5w smd led rechargeable emergency floodlight

Advertisement

b) Eye contact: Flush eye immediately with cool, clean running water for at least 15 minutes, seek immediate medical attention.
2. INTRODUCTION
LED Light automatically comes on when power source is switched off. Maximum run time of 6 hours to provide light for a prolonged
period during power failure. 5W SMD LED Dual mode setting producing up to 500 Lumens which can illuminate a large room/area.
Floodlight has a built-in charging cable, battery and stand. Featuring charging level indicator. 3.7V 4000mAh Li-ion battery.
3. SPECIFICATION
Model No:.............................................................LED1200E
Battery: .................................................3.7V 4000mAh Li-ion
Charging Time: ................................................................20hr
LED Qty ........................................................................... 120
Lumen Output .............................................................. 500lm
Operating Time: ............................................6hr/low 3hr/high
Supply: ...........................................................................230V
4. OPERATION
4.1.
CHARGING THE UNIT
The unit will charge when plugged into mains supply regardless of function switch position. To achieve fastest charge put function switch to the
4.1.1.
'OFF' position.
4.1.2.
It is important that the light is recharged for approximately 18-24hours before it is used for the first time.
4.1.3.
Charge at least every three months to maintain optimal battery life.
4.1.4.
Open the power cable compartment at the back of the light.(fig.2) Uncoil the power cable and plug it into the mains power supply. The red
LED will light to indicate the presence of mains power.
4.1.5.
The battery pack will take approximately 20 hours to charge initially. Subsequent charging times will depend on the state of discharge of the
battery pack.
4.1.6.
When charging is complete indicated by Green LED will illuminate(fig.1) then unplug the mains power cable and stow it back in the
compartment.(fig.2)
4.2.
USING THE LIGHT
The function switch has three positions:(fig.1)- 1 Low - OFF - High.
4.2.1.
Select the required brightness using combination using the function switch.
4.2.2.
4.2.3.
The lamp is fitted with a carrying handle (fig.3) and a support stand (fig.4)
4.2.4.
The light will function as an emergency light if the function switch is placed in either the Low or High position whilst connected to the mains.
In case of a mains electricity failure, the selected Low or High will light. Restoration of mains power will switch the light off again.(There is
also a test function to be sure that the light is operational).
4.2.5.
After a full charge the light will run for approximately 3hr on High and 6hrs on Low.
4.2.6.
This unit is Splash Resistant and NOT Waterproof so do not immerse the Floor Light in water.
DO NOT store the Floor light in humid, damp areas nor allow it to be exposed to direct sunlight for extended periods as this may damage
8
the unit.
4.3.
MAINTENANCE
4.3.1. Clean the unit with a damp cloth and a mild soapy solution. DO NOT use solvents or abrasive cleaners.