Solo Pro
SELV RANGE
Installation and Wiring Instructions
FAN UNITS 12V 50Hz SELV (CLASS III)
CONTROLLERS 220-240V 50Hz MAINS SUPPLY (CLASS II)
WITH 12V 50Hz SELV OUTPUT
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.
PLEASE SAVE THESE INSTRUCTIONS.
Stock Ref. N°
Solo Pro SVP
409163
Solo Pro SVT
409164
Solo Pro SVHTP
409165
IPX7

Advertisement

loading

Summary of Contents for Vent-Axia Solo Pro SVP

  • Page 1 Solo Pro SELV RANGE Installation and Wiring Instructions Stock Ref. N° Solo Pro SVP 409163 Solo Pro SVT 409164 Solo Pro SVHTP 409165 FAN UNITS 12V 50Hz SELV (CLASS III) CONTROLLERS 220-240V 50Hz MAINS SUPPLY (CLASS II) WITH 12V 50Hz SELV OUTPUT IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.
  • Page 3 C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. The fan should only be used in conjunction with fixed wiring.
  • Page 4 A window fitting kit is available. Stock reference 11461685. A. INSTALLATION SITING THE CONTROLLER The controller must not be installed in a shower cubicle or enclosure. It must be sited away from direct sources of water spray and out of reach (1.5m) of a person using a fixed bath or shower.
  • Page 5 B. WIRING. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. IMPORTANT: The controller is only suitable for connection to a 220-240V 50Hz AC single phase mains electrical supply. It is double insulated (CLASS II) and therefore must not be earthed.
  • Page 6: Servicing And Maintenance

    HUMIDITY SET-POINT ADJUSTMENT (FIG. 4 AND 5) BEFORE ADJUSTING THE CONTROLLER, SWITCH OFF THE MAINS SUPPLY. HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. Remove the fan and PCB covers and impeller. The controller is factory set to switch on at about 70% RH. The humidity set point can be adjusted from 40- 95%RH by altering the adjuster on the control PCB.
  • Page 7 Fig.1 (Solo Pro SVP) SELV Supply 1 Phase Supply (12V 50Hz) (220-240V 50Hz). FUSE 3A(UK) Switched Fused Spur Controller Fig.2 (Solo Pro SVT) SELV Supply (12V 50Hz) Controller Fig.3 (Solo Pro SVHTP) SELV Supply (12V 50Hz) Controller...
  • Page 9 Fig.4. continued. Remove the PCB cover 4) Push clips together to release the impeller 5) Remove two screws as shown Fig.5. Wiring and settings Supply cable via side or rear Supply cable connections Adjust Timer overrun or Humidistat set point (model dependant) as shown. (SVHTP)
  • Page 10 Fig. 6. Recessed Mounting 1. Insert the two mounting brackets at the top and bottom of the fan housing 2. Place the fan housing in the wall recess. Mark the screw centres. Drill, plug and screw into position.
  • Page 12 Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:- ...