Cleode ZLight User Manual

Zigbee device for electric light bulbs

Advertisement

Quick Links

User
Manual
CLEODE - Headquarter: 3, rue Thomas Edison - 22300 LANNION – France
T. +33 (0)2 96 48 68 18 - F. +33 (0)2 96 48 19 11
SA au capital de 167 200 € - 450 570 767 RCS Saint Brieuc
ZLight
ZigBee®device
for electric light bulbs
Reference : UM_ZLight_20110922_001_02_00
Revision: 2.0
date : 10/08/2015
Status : Approved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZLight and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cleode ZLight

  • Page 1 Status : Approved Reference : UM_ZLight_20110922_001_02_00 CLEODE - Headquarter: 3, rue Thomas Edison - 22300 LANNION – France T. +33 (0)2 96 48 68 18 - F. +33 (0)2 96 48 19 11 SA au capital de 167 200 € - 450 570 767 RCS Saint Brieuc...
  • Page 2 In order to invoke the warranty, the buyer must immediately send written notice to CLEODE of the flaws that it attributes to the device. It must enable CLEODE to have access to the device to observe these defects and repair them. The warranty provided by CLEODE is strictly limited to the equipment provided and shall only have for effect the replacement or repair, at CLEODE’s expense, on...
  • Page 3 Table of revision Version Author(s) Version description Date CLEODE Initial version 09/15/2011 CLEODE Document validation 09/21/2011 CLEODE Update for new hardware version 10/05/2015 CLEODE Document validation 10/08/2015 User manual : ZSHADE CLEODE page...
  • Page 4 Reference documents N° Document Description ZigBee_Cluster_Library_Public Specification of the ZigBee® Cluster Library ZigBee _Home_Automation Specification of the Home Automation profile ZigBee _Specification Specification of the ZigBee® standard User manual : ZSHADE CLEODE page...
  • Page 5: Table Of Contents

    IV.1 O VERVIEW IV.2 A PPLICATION IV.2.1 D ESCRIPTION OF THE APPLICATION IV.2.2 D ESCRIPTION OF CLUSTERS IV.2.2.1 Cluster Basic IV.2.2.2 Cluster Identify IV.2.2.3 Cluster Group IV.2.2.4 Cluster Scenes IV.2.2.5 Cluster On/Off V. TECHNICAL ISSUES User manual : ZSHADE CLEODE page...
  • Page 6 ........................7 IGURE LOBAL VIEW OF THE HADE DEVICE 2 : P ............................... 10 IGURE OWER WIRING ..........................11 IGURE WIRING OF ELECTRICAL BULBS ......................11 IGURE WIRING OF A SWITCH FOR ROLLER SHUTTER User manual : ZSHADE CLEODE page...
  • Page 7: Overview Et Technical Characteristics

    I. Overview et technical characteristics I.1 Overview The ZLight product is a ZigBee® device for electric light bulb management. It can be managed in different ways:  On reception of ZigBee® command (on the On/Off Light cluster)  Or by switches.
  • Page 8: Technical Characteristics

    ZigBee® Pro 2007 16 channels Radio range About 150 m (indoor) Operating temperature +5 à +45 °C Electrical supply 110-230V / 50-60Hz Maximum current capability Measurement 44 x 44 x 25 mm Number of managed light bulbs User manual : ZSHADE CLEODE page...
  • Page 9: Quick Start

    Rapid implementation procedure: 1) Install the ZLight product (For more details, refer to chapter III.1). 2) Pair the ZLight product in the ZigBee® network (For more details, refer to chapter III.2). 3) The product is operational in your ZigBee® network.
  • Page 10: Procedures

    3A. III.1.1 Power wiring The ZLight must be supplied with a mains voltage between 110V and 230V with a frequency between 50 Hz and 60 Hz. The wiring must be carried out as shown in the image below: ...
  • Page 11: Iii.1.3 Wiring Of Switches

    Figure 3 : wiring of electrical bulbs III.1.3 Wiring of switches It is possible to manage the ZLight product by a wired switch for electric bulbs To use a switch, you must connect it as shown below:  : connect this output to the common inputs of all switches (red wire) ...
  • Page 12: Iii.2 Pairing Of The Product For The First Time

    1) Allow the addition of a ZigBee® device in your network (see the user manual of your coordinator). 2) At power-up, the ZLight product tries to associate and blinks twice. 1) If a coordinator is present and allows the ZLight to join, the ZLight indicator will light for 2 seconds then turns off.
  • Page 13: Software Interface

    Scenes (0x0005) On/Off (0x0006) IV.2.2 Description of clusters Here is a brief description of the clusters and the attributes implemented in the ZLight product. For more precision on the functioning thereof, please refer to the document [1]. IV.2.2.1 Cluster Basic This cluster hosts the version information, name of manufacturer, model of the object, etc.
  • Page 14: Iv.2.2.2 Cluster Identify

    This cluster is used to manage scenes incorporating the ZLight product. Attribut Attribut ID 0x0000 NameSupport IV.2.2.4 Cluster Scenes This cluster is used to memorize the names of the groups to which the ZLight product belongs. Attribut Attribut ID SceneCount 0x0000 CurrentScene 0x0001...
  • Page 15: Technical Issues

    I can't associate the ZLight product in my ZigBee® Verify that your coordinator accepts the associations network. and the ZLight is located in radio range of the other ZigBee ® network elements (Coordinator, routers). The ZLight device no longer meets ZigBee® commands Check that the ZLight is always powered.
  • Page 16 The information provided on the label are as follows:  Model,  Year of production,  Reference and Version,  Serial Number. This information may you be requested by the company CLEODE to identify your hardware. User manual : ZSHADE CLEODE page...