Norden NVS-IP30008PM User Manual

Wall mounted ip based paging station

Advertisement

Quick Links

NVS-IP30008PM
Wall Mounted IP Based Paging Station
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Norden NVS-IP30008PM

  • Page 1 NVS-IP30008PM Wall Mounted IP Based Paging Station User Manual...
  • Page 2: Device Description

    1.1 Device Description NVS-IP30008PM is a network high-fidelity wall-mounted intelligent paging station is a on TCP/IP transmission protocol, which can be connected to anywhere in the network . With the characteristics of the high stability of the traditional paging station, the operation is stable and reliable, and the failure rate is low.
  • Page 3: Front Panel

     Can play network host program library songs.  With the audio logging function, the paging content can be recorded in real time, and can be played later.  User password and rights management option. 2. Appearance 2.1 Front panel 1.
  • Page 4: Rear Panel

    7. Built-in microphone: When the switch key is pressed (that is, the handheld microphone/handset hangs), the built-in microphone will be automatically opened, you can aim at the microphone to speak to each other, the built-in speakers will output the other voice. 8.
  • Page 5: Network Connection Diagram

    3. Connection 3.1 Network Connection Diagram The paging microphone, Server & other devises must be in the same network 3.2 Device connection Diagram The line in connection can be used to connect local audio inputs such as CD player FM tuner etc. The audio from these local audio sources can be transmitted to network using this paging microphone.
  • Page 6: Operation

    4. Operation Plug the device into power source after making necessary connections, then turn on the power switch on the rear panel 4.1 Power-on Interface & main menu After successful boot, the system will initialize the settings and will display "Starting, please wait ...", during which the system will load the information of the last run of this paging station, and so on, after around 25 seconds it display the login interface as shown in the below image In this window, the user can enter the username &...
  • Page 7: Zone Status Display

    All controls can be one in this menu. All the output devices connected to the system will be displayed here. To control a device, it is mandatory to select that device / group. Then it is possible to make announcement, select audio source, Control volume etc. 4.2 Zone Status Display Displays the current working status of each in this menu, such as the zone name, current work task/status, volume level etc.
  • Page 8: Zone Paging

    4.3 Zone Paging To call paging a zone:  In the first step, touch the "Zone Call" icon on the upper right side of the main interface, then touch and select the zone to be called (a selected zone will be surrounded by red box), and then touch the "Call"...
  • Page 9 The programs folders in the server will display under “Directory” area. Once a directory is selected, the program files will be displayed under “Music” area. On the bottom left area, there is a toggle button. It will toggle between “Listen” & “Broadcast”. This button should be in listen mode to pre-listen a music or message.
  • Page 10: Other Buttons

    Other Buttons Inverse the current selection Play Chime tone These buttons can be used for navigating to next & previous page Logout from main menu Go to system settings System setting System settings can be opened by pressing “SYS Setting “Button.
  • Page 11: Group Setting

    The sub menu items are explained below:  Group settings : grouping settings for zones.  Network settings : Set IP address and subnet mask for this paging station.  Time setting : Set the system time and date.  Backlight time : For this paging station to set the screen backlight light time.
  • Page 12 Assign zones to the selected group on demand on the interface. The box on the right shows all the zones, selects the zones you want to add to the current group, touches the arrows that point to the left border, and moves to the left box to indicate that the group has been added.
  • Page 13: Network Setting

    Group Add Zone Settings interface When the group settings are complete, touch the "back" button to exit the Setup interface. 4.8.2 Network Setting Enter the "System Settings" interface, touch the "Network Settings" icon, into the network settings of this paging station interface. The IP address, subnet mask, gateway, and server IP of this paging station can be set.
  • Page 14: Backlight Time

    4.8.4 Backlight Time Enter the "System Settings" interface, touch the "Backlight time" icon to enter the screen backlight light time Setup interface.  Touch the circle in front of the light time value or steady state, the circle inside the white display "...
  • Page 15: Parameter Setting

    Parameter setting Enter the "System Settings" interface, touch the "Parameter Settings" button to enter the parameter settings interface, the interface as shown in the following image Parameter Settings interface  4.9.1 Local Output Settings Whether the line output (output) on the back panel of the machine is exported when the microphone or line input is set.
  • Page 16 Screen Calibration Important NOTE: Screen calibration operation should be carefully aligned to the cross cursor and then click, do not randomly touch the screen, otherwise it is possible to make correction errors, resulting in the failure to operate. If the touch screen cannot be used without accurate calibration screen operation, then the screen can be reset by the "CALL ALL"...
  • Page 17: Timeout Processing

    In the figure above, use the number button on the right to enter the password. "Original password" set to blank, if the user set their own password, the next time you change the password need to enter an existing password to update the password. When the settings are complete, touch the “OK” button to take effect. In the “System Setting”...
  • Page 18  Call Forwarding: Call the other party in the set time no answer, then automatically transferred to the next intelligent paging station.  Timeout rejection: If the call transfer is not set to set the time to automatically refuse to speak request.
  • Page 19 Different users can set the visible zones according to their actual requirements, administrators can assign the user modify permissions, if not assigned permissions, the user enter the system settings can only set the parameters such as backlight time, microphone settings, log, etc., and cannot set system parameters such as grouping settings, zone management, network settings, such as parameters.
  • Page 20: Safety Precautions

    Safety Precautions  Please do NOT connect this device to the power source before the system is correctly wired.  It is important to ensure that input voltage to the device is the same as required voltage of the device, otherwise the device may be damaged. ...

Table of Contents