fig.9
4.15.
SHADE CONTROL (fig.10)
4.15.1.
Select the shade DIN 9 to 13 based upon the welding process you will use by consulting the"Shade
Guide Table" based on EN 379. The variable shade control knob is for external adjustment. Grind
mode DIN 4 prevents filter lens from auto-darkening for grinding use.
4.16.
SENSITIVITY CONTROL (fig.11)
4.16.1.
The sensitivity can be set from MIN to MAX by using the infinitely dial knob. The MIN setting suits excess ambient light or with
another welding machine close by. The MAX setting suits low amperage welding and welding in areas with low light conditions,
especially low amperage argon arc welding. Selections between MIN and MAX are suitable for most of indoor and outdoor welding
operations.
4.17.
DELAY CONTROL (fig.11)
4.17.1.
When welding ceases, the viewing window automatically changes from dark back to light but with a pre-set delay to compensate.
The delay time can be set from SLOW(0.8s) to MIDDLE(0.5s) to FAST(0.2s), by the DELAY switch.The minimum delay suits spot
or short welds. The maximum delay suits heavy current welding and reduces eye fatigue from the arc. Selections between SLOW-
MIDDLE are suitable for most of indoor and outdoor welding operations.
4.18.
SHADE GUIDE TABLE.

5. MAINTENANCE

5.1.
PAPR CLEANING:
5.1.1.
Detach the battery pack, hose assembly and the blower. Inspect all parts for damage. Replace all damaged parts prior to storage
or next use.
5.2.
BLOWER
5.2.1.
Clean the outer surfaces of PAPR assembly and battery pack with a soft cloth dampened in a solution of water and mild, pH
neutral detergent.
DO NOT immerse the blower or battery pack in water.
8
DO NOT use solvents or abrasive cleaners.
8
DO NOT attempt to clean the interior of the blower with compressed air or vacuum.
8
Ensure the electrical contacts of the blower and battery pack are dry.
9
5.3.

HOSE ASSEMBLY

5.3.1.
Clean the connection joints on the hose assembly with water and a mild detergent solution.
NOTE: The hose assembly can be immersed in water for cleaning.
5.3.2.
Air dry or dry by connecting to the blower unit and blow dry the hose.
NOTE: The inside of the hose must be completely dried prior to use or storage.
5.4.
HEPA FILTER
5.4.1.
Remove the filter cover and inspect the filter,replace if excessively dirty.
5.5.
FRONT COVER LENS REPLACEMENT
5.5.1.
Replace the front cover lens if it is damaged (cracked, scratched, pitted or dirty). Remove the old front cover lens by pressing two
lock switches at the bottom of the retaining frame and pull the frame and ADF out. Take the old front cover lens out, and remove
any protective film before installing the new one. Cover lens by pressing two lock switches at the bottom of the retaining frame and
pull the frame and ADF out.