Download Print this page

STL EXTRA-N-LED Installation And Operation Manual

Advertisement

Quick Links

EXTRA-N-LED, MULTIEXTRA-N-LED, EXTRA-N-LED-Em
Installation and Operations Manual
phX 2 UKEX 1202X
B
II 3G Ex nR IIC T6 Gc
B
II 3D Ex tc IIIC T80°C Dc
IP66, insulation class I
The explosion proof light fitting meet the standards according to the UK SI 2016 No.1107 (incl.
amendments). They can be used in areas with danger of explosion as follows:
Area with danger of explosive
Marking
of exterior
ambient
Danger of explosion of
BE3N1
inflammable dust
Danger of explosion of
BE3N2
inflammable gas and vapors
In case of any erving on light fitting in premises with danger of exlosion, the national safety rules
and regulation for prevention of accidents are to be observed.
EXTRA-N-LED are LED dust proof and waterproof lighting fixtures designed for lighting premises
with danger of explosions.
EXTRA-N-LED-Em - non maintained emergency lifting.
MULTIEXTRA-N-LED - maintained emergency lifting.
Technical data:
Permited range of operating temperatures for 220-240V, 50/60Hz
EXTRA-N-LED-2500/5000-218/236
EXTRA-N-LED-5000/7500-218/258
EXTRA-N-LED-12550-258
EXTRA-N-LED-10000-236
EXTRA-N-LED-16700/20000-258
MULTIEXTRA-N-LED-2500-218
MULTIEXTRA-N-LED-5000/7500-236/258
MULTIEXTRA-N-LED-12550/258
EXTRA-N-LED-Em-500-218/236/258
EXTRA-N-LED-Em-1000-218/236/258
Nominal voltage and frequency:
for electronic ballast HELVAR:
for electronic ballast TRIDONIC:
for electronic ballast TCI:
for emergency unit AWEX:
for emergency unit TRIDONIC:
Pic.1
With fastening spring directly on the base
(included)
Operation and maintenance instructions:
The light fittings, which operate in areas of above mentioned premises, are under the requirements resulting from compulsory regulations of valid EN:
- The light fitting must not be open, if the terminal block is alive.
- Free outlets for supply cable must be sealed with plugs M20.
- Any change or replacements of components of the light fittings, which can influence the protection before the danger of explosion, are forbidden.
- The repair of the light fittings can be done only by person with relevant qualification, only with original spare parts and in compliance with the latest regulations.
1) Certificate of type phX 22 UKEX 1202X
Classification of area
Marking
Complusory regulation
ZONE 22
ČSN EN 60079-14
ČSN EN 60079-10-2
ZONE 2
ČSN EN 60079-14
ČSN EN 60079-10-1
-20°C to +60°C
-20°C to +55°C
-20°C to +45°C
-20°C to +40°C
-20°C to +40°C
0°C to +35°C
0°C to +40°C
0°C to +35°C
0°C to +50°C
0°C to +40°C
220-240V, 0/50-60Hz
220-240V, 0/50/60Hz
220-240V, 0/50-60Hz
220-240V, 50/60Hz
220-240V, 50/60Hz
Pic. 2
With steel wire hanger
(not included)
Lighting fixtue dimensions:
Type
A(mm)
B (mm)
EXTRA-N-LED-218
670
155
EXTRA-N-LED-236
1280
155
EXTRA-N-LED-258
1580
155
Maximum number of continuously connected luminaires for circuitbreaker type B10A
EXTRA-N-LED
MULTIEXTRA-N-LED
EXTRA-N-LED-2500-218
EXTRA-N-LED-5000-218
EXTRA-N-LED-5000-236
EXTRA-N-LED-10000-236
EXTRA-N-LED-7500-258
EXTRA-N-LED-12550-258
EXTRA-N-LED-16700-258
EXTRA-N-LED-20000-258
Pic. 3
With a cable suspension
(not included)
C (mm)
105
105
105
23
23
23
18
18
18
9
Page 1/3

Advertisement

loading
Need help?

Need help?

Do you have a question about the EXTRA-N-LED and is the answer not in the manual?

Questions and answers

Summary of Contents for STL EXTRA-N-LED

  • Page 1 Type A(mm) B (mm) C (mm) EXTRA-N-LED-218 EXTRA-N-LED are LED dust proof and waterproof lighting fixtures designed for lighting premises EXTRA-N-LED-236 1280 with danger of explosions. EXTRA-N-LED-Em - non maintained emergency lifting. EXTRA-N-LED-258 1580 MULTIEXTRA-N-LED - maintained emergency lifting.
  • Page 2 (see. Table sealing areas), which is a necessary condition for correct function of cable gland. Hole for power cable in the housing, which is not used cable gland (which is contained in the equipment luminaires), seal blanking plug. In the luminaire is not allowed to use respiratory protective plugs and cable glands breathing 7.Connect the suppling cable to the free part of incoming terminal strip as follows: EXTRA-N-LED EXTRA-N-LED-Em MULTIEXTRA-N-LED phase cond.
  • Page 3 In case of any interventions on fixture lighting in premises with danger of explosion, the national safety rules and regulation for prevention od accidents are to be observed. EXTRA-N-LED are LED based dust proof and waterproof lighting fixtures designed for lighting premises with danger of explosions.
  • Page 4 Declaration of Conformity _________________________________________________________________________________________ Product: LED Linear luminaire EXTRA-N-LED, EXTRA-N-LED-Em, MULTIEXTRA-N-LED Models: LED PCB – 3W-120W EXTRA-N-LED-1250-218 -20°C < ta <+45°C EXTRA-N-LED-2500-218 -20°C < ta <+60°C EXTRA-N-LED-5000-218 -20°C < ta <+55°C EXTRA-N-LED-2500/5000-236 -20°C < ta <+60°C EXTRA-N-LED-10000-236 -20°C < ta <+40°C EXTRA-N-LED-3750/7500-258 -20°C <...

This manual is also suitable for:

Multiextra-n-ledExtra-n-led-emExtra-n-led-218Extra-n-led-236Extra-n-led-258Extra-n-led-2500-218 ... Show all