Mitsubishi Electric PLA-ZP35EA Service Manual page 33

Split-type, heat pump air conditioners
Hide thumbs Also See for PLA-ZP35EA:
Table of Contents

Advertisement

10-2. ELECTRICAL CIRCUIT (Controller board and wiring diagram (Panel))
10-2-1 DIP SW
SW2
[ LEGEND ]
SYMBOL
NAME
U.B
ELEVATION PANEL CONTROLLER BOARD
LED ORANGE
LED2
(INTAKE GRILLE CONDITION (See table *1))
LED GREEN
LED4
(COMMUNICATION WITH INDOOR UNIT)
U.K 1
ELEVATION MACHINE
M
MOTOR (ELEVATION)
LS21 DETECTION SWITCH (STRING TENSION)
I.B
INDOOR UNIT CONTROLLER BOARD
W.B
PCB OF SIGNAL RECEIVER
BZ
BUZZER
RU
RECEIVING UNIT
LED GREEN
LED1
(OPERATION INDICATION)
LED ORANGE
LED2
(PREPARATION FOR HEATING)
EMERGENCY HEATING
INTAKE GRILLE/DOWN
SW1
(LONG PRESS FOR OVER 2SEC.)
(SHORT PRESS)
EMERGENCY COOLING
INTAKE GRILLE/UP
SW2
(LONG PRESS FOR OVER 2SEC.)
(SHORT PRESS)
LS1
DETECTION SWITCH (INTAKE GRILLE STORAGE)
WIRED REMOTE CONTROLLER
R.B
<*2>SW2 on U.B
LOWERING
LOWERING
SET UP
DISTANCE
DISTANCE
ON
ON
1.2m
OFF
2.8m
OFF
1 2 3 4 5 6
1.6m
ON
ON
(Initial
OFF
3.2m
OFF
setting)
1 2 3 4 5 6
ON
ON
2.0m
OFF
3.6m
OFF
1 2 3 4 5 6
ON
ON
2.4m
OFF
OFF
4.0m
1 2 3 4 5 6
Note: The actual lowering distance might be
different from the distance in the table 2
since it can also be set using the wired
remote controller.
10-2-2. Check point of trouble
<LED 2 Orange display>
Turn OFF
: No power supply
Blink
: Storage detection switch ON (short)
One blink
: Storage detection switch OFF (open)
Two blinks
: Tension detection switch OFF (open)
<controller board>
Check item
Up/down controller
P.C. board supply
voltage
Up/down machine
supply voltage
<Up/down machine>
Check item
Storage detection
switch
Tension detection
switch
Motor
Entwining strings
OCH625
[EMERGENCY OPERATION]
1. If the wireless remote controller for ELEVATION PANEL is faulty or lost, operation
will be possible using the emergency up/down switch at the wireless signal receiver
or wired remote controller.
▪ For the operation using the emergency up/down switch at the wireless signal
 receiver, refer to SW1 and SW2 on the left [LEGEND].
2. When machine for ELEVATION PANEL breaks down, a intake grille is fixed for
  a while, and the operation of the unit can be done.
▪ Refer to installation manual with the grille for the details such as an installation
 method.
LS21
LS1
U.B
CN2G
(BK)
2 1
2
(GNYE)
CN2E
CN2F
(RD)
(BK)
Grille side
SET UP
I.B
Indoor unit
side
1 2 3 4 5 6
1 2 3 4 5 6
[ Note ]
1. Symbols used in wiring diagram above are,
1 2 3 4 5 6
2. The black square ( ) indicates a switch position.
1 2 3 4 5 6
Check point
Normal
CN4A
11–14 V AC
(between 1–2)
CN3B
(between 1–2)
10–13.5 V DC
CN3C
(between 1–2)
Check point
Normal
CN2E
open or short
CN2F, CN2G
open or short
CN3B, CN3C
5–20 "
Retention:
Pull string
about 2 kgf
LED4
LED2
<*1> LED2 on U.B
LED2
U.K 1
U.K 1
LIGHTING
LS21
1-TIME BLINKING
M
M
2-TIME BLINKING
2 1
3
2
1
3
2
1
W.B
CN4G
(BK)
CN3C
CN3B
(WH)
(WH)
4
1
1
Lowering distance setting
LED4
<See table *2>
ON
SW2
OFF
LED2
1 2 3 4 5 6
4
CN4G
(BU)
<LED 4 Green display>
Blink
: Connecting
Remarks
Check when instructing up/down with LED
blinking once.
Check contents
Check if it is short when pressing push switch.
Check if it is short when string b is tensioned.
Check if it is not open or short.
Check if string is drawn out by pulling with 4 kgf.
33
33
INTAKE GRILLE CONDITION
INTAKE GRILLE HOUSED AND STRING TENSIONED
INTAKE GRILLE NOT HOUSED AND STRING TENSIONED
STRING NOT TENSIONED
RU
SW2
SW1
BZ
LED1
LED2
CNB
(WH)
1
9
9
R.B
TB5
TB6
2
2
2
CN90
(WH)
1
1
: Connector,
: Terminal (block).