PLD331 Microstepping stepper motor driver I N S T R U CT I O N M A N U A L 01. General information 02. Delivery set 03. Technical features 04. Driver functional capabilities 05. Control Signal Connections to the driver 06.
1:1, 1:2, 1:8, 1:16 Stepdivision (microstep) STEP Max signal frequency 50 kHz PLD331 is a microstepping stepper motor driver based on TB6560 microchip (TOSHIBA). The device has inbuilt coil short-circuit Max shaft rotation frequency 30 cycles per second protection, polarity reversal power protection, protection against...
20mА, action time is 0,1 ms. Logic unit (input supply) – stepper motor driver is switched off and coils are off the current, zero – stepper motor driver is on and stepper motor coils are supplied. Ø3,5 Fig. 1. Stermotor driver PLD331 dimensions 8 (800) 555 63 74 www.purelogic.ru Edition from 23.11.2017...
05. Control Signal Connections to the driver PLD331. Microstepping stepper motor driver Fig. 2. General scheme of CNC control 8 (800) 555 63 74 www.purelogic.ru Edition from 23.11.2017...
PLD331. Microstepping stepper motor driver Stepper motor connection to the driver PLD331 driver is optimal for bipolar and unipolar stepper motors Purelogic R&D series PL42/PL57. Stepper motor connection to the driver is performed as it is shown in fig. 5 (clips PH1.1[+A], PH1.2[-A] and PH2.1[+B], PH2.2[-B]).
07. Stepper motor connection to the driver PLD331. Microstepping stepper motor driver - Jumper is set - Jumper is removed Fig. 5. Stepper motor driver connection scheme 8 (800) 555 63 74 www.purelogic.ru Edition from 23.11.2017...
Page 7
3.2. If the defect is proved, warranty repair is carried out. microstep mode. This mode allows to reduce stepper motor resonances at low revs. It is recommended to use PLD331 driver in step division 1:8 and higher. 8 (800) 555 63 74 www.purelogic.ru...
Page 8
10. Terms of Warranty PLD331. Microstepping stepper motor driver 4. We do not assume any responsibility for glass, electric lamps, starters and expendable materials as well as: 4.1. Damaged product caused by inappropriate transport and store conditions, wrong connection, operation in abnormal (off-design)
Page 9
We draw your attention to the fact that there can be some changes in this instruction due to the product consistent technical improvement. You can always download our latest versions at www.purelogic.ru w w w. p ure lo g i c .r u Contacts...