1. APPLICATION
THERMOCONT TXP resistance thermometers with a drilled thermo-well case are used as temperature
measurement sensors in industrial process control, especially in the gas industry. The temperature sensors
are suitable for temperature measurement of various gaseous media inside pipelines, tanks, and furnaces.
The heat-sink on the outer protective tube provides accurate measurement independently from the ambient
temperature. The double pipe construction - including the inner and outer tube and well - meets the
mechanical and vibrational protection requirements. Process connection and electrical connection are
provided as detailed below. The cable glands provide sealing for the cables.
The outer protective tube is a drilled thermo-well case made from stainless steel. The cover of the housing
has a chain to prevent misplacing it. The Pt100 temperature sensor can be replaced without removing the
instrument from the process.
2. TECHNICAL DATA
Accuracy class
Type
Material of internal protective
tube
Process connection
Version
Housing material
Cable gland
Cable
Electrical connection
Ingress protection
Process connection
Material
Insertion length
Process pressure
Measuring range
Ambient temperature
Electrical protection
Ex marking
Ex Information
2.1 E
X TEMPERATURE CLASSIFICATION
Temperature class
Max. ambient temperature
Max. medium temperature
2.2 A
CCESSORIES
 User's Manual
 Warranty Card
 EU Declaration of Conformity
2.3 O
RDER CODES
THERMOCONT T X P –
S
P
C
ROCESS CONNECTION
ODE
C
1" NPT
1
Single, 2-wire
M33x2
V
Dual, 3-wire
Single, 4-wire
The order code of the Ex-version ends in "Ex"
(1)
Without cable glands, use glands with protection designation "d" only
(2)
TXP–1–
TXP–4–
Pt100A, class "A" (MSZ EN 60751), as per order code
single, 2-wire
dual, 3-wire
Spring loaded
Ground-independent
Powder-coated aluminum (EN AC – 43100)
M20×1.5 or without cable glands, ½" NPT interior thread
For Ex ia protection type: nickel-plated brass cable gland, or closing bolt;
For Ex d and Ex dia protection types:
Ex d IIC certified cable gland for cable Ø6...Ø12 mm (Ø.236...Ø.472")
Screw type terminal
M33x2, 1" NPT
1.4571 stainless steel
max. 500 mm (19.7"), as per order codes
Max. 80 bar (8 MPa / 1160 psi)
–50...+150 °C (−58...+302 °F)
–30...+80 °C (−22...+176 °F)
II 1 G Ex ia IIB T6...T4 Ga
II 2 G Ex d IIB T6...T4 Gb
II 1/2 G Ex d ia IIB T6...T4 Ga/Gb
U
: 30 V, I
: 140 mA, P
i
i
T6
+65 °C (+149 °F)
+70 °C (+158 °F)
+85 °C (+185 °F)
+100 °C (+212 °F)
/ P
100
ENSOR TYPE
T
C
P
ODE
ROBE LENGTH
"A"
LASS
1
120 mm
4
160 mm
7
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
TXP–7–
single, 4-wire
PTFE
IP67
Class III
: 1,1W, C
= 0, L
= 0
i
o
o
T5
T4
+70 °C (+158 °F)
+135 °C (+275 °F)
Ex
(1)
C
E
ODE
X CERTIFICATE
0
None
1
Ex d ia IIB / ½" NPT
2
Ex ia IIB
3
Ex d ia IIB
4
Ex d IIB
5
6
7
8
C
ODE
0
6
(2)
7
8
9
txp171en22h03 ▪ 1 / 2

Advertisement

loading

Summary of Contents for NIVELCO THERMOCOUNT TXP 1 Series

  • Page 1 Thank you for choosing a NIVELCO instrument. 1. APPLICATION THERMOCONT TXP resistance thermometers with a drilled thermo-well case are used as temperature measurement sensors in industrial process control, especially in the gas industry. The temperature sensors are suitable for temperature measurement of various gaseous media inside pipelines, tanks, and furnaces.
  • Page 2 (Returned Equipment Handling Form) must be filled and enclosed in the parcel. Download it from our website www.nivelco.com. The device must be sent back with a declaration of decontamination. A statement must be provided in the declaration that the decontamination process was successfully completed and that the device is clean from any hazardous substances.

This manual is also suitable for:

Thermocount txp 4 seriesThermocount txp 7 series