Page 5
Air pump is pulsing and air is rushing out the exhaust on the pump. The diaphragm in the pump has failed. Disassemble pump and replace diaphragm with BG rebuild kit Part No. PF91020D. Pump runs but doesn’t pull vacuum.
Page 6
LIMITED WARRANTY This product is warranted by BG Products, Inc., to be free of defects in workmanship and materials for a period of one (1) year from the date of purchase by original purchaser. If the product fails within this period, it will be repaired or replaced at seller’s option, provided (1) the product is submitted with proof of purchase date and (2) transportation...