INTRODUCTION AND WARRANTY CONDITIONS 1.1. Introduction LEGUAN LIFTS wants to thank you for purchasing this Leguan access platform. It is the result of Leguan’s long experience in design and manufacturing of access equipment. We ask you that you read and understand the contents of this manual completely before operating the access platform.
Page 5
Warranty is limited to the repair of a faulty access platform without cost at an authorized Leguan service workshop. Warranty period for parts that are changed in connection with the repair will end when the warranty period for the access platform ends. Parts that have been changed in the warranty repair will remain Leguan Lifts’...
Page 6
SUUNNITTELUSSA: EN280:2013 FOLLOWING EUROPEAN HARMONIZED STANDARDS ARE USED WHEN THE MACHINERY WAS DESIGNED: EN280:2013 Teknisen tiedoston on valtuutettu kokoamaan: LEGUAN LIFTS OY Storage address of original documents: Ylötie 10, FI-33470 Ylöjärvi, Finland Ilmoitettu laitos / Notified Body INSPECTA TARKASTUS OY,...
LEGUAN is designed and built in accordance with the international safety standards and MEWP (Mobile Elevating Work Platform) standards. The picture below shows the main parts of this access platform. Leguan 135 on wheels is identical to the machine with tracks, except for the crawler track system.
TECHNICAL SPECIFICATION, LEGUAN 135 Working height, safe working load <140 kg 13,2 m 140 - 230 kg 12,2 m Max. platform height, <140 kg 11,2 m 140 – 230 kg 10,2 m Max. outreach, <140 kg 6,8 m 140 – 230 kg 5,8 m Safe working load, max.
3.2. Set up diagram The minimum distances between support points are shown in the picture below. The minimum dimensions needed to set the outriggers with small outrigger pads are 3650 x 3700 mm (length x width). With large outrigger pads the dimensions are 3800 x 3850 mm (length x width).
7. Always use outriggers 8. Symbol stickers (pictograms) of controls 9. Emergency lowering 10. Residual current device 11. Voltage of electric motor 12. Max. support force 13. Distance from energized electric wires 14. Tie down points 15. Tyre pressure 16. LEGUAN 135 sticker...
SAFETY INSTRUCTIONS The operator must know and follow all safety instructions. The operator must receive sufficient instructions in order to be able to use the lift correctly and safely. This Operators Manual must always be kept in the box on the platform. ATTENTION! In order to prevent unpermitted use of the access platform, take the main battery disconnect key that is located on ground level and the engine ignition key, if fitted, with you after ending...
In order to ensure the safe operation of this access platform the manufacturer has conducted approved tests for the LEGUAN 135 in accordance with the standard EN280:2013 : static stability test in accordance with paragraph 6.1.4.2.1 and dynamic overload tests in accordance with paragraph 6.1.4.3 of...
5.4. Collision hazard Adjust the drive speed so that it is safe with regard to the ground conditions. The operator must follow all regulations concerning the use of safety equipment on the work site. Make sure that there are no overhead obstacles on the work site that could prohibit lifting of the platform, or objects that might cause a collision.
ATTENTION! If the access platform has been in an accident/has broken down, the operation must be stopped immediately. The functions of the access platform must be checked by Leguan service to make sure that they work properly before starting operation again.
CONTROLS 6.1. Controls at platform 6.1.1 Remote-control switches Function of the remote-control switches at platform varies somewhat, depending on model. Functions marked as “option” are not available for all models. 1. Control lever, drive, left side 2. Control lever, slewing 3.
6.1.3 Pairing of remote-control unit If the wireless controlling isn’t working it is possible to pair the remote control with the receiver in the following way. 1. Connect the remote control to the cable. 2. Switch on battery disconnect switch of the machine. 3.
6.1.4 Remote-control display The symbols and indicators on the remote-control display at platform can vary somewhat, depending on model. Symbols that are marked as option are not available for all models. 1. Boom operation indicator (green) 2. Inclination warning indicator (orange) (option) 3.
Page 21
Second main page 1. Voltage of the battery of the machine 2. Ambient temperature sensor reading (option) 3. P1 = pump pressure, P2 = boom pressure (option), P3 = drive pressure (option), P4 = outrigger pressure (option) 4. Radio remote-control symbol 5.
Leguan service. The third service page, with user level password, shows engine/electric motor operating hours, number of using of safety functions override switch, and the date of last operation in relation to total operating hours.
6.2. Controls at ground level 6.2.1 Battery disconnect switch Battery disconnect switch disconnects the circuit from plus line of the battery. When battery disconnect switch is switched off, all low voltage functions except for emergency lowering and GPS device (option) are switched off.
