IMPORTANT! For safety reasons it is essential that your stove is correctly installed and operated. Henley Stoves cannot accept responsibility for any fault or consequential problems arising through incorrect installation or operation. THIS PRODUCT MUST BE INSTALLED BY A HETAS / METAC QUALIFIED INSTALLER...
This manual contains instructions on how to install and maintain your Henley Stove. For both your comfort & safety please take the time to read instructions carefully. HENLEY STOVES 5 YEAR WARRANTY You need to register your warranty online or via the post in order to activate the warranty for your stove.
Technical Information Dimensions: Athens 400, Athens 500, Athens 700 & Athens 900 Model Size A Size B Size C Size D Size E Size F Size G Athens 400 626MM 468MM 550MM 375MM 95MM 395MM 118MM Athens 500 630MM 577MM...
Stove Commissioning Checklist Please complete the form below as it will be of great assistance in the highly unlikely event that there is a problem with the stove or a warranty claim needs to be made. Please contact the person who installed the stove or the dealer where it was purchased from if there is a problem.
Installation Instructions Installation Fire Cement Some types of fire cement are caustic and Before installation and/or use of this appliance please read these instructions carefully to ensure should not be allowed to come into contact that all requirements are fully understood. The with the skin.
Hearth Hearths should be constructed from suitably ro- (fig.1) bust materials & to appropriate dimensions. fig.1 Constructional Hearth Dimensions fig.2 Non Combustible Hearth for Solid Fuel Appliances & Open Fires surrounding Solid Fuel Appliance A way of making provision would be to adopt the guidelines outlined below &...
Ventilation Ventilation This appliance requires a constant supply of air The following must be checked: to maintain proper combustion and effective flue • The construction of the masonry chimneys, performance. flue block chimneys & connecting flue pipe system must meet requirements of the Building An inadequate air supply can result in poor Regulations.
Chimney Suitable access must be provided to enable the collection and removal of debris. The flue must be swept and inspected when the appliance is installed. The flue draught must be checked with all windows and doors closed and any extraction fans in this, or adjoining rooms, running at WARNING maximum speed (see next section for additional...
Height Over Adjacent Building The Outlet of a chimney or flue in relation to an adjacent building should be as seen above Height Over Roof Outlet of a chimney or a flue to be not less that 1m above the highest point of contact of chimney and roof. Where the roof has a pitch of more than 10º...
Flue Options Each installation is unique to the property so it is not possible to give details to suit every setting. The installation must comply with Building Regulations and be made using best practice construction methods. WARNING Many fireplace openings have a supporting lintel. If Not using External Air Supply Do not remove without supporting the remaining Do not remove cover from back...
Page 11
When Installing a Henley Insert Stove there To further prevent excessive heat build up, are a number of considerations to be taken into Henley Stoves recommend that a hole be drilled account before commencing installation. into the wall at the side of the chimney breast to let trapped heat escape.
If stone / granite / marble or any other natural material is used to construct the fire surround, Henley stoves recommended that a high or any part of it, considerations should be temperature plaster which does not contain any made for expansion and movement of the gypsum is used.
Athens should be a minimum of 1,100mm to Front for Athens 400, and 1,300mm to the It is an offence to emit smoke from a chimney of Front for Athens 500, 700 and 900. Materials...
Refueling the Stove Lighting the Stove When burning wood, the fire will die down as the We recommend that you have two or three small fuel is consumed. When the flames disappear fires before you operate your stove to its maxi- and the remainder is breaking down into glowing mum heat output.
Shutting Down Stove The stove will normally shut down by itself as the fuel is consumed. In order to shut down the stove for other reasons, close the primary air controls (if open), When refueling the appliance it was then close the secondary air control. necessary to leave the door ajar for a period of 1 - 2 minutes in order to sustain flames on If the controls are left in this position, the fire will...
This should be done by and competent person Maintenance: Removing Fire Rope such as a NACS chimney engineer who will provide a Certificate of Chimney Sweeping. Periodically visually check over the door rope seal for any damage, cuts or tears and detached Sweep the whole flue way, including the outlet at sections.
Page 17
Replace the four retaining clips and fixing Replacing Baffle Plate Maintenance: • screws. Do not over tighten the fixings as Prior to installation, internal components of the damage may occur to the glass. stove including the baffle are removed to gain Refit the door assembly back onto the stove, •...
Air Controls Henley Stoves appliances have air systems providing cleaner burning, and greater efficiency and control. Please see diagram to view where the various air controls are located on your Henley Stove 1) Primary Air Sliding this lever out opens the primary air and allows air into the stove.
Call the Fire Service - Dial 999 or 112 Aerosol tins of paint are available for complete • Immediately close all of the air inlets to refurbishing from Henley Stoves. the appliance to reduce the air supply to the fire. Repainting Instructions: •...
Spare Parts Over time you may require replacement parts for your Henley Stove. Replacement parts are available through your local stockist. Please use the below diagram to establish the part you require for your stove. Please ensure you quote model name and also serial number of stove when ordering spare parts. ONLY USE GENUINE HENLEY APPROVED REPLACEMENT PARTS FOR YOUR STOVE.