III. SPECIFICATIONS AND UNIT IDENTIFICATION PACKAGE AIR CONDITIONER MODEL NUMBER BREAKDOWN 1 - 12 VDC Control Voltage 2 - 24 VAC Control Voltage Model Series 8 - No Start Kit 9 - Start Kit Included Revision Letter 6 - Panasonic Compressor(s) 7 - Sanyo Compressor(s) 8 - Tecumseh Compressor(s) SPECIFICATIONS...
Page 6
VI. ELECTRICAL COMPONENTS IDENTIFICATION PART # DESCRIPTION Control Board Coil Sensor Fan Relay Heater Relay Start Capacitor Heat Element Limit Switch Plug Assembly Transformer Run Capacitor Fan Capacitor...
VII. QUICK TROUBLESHOOTING TIPS VIII. COMPONENT CHECKOUT THINK SAFETY other wires. All switches, fuses, circuit breakers, disconnects, etc. should be in this line. Power Supply - from Commercial Utility The wire with the white insulation is the Wire Size neutral. There should be 115 volts (domestic USA) between the neutral and the The power supply to the air conditioner must come through a hot (black) wire, but there should be 0 volts...
Page 8
Voltage High Amperes (Current) The voltage (electrical pressure) at the unit should be 115 The switch contains a heater which volts (domestic USA) and all electrical components will increases in temperature as the current perform best at the correct voltage. However, the voltage will increases.
Page 9
The brown wires from the motor connect to Capacitor Check the fan capacitor. There are several capacitor test devices available. The ohm To check the motor winding resistance, carefully meter is one of them. The ohm meter cannot verify a check the resistance between each of the wires and capacitors MFD (microfarrad) value.
Page 10
Good Capacitor Shorted Capacitor If the capacitor is good, the indicator will move from infinity If the capacitor is shorted, the indicator will move toward and (the left side), up towards zero ohms and slowly return back sometimes hit zero ohms, and will stay there. This indicates to infinity.
capacitor when the motor reaches approximately 75% A high voltage coil internally between terminals #5 running speed. and #2 to actuate the contacts. The coil is too weak on line voltage to actuate the contacts, but it is Notice the resistor which is soldered to the terminals of the connected in series with the start winding and it gets start capacitor.
Page 12
Fan Runs - No Compressor Turn Thermostat To Cool And Turn Temperature Down So That The Thermostat Should Be Calling For Cooling...
Page 13
Compressor Runs - No Fan Thermostat In Cooling Mode And Turned Down So That It Will Be Calling For Cooling...
Page 14
Fan Runs - No Heat Thermostat In Heating Mode and Turned Up So That It Will Be Calling For Heat...
Page 15
Heat Runs - No Fan Thermostat In Heating Mode And Turned Up So That It Will Be Calling For Heat...