  • Page 1 Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 1 of 21 Option Ethernet Marine Master Clock WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se...
  • Page 2: Table Of Contents

    Firmware Download ............................18 Restart ................................18 Backup/Restore .............................. 18 Firmware Download / Wunser .......................... 19 General ..............................19 Alarm ................................. 20 WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se...
  • Page 3: General

    Units connected to the LAN, supporting NTP, can receive correct time from the Master Clock via the network module. Included with the Ethernet module is NyToP, Westerstrand NTP-client for Windows XP/7/8/10. To configure the different parameters such as IP-address, work mode etc. a normal web browser is used.
  • Page 4: Configuration

    SETUP Return to running mode by using . SPEC.-FUNCTIONS  SETUP SPEC.-FUNCTIONS  MON 14 OCT 2021 09:07:00 LTw WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se...
  • Page 5: Status Ip

    The Master Clock acts as a NTP-client receiving its time from an external NTP server. SYNC.SOURCE = GPS, RDS, DCF etc.; The Master Clock acts as a NTP server providing connected external clients with correct time. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se...
  • Page 6: Configuration Using A Web Browser

    A guest can read only. User name admin or guest. Password Enter a password. Default password is password. After login a menu is displayed: WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax.
  • Page 7: Status

    The main clock works as an NTP client and has received time from an external time server but has lost contact with the server and has therefore switched to using its built- in oscillator as a reference. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se...
  • Page 8 Authentication = MD5 authentication failed. See also section Alarm further down in this document Uptime Uptime for the Master Clock since last power failure Firmware Program version WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax.
  • Page 9: Network

    Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 9 of 21 Network Enter general network parameters WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se...
  • Page 10: Dhcp

    The selected tag is inserted into the data area of an Ethernet packet. VLAN prio Priority Values 0 (default, lowest priority) to 7 (highest priority) which can be used to prioritize network traffic for different types of data. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se...
  • Page 11: Utilities

    Westerstrand Ethernet products. Firmware updates are also handled by Wunser. Wunser uses UDP port 9999 when communicating with other Westerstrand products and UDP port 69 when downloading new firmware. These ports can be open, closed or prepared for encrypted communication.
  • Page 12: Ntp

    NTP settings General description Westerstrand NTP Servers has several features to achieve a reliable and accurate time service. The configuration of the different facilities is flexible, and the features can be selected or deselected depending on each customer’s individual needs.
  • Page 13: Ntp Mode

    Up to five different NTP servers can be entered. If the first one fails it will automatically go to the next one and so on. Interval Interval in seconds between NTP requests. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se...
  • Page 14: Ntp Advanced

    The server will still answer NTP requests from NTP clients. Broadcast address: 255.255.255.255 Multicast address: 224.0.1.1 Interval(s) NTP broadcast interval in seconds. This function is used if broadcast/multicast server is activated. See above. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA...
  • Page 15: Client

    Check box = On ; synchronise only if time server is operating on Stratum 1 level. Authentication If authentication is activated: Use MD5 authentication. Server ID/Key: Authentication data for the external NTP servers configured in the NTP server list. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se...
  • Page 16: Remote

    Document: DOK11086en01 WESTERSTRAND Author: PM Date: 2021-06-16 Page: 16 of 21 Remote Remote control Remote control of the Master Clock WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail:...
  • Page 17: General

    To switch off the password functionality enter password = nopassword Guest = Guest password. A guest can read only. The button [Save] is deactivated for guest users. Default password = password. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se...
  • Page 18: Lost Password

    Author: PM Date: 2021-06-16 Page: 18 of 21 Lost password If the password has been lost network card has to be cold started (FULL RESET). Contact Westerstrand for details. Firmware Download Function to enable firmware download. See also section Firmware Download.
  • Page 19: Firmware Download / Wunser

    The Master Clock has support for firmware upgrade via the network. The utility program Wunser is used for firmware upgrade. Wunser can be downloaded from Westerstrand.se If checkbox Firmware Download is clicked, then the application jumps to a boot-loader. If no firmware upgrade take place within 60 seconds, then the old application is restarted again with the current firmware.
  • Page 20: Alarm

    Short circuit on Remove the short circuit. CIRCUIT Alarm relay activated. impulse output If OK, clear the alarm. SNMP trap sent WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail: info@westerstrand.se...
  • Page 21 Alarm relay activated By some reason the Check the mains. DOWN power to the master clock has been switched off. WESTERSTRAND URFABRIK AB P.O. Box 133 Tel. +46 506 48000 Internet:: http://www.westerstrand.se SE-545 23 TÖREBODA Fax. +46 506 48051 E-mail:...