Operating the lower controls: 1. Turn the ignition switch to lower controls position. 2. When lower controls have been chosen, the engine/electric motor can be started and stopped with the buttons on the lower controls panel 3. Boom movement speed can be selected with the 4-stage switch 4.
/ trickle charge 4. Service operation switch. The switch is intended for the use of Leguan service only. It switches on electric motor, when the switch is being pushed down. Allows operation of movements by using the manual control of the valves. A more detailed description on the operation of the switch can be found in the service manual.
6.2.6 Manual pump at pedestal 1. Manual pump and shaft 2. Control valve, platform self-leveling 3. Control valve, jib boom 4. Control valve, telescoping boom 5. Control valve, slewing 6. Control valve, upper boom 7. Control valve, lower boom Function of the manual pump is explained in chapter 11.
STARTING THE ENGINE / ELECTRIC MOTOR Read carefully this Operators Manual and also the Operators Manual for the engine before starting operation. Read and understand all safety instructions before starting operation. It is the operator’s responsibility to follow all operating and safety instructions. This access platform is destined for lifting of persons and additional load only.
(see 6.1.2)! Transmission of the LEGUAN 135 is hydrostatic. Each wheel is equipped with a hydraulic motor - the machine is four wheel drive. If the machine is equipped with rubber tracks there are two hydraulic motors in the track system.
Drive and boom movements are equipped with electric ramps with which the movements start and stop (progressivity of acceleration and deceleration). The ramps can be adjusted by Leguan service at the service page of the remote-control. The ramps are intended to make starting and stopping of the movements smoother.
8.4. Driving the lift on trailer There is a trailer available, specifically designed to transport the Leguan. The trailer must be fastened to the tow car when loading the machine on the trailer. Drive the machine on trailer with nose first...
As the rear of the lift extends over 1 m over the rear of the trailer, a reflector and red light must be mounted on the platform (picture on the left). The reflector is sufficient on daylight, but the red light is mandatory when it is dark.
8.5.1 Instructions for working environment In order to increase the lifespan of the track system, avoid driving on the following terrains or work sites: • Environments with crushed stone, iron bars, scrap metal or similar recycling material. Rubber tracks are not designed for this kind of environments.
OPERATION OF THE OUTRIGGERS Lifting of the booms without setting down the outriggers is never allowed! When setting down the outriggers the maximum allowed inclination of the chassis is 1.5°. With automatic leveling it is possible to level the machine within one degree. With the water level it is possible to level the machine within 0.5°.
Page 34
The booms must be in transport position before driving the outriggers up! ATTENTION! If there is the text “Leveling OK” on the display when the outriggers are not correctly deployed, the operation of this access platform is not allowed! Contact nearest Leguan service!
– in this case the telescopic boom is out more than one meter. LEGUAN 135 is also equipped with an overload control system which prevents boom movements in case the 230 kg safe working load is exceeded, or in case the telescopic boom comes out more than allowed when load on the platform is over 140 kg.
10.1. Boom deceleration Boom movement speed can be slowed with the deceleration switch (see 6.1.1). The switch is equipped with four positions: full speed and three decelerations. The active deceleration mode is shown with the green LED above the switch. The blinking frequency of the LED indicates the progressivity of deceleration.
EMERGENCY LOWERING If the power supply for some reason cuts off (e.g. no fuel or electricity cuts off, or connecting cable fails) the booms can be lowered as follows. 1. The lift is equipped with an electric emergency lowering system. There are emergency lowering buttons both on the platform and at ground level.
ENDING AN OPERATION When ending operation: 1. Lower the booms down to transport position. 2. Lift the outriggers completely up to transport position. 3. Stop the engine/motor with the remote-control start/stop switch. Turn off the remote control from its emergency stop switch. Lock the control unit in its place on the platform or take the unit with you.
Always tie the machine down diagonally from every corner. The tie-down to Leguan trailer is shown in the paragraph 8.4. ATTENTION! It is not allowed to tie down the machine so that the ropes go over the booms.
• Make sure that the checks according to the local regulations are done. ATTENTION! All spare parts – especially electric components and sensors – must be original Leguan parts. Always remember when handling the battery: • Battery contains corrosive sulfuric acid – handle the battery with care! When handling the battery wear protective clothing and eyewear.
Page 41
If you find a fault, operation of the access platform must be stopped immediately and the hose or the component must be replaced. Contact Leguan service.
SERVICE INSTRUCTIONS 15.1. Services and checks, maintenance schedule Regarding the service of the engine see also engine manufacturer’s Operators Manual = EM. CH = Check CL= Clean R = Replace A = Adjust F = First service at 50 h Operation daily monthly 100 h 200 h /...
