sine Waveform
Dell to use noted test to

Advertisement

Table of Contents
loading

This manual is also suitable for:

Precision 5470

Table of Contents