MT84G 2D Mini Scan Engine, Integration Guide, V0.4 TABLE OF CONTENTS N ..................1 1-1. Block Diagram ................. 1 e ................2 t ..............2 s ............4 g ................4 p ................4 e ................4 g ............... 5 s ...........
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 The MT84G 2D Mini Barcode Scan Engine is the smallest 2D barcode scan engines in the industry; it features middle range reading, high performance barcode scanning with optimal performance and easy integration. MT84G is ideal for integration into data terminals and small mobile devices with limited space.
Page 5
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 Pin# UART Description Schematic Example Decode LED Output Decode LED output LED1 GREEN 330R Decode LED 2N3904 3.3V supply voltage +3V3 input UART RXD Input UART TTL data input RS232 IC UART TXD...
This chapter describes the timing associated with the various operating modes of the MT84G including Power Up, Sleep Mode, and Decode Timing. When power is initially applied, the MT84G is activated and begins the process of initialization. Once initialization (duration≧1000mS) is completed, the MT84G emits power-up beeps, enters Standby Mode and is ready for barcode scanning.
Buzzer PWM signal) is approximately 100mS. In Sleep Mode, the MT84G can be waken up by the Trigger signal which MUST be kept low for at least 15mS, to prompt the scan engine into Standby Mode.
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 This chapter provides technical specifications of the MT84G scan engine. Operating method, scanning range and scan angle are also presented. Optic & Performance White LED Light Source Red LED Sensor 640 x 480 pixels...
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 Idle Current < 1.5 mA (Sleep Mode) Connectivity UART (TTL-level RS232) Interface USB HID (HID Keyboard) USB VCP (Virtual COM) User Environment Operating Temperature -20°C ~ 60°C Storage Temperature -40°C ~ 70°C...
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 MicroPDF417 Data Matrix Aztec MaxiCode Han Xin Code16K Regulatory Functional after 4KV contact, 8KV air discharge (it requires housing that is designed for ESD protection and stray from electric fields.) FCC – Part15 Subpart B (Class B) CE –...
(2) Configurable by serial commands. (3) Supports both software & hardware trigger Interface Configuration Barcode: UART Scanning above barcode will set your MT84G to UART interface. Characteristics: (1) Configurable by scanning configuration barcodes. (2) Supports hardware trigger only Interface Configuration Barcode:...
Scanning above barcode will set your MT84G to USB VCP interface. 1. At power-up, the MT84G sends the Power-Up (PWM) signals over Buzzer pin as an indication that the MT84G enters Standby Mode and is ready for operation. 2. Once the MT84G triggered by either hardware or software method, it will emit white illumination with a narrow, horizontal slab of red light which helps user target the barcode.
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 (unit = mm) Front View Back View Bottom View Top View Side View ___________________________________________________________________________________...
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 Be aware of the tolerance for the pitch, roll and skew angle of barcode you are trying to scan. Pitch Angle: ± 80° Skew Angle: ± 80° Roll Angle: ± 360° ___________________________________________________________________________________...
1. ALWAYS use grounding wrist straps and a grounded work area when unpacking and handling the MT84G. 2. Mount the MT84G in a housing that is designed for ESD protection and stray electric fields. ___________________________________________________________________________________...
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 Mounting the MT84G First of all, the MT84G should be fixed with machine screws on the host PCBA. To secure MT84G the maximum thread depth is 2.0 mm and operator must use safe ESD practices when handling and mounting the MT84G.
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 Following are descriptions of three popular window materials: 1. Poly-methyl Methacrylic (PMMA) 2. Allyl Diglycol Carbonate (ADC) 3. Chemically tempered float glass Cell Cast Acrylic (ASTM: PMMA) Cell cast Acrylic, or Poly-methyl Methacrylic is fabricated by casting acrylic between two precision sheet of glass.
Page 19
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 The recommended thickness of window is 0.8~1.0 mm. The recommended distance between window and scan engine is < 0.5 mm. Window Specifications for MT84G Integration Minimum Window Size Distance Horizontal (h) Vertical (v) Thickness (t) <...
Page 20
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 The window size must increase as it is moved away from MT84G and should be sized to accommodate the field of view and illumination envelopes shown below: (Top View) (Side View) ___________________________________________________________________________________...
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 In the aspect of window, the performance of MT84G will be reduced due to any kind of scratch. Thus, reducing the damage of window, there are few things have to be noticed.
(P/N: 5300-1315X00) Micro USB Cable (P/N: 7005-9892A50) Due to the advantage of its small size, MB100 Multi I/O board is also suitable for being installed inside the host system, as an interface board connecting MT84G to the host device. ___________________________________________________________________________________...
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 The Sleep Mode is disabled by default. To enable Sleep Mode, please scan Enable Sleep Mode configuration barcode below. When enabled, MT84G automatically sleeps (with idle current < 1mA) after a period of inactivity, or Sleep Timeout (default = 30 sec).
MT84G 2D Mini Scan Engine, Integration Guide, V0.4 You can set up your MT84G using the following method: 1. Configuration Barcode: Scan configuration barcodes from the MT84G Users Manual. 2. Serial Command: Send command based on MT84G Serial Commands Manual.