23*8.50-12 grass profile 3.0 bar (79 PSI) 23*8.50-12 TR profile 3.0 bar (49 PSI) Leguan TeHo 2014 -trailer 2.9 bar (42 PSI) Leguan TeHo 2015 -trailer 4.4 bar (65 PSI) Do not exceed the maximum inflation pressure marked on the tyres! Wear pads on the telescopic boom must be checked every 5 years max.
Page 44
Greasing of the Slewing Ring The lift’s Slewing Ring must be greased monthly, according to the maintenance schedule. It is important to notice that the Slewing Ring has five (5) separate greasing points (Picture below) which all must be greased individually. The grease nipples on the outside of the Slewing Ring are connected to the gear and its bearings.
15.3. Handling of fuel and refueling Check fuel level and refuel if necessary (fuel tank, no. 1). Before refueling check which engine: petrol or diesel. In petrol engine use only fuel defined by the engine manufacturer in the engine Operators Manual. ATTENTION! Engine ignition switch (2) must be in position “1”...
When all four outriggers are on the ground, the squares are black. ATTENTION! If the set-up control system doesn’t work correctly, contact Leguan service. It is not allowed to use this access platform, and the failure/defect must be repaired before starting operation.
15.9. Adjustments in hydraulic system All settings of the hydraulic system have been made at the factory and normally there is no need to adjust them. Picture above shows the components next to the combustion engine: 1. Main hydraulic pressure sensor (the reading is shown on the remote-control display) 2.
Page 48
Picture above shows the components next to the platform: 1. Drive pressure adjustment point, 275 bar 2. Outrigger pressure adjustment point, 200 bar 3. Drive pressure check fitting 4. Outrigger pressure check fitting The picture on left shows the brake release block. Brake release can be adjusted by removing the bottom plate of the frame on the platform side.
Page 49
Picture on the left shows the components on the right side of the pedestal: 1. Boom pressure adjustment point, 200 bar 2. Boom pressure check fitting Picture on the left shows the boom slewing pressure adjustments: 1. Slewing counterclockwise, 120 bar 2.
If the values in the two channels differ more than 30 kg, boom movements are prevented. In this case contact Leguan service. If the sensor needs to be replaced the tightening torque for the screws is 150 Nm.
15.11. Electric sensors Transport position sensor S4 is located inside the transport support for the jib boom, see picture on the left. All the booms must be lowered down to transport supports in order so that the sensor recognizes that the booms are in transport position.
Page 52
The inclination sensor is located on the chassis next to the drive control valve. Readings of the inclination sensor are used in the automatic leveling of the machine. In addition, it prevents lifting of the booms if the inclination of the chassis exceeds the allowed value.
15.12. Check and adjustment of track tension Check and adjust track tension with the outriggers deployed and tracks lifted off the ground. First track tension check and eventual adjustment shall be made after first hour of operation. After that track tension shall be checked, and adjusted if needed, once a week. Check also tightness of the bolts and nuts of the sprockets.
REPAIR INSTRUCTIONS 16.1. Welding All load carrying steel parts are manufactured from S420MC EN10149-2 / S650MC EN10149-2 sheet and S355J2H EN10219 tube. Welding repairs are only allowed to be carried out by professional welders. When welding, use only methods and additives suited for above mentioned steel qualities. SFS EN-ISO 5817 quality level D of imperfections in welding is suitable for all weldings, except for load carrying parts.
TROUBLESHOOTING Following table shows possible failures and malfunctions of the access platform and the ways how to repair them. PROBLEM REASON CORRECTIVE ACTION Engine/electric motor does not Remot-control is not in Turn off remote-control and start when START lever is being connection with receiver.
Page 56
PROBLEM REASON CORRECTIVE ACTION Electric motor does not start Mains 230 V cable is not Connect 230 V mains, min. 16A when START lever is being connected to network. wall socket fuse. Make sure that moved. the socket is electrified. Emergency stop switch is Release emergency stop by pushed down.
Page 57
PROBLEM REASON CORRECTIVE ACTION Outrigger gives in. Make sure that the ground Put extra support plates under doesn’t give in. the outriggers or move to another place. Air in outrigger cylinder(s). Drive outriggers completely up and down a couple of times. Dirt in outrigger cylinder check Clean valve with compressed valve.
SERVICE HISTORY It is advisable to write down all service operations that are included in the periodical service. All services that have been made during the warranty period must be noted on the list below, otherwise the manufacturer’s warranty will void. The service operations mentioned in the maintenance schedule on chapter 15.1 shall be noted as follows: First Service (50 hours), 1 Month Service, 6 Month service, 1 Year / 200 Hour Service etc.