SAFETY Please ensure that you follow these guidelines when handling batteries: • Always wear personal protective equipment. • Use lift straps or handles to move or carry batteries. • Fuse all circuits that are connected to the battery. • Always check for correct polarity and avoid short circuiting the battery. •...
Page 5
- Up to 10 batteries can be connected in parallel. - Ensure equal cable lengths and consistent sizes are used. - Each battery must be within 0.05V before installing. Series Connections: - Always use batteries of the same make and model - Make sure the battery cables are connected to the correct terminal points.
Page 6
- Leaving a battery at 0% state of charge for an extended period will cause permanent damage. BMS / OPERATION BMS – Battery Management System is designed to ensure your lithium battery operates within its specified parameters. The BMS is integrated into each of our lithium batteries.