Page 2
(When it is damaged, it can cause a fire.) Do not touch the power cord with wet hands. (It can cause an electric shock.) Do not use the damaged power cord and outlet. (It can cause an electric shock and a fire.) N-BIOTEK l NB-901M (Ver. 2021)
To prevent water and experiment material from going into the control panel during the experiment, make sure to clean the control panel with a dry cloth. (It can cause an electric leakage and a fire.) N-BIOTEK l NB-901M (Ver. 2021)
Page 4
When you see smoke comes out from the product or smell something is burning or see any other strange symptoms, you have to pull out the power cord and stop using it. (It can cause an electric shock and a fire.) N-BIOTEK l NB-901M (Ver. 2021)
±2℃ Temp. Controller Digital P.I.D Controller Temp. Indicator Digital Display (LED) Dimension (In) 500x500x600Hmm, 150 Liter Dimension (Out) 660x780x1100Hmm Material (In) Stainless Steel (STS430) Material (Out) SCP-1 (Powder Coating) Circulation Fan 180W Blower Fan Shelves N-BIOTEK l NB-901M (Ver. 2021)
Page 6
3. Configuration and Control Panel 3.1 Configuration FRONT BACK DOOR HAND SIGHT GLASS FAN MOTOR CONTROL PANEL RUBBER FEET 3.2 Control Panel N-BIOTEK l NB-901M (Ver. 2021)
Page 7
Movement of the place for temp., timer, parameter Shift L Button setting (Left) Movement of the place for temp., timer, parameter Shift R Button setting (Right) Setpoint Increase Button Setting value change DSP (AUTO-TUNE) Button On/Off Auto-tune N-BIOTEK l NB-901M (Ver. 2021)
Page 8
• The change value can be used 99 hour 59 min, or 99 day, 23 hour. • If the setting is finished, push release after pressing the SET button. It will come back as normal statement sign. N-BIOTEK l NB-901M (Ver. 2021)
Page 9
• WAIT_ZONE function refers to a function that delays timer operation until the current temp. reaches the set timer start temperature. • From END state, heater control output turns off. • During normal statement, the temp. controls by digital PID. N-BIOTEK l NB-901M (Ver. 2021)
5) If you press SET button over 5 sec. in parameter setting mode, it goes back to normal statement with beep sound. 6) If you don’t input order over 1min. in parameter mode, it goes back to normal statement. N-BIOTEK l NB-901M (Ver. 2021)
4) I (INTEGRAL) : It is fixing value of integral calculus - Setting range : 0 – 6999 5) D (DIFFERENTIAL) : It is fixing value of differential calculus - Setting range : 0 – 6999 N-BIOTEK l NB-901M (Ver. 2021)
N-BIOTEK, whichever is sooner as indicated in above table. This period is proved by serial no. 3. N-BIOTEK will not be responsible of free warranty service for the faulty caused by user’s improper operation, excessive use, use of incorrect voltage & frequency, storage in wrong environment mentioned in Manual.