Adjustment Procedures

CLOCK
1. Set SPEED, REGEN, WITDH, and DELAY TIME controls fully counter-clockwise (CCW).
2. Connect an oscilloscope to test point CP1.
3. Adjust VR101 CLOCK TRIM for a frequency of 40kHz.
4. Set DELAY TIME control fully clockwise (CW) and check CP1 frequency. Should be in the
range of 500kHz to 600kHz.
5. Set WIDTH control fully CW and check CP1 frequency sweep. The range should be from
40kHz to 500kHz-600kHz.
BIAS
1. Set REGEN and WIDTH controls fully CCW.
2. Connect a +5dBm to +10dBm (2.5 volt) 440Hz sine wave to the INPUT.
3. View the waveform on test point CP12. Adjust VR102 BIAS to achieve a symmetrically-
clipped waveform.
REGEN
1. Set SPEED, REGEN, and WIDTH controls fully CW.
2. Connect an oscilloscope to the OUTPUT with no INPUT signal
3. Adjust VR103 REGENERATION TRIM until oscillation is seen. Back down VR103
REGENERATION TRIM about 10 degrees to squelch the oscillation.
FL9 Flanger Service Guide
40kHz 5-volt peak
550kHz 5-volt peak
440Hz 1-volt peak