Table of contents Table of contents General information........................ 4 About this documentation .................... 4 Other applicable documentation .................. 4 Structure of the safety notes ................... 4 Rights to claim under limited warranty ................ 5 Product names and trademarks.................. 5 Copyright notice ...................... 5 Device structure ........................ 6 Type designation...................... 6 Scope of delivery ...................... 6 Basic device........................ 7...
General information About this documentation General information About this documentation INFORMATION The device is designed for use in industrial and commercial systems and machines in ® combination with a MOVIPRO drive and application controller. ® The functions of the device depend on the characteristics of the MOVIPRO drive and application controller with which the device is operated.
General information Rights to claim under limited warranty 1.3.2 Structure of section-related safety notes Section-related safety notes do not apply to a specific action but to several actions pertaining to one subject. The hazard symbols used either indicate a general hazard or a specific hazard.
Device structure Type designation Device structure Type designation The type designation of the device contains the following data: ® Drive and positioning control MOVIPRO accessories Housing: with high degree of protection for mounting to the machine 1. Generation – HSIR Function type: High-speed infrared interface adapter –...
Device structure Basic device Basic device The following figure shows the design of the device: 28377867915 Infrared interface Mounting lugs HSIR TX status LED X4002: RS485 interface – system bus HSIR RX status LED X4001: RS485 interface – system bus Nameplate The nameplate lists information about the device type. The following figure shows an example of a main nameplate: 27021626649698955 China RoHS-2 marking...
Device structure Functional principle Functional principle INFORMATION The device is equipped with a high-speed infrared interface that transmits data via in- visible laser radiation in laser class 1. The device is an interface adapter and provides 2 communication interfaces for bid- irectional data transmission.
Page 9
Device structure Functional principle 9007227537674635 ® MOVIPRO infrared interface HSIR interface adapter with stationary infrared interface ® MOVIPRO Addendum to the Operating Instructions – HSIR Interface Adapter PZO30A-HSIR-S02-B1...
Mechanical installation Minimum clearance Mechanical installation Minimum clearance During installation, observe the required minimum clearances for connecting cables and plug connectors. Minimum and maximum clearances Data can be transferred if the HSIR interface adapter is located in the optical reception area.
Page 11
Mechanical installation Procedure 3. Fasten the HSIR interface adapter with M4 screws of the appropriate length and washers. X 40 01 X 40 02 28533496459 4. Tighten the screws with a tightening torque of 1.8 to 2 Nm. Addendum to the Operating Instructions – HSIR Interface Adapter PZO30A-HSIR-S02-B1...
Electrical installation Shielding Electrical installation Shielding Observe the following when shielding: • Use shielded power and electronics cables • Connect the shield and make sure it is grounded over a wide area at both ends. When using cables with multiple shielding, you also have to ground the inner shields on both ends over a wide area.
Electrical installation X4002: RS485 interface – system bus X4002: RS485 interface – system bus Function Internal RS485 interface (system bus) Connection diagram Name Function +24V DC 24 V output RS485 data line (-) Reference potential RS485 data line (+) res. Reserved Addendum to the Operating Instructions –...
Operation Status LED Operation Status LED The status LED is located in the area of the inspection window of the device and indi- cates the communication and device states. 5.1.1 HSIR TX status LED State LED Possible cause Measure • The HSIR interface adapter is •...
Page 15
Service Maintenance Service Maintenance The device is maintenance-free. SEW-EURODRIVE does not stipulate any regular maintenance work. However, it is recommended that you regularly check the following parts: • Connection cables: Damaged or fatigued cables must be replaced immediately. • Inspection window: Keep the inspection window clean.
Technical data General Technical data General Basic device Ambient temperature ϑ -25 to +60 °C (non-condensing, no condensation) Climate class EN 60721-3-3, class 3K3 Storage temperature ϑ -25 to +85 °C (EN 60721-3-3, class 3K3) Degree of protection IP55 Mass 0.5 kg Dimensions W × H × D 106.6 × 131 × 37.1 mm HSIR interface General Infrared light pulses Baud rate 115.2 kBaud, 8 data bits, 1 stop bit, no parity bit RS485 interface – system bus...
Technical data Transmission and reception area Transmission and reception area The following diagram shows the width of the transmission/reception area depending on the distance from the device: -40 -35 -30 -25 -20 -15 -10 -5 10 15 20 25 30 35 40 Horizontal/vertical distance to the infrared interface in cm 9007237766288011 Addendum to the Operating Instructions –...