This device is safe and complies with the current regulations. If, however
the device is used for purposes other than those intended or operated by
unskilled personnel, risk of serious/life threatening injury may occur!
The below instructions must be strictly followed:
1. Read the enclosed documentation before using the device for the
first time. All safety regulations included in the enclosed manual
must be complied with.
2. This device may only be operated by specially trained personnel.
The customer must ensure that unauthorised personnel do not ap-
proach the machine on which the device is being used.
3. This device may only be used for the intended purposes.
4. The customer is not allowed to make any modifications on the de-
vice unless prior written approval given by Mersen France Amiens.
5. The device must not be used in case of deterioration or in case of
lack of maintenance. Mersen France Amiens may not be held re-
sponsible of any damage and/or injury if the customer does not fully
comply with these safety instructions.
MEASURING TOOLS
CL-Profiler Operating
Instructions
Safety Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL-Profiler and is the answer not in the manual?

Questions and answers

Summary of Contents for Mersen CL-Profiler

  • Page 1 Mersen France Amiens. 5. The device must not be used in case of deterioration or in case of lack of maintenance. Mersen France Amiens may not be held re- sponsible of any damage and/or injury if the customer does not fully...
  • Page 2: Table Of Contents

    2) Settings ..................5 a - General ................. 5 b - Own logo................6 c – ViRoTi................... 6 d – CL-profiler software update ............. 6 3) Linear measurement..............7 a - Slider..................7 b - Y-scale.................. 7 c - Recording ................7 d - Save data................
  • Page 3: I) Introduction

    3 of 15 I) Introduction CL-Profiler is an instrument that must be used in combination with a PC, laptop or mini-PC. The instrument records movements of a probe as a function of time. CL-Profiler is usable for different profile applications but is specially developed for commutators and slip rings profiling.
  • Page 4: Iii) Registration

    CL-Profiler operating instructions page 4 of 15 III) Registration To start the CL- Profiler software, click on the Windows start menu, go to “programs” and select “CL- Profiler”. You can also use a shortcut on the desktop. If the software is unregistered a pop-up will appear for registra-...
  • Page 5: Iv) Software Use

    CL-Profiler operating instructions page 5 of 15 IV) Software use To start the CL-Profiler software, click on the Windows start menu, go to “Programs” and select “CL- Profiler”. If installed, You can also use the shortcut on the desktop. The main screen looks as follows: 1) Language selection First select your language via menu (1).
  • Page 6: B - Own Logo

    (C). d – CL-profiler software update To update the software of your probe(s) , click the ‘Check CL- profiler for USB software up- date’.
  • Page 7: Linear Measurement

    CL-Profiler operating instructions page 7 of 15 3) Linear measurement Click on button (3) to open the linear measurement screen: a - Slider On the left side, the slider (1) indicates the current location of the sensor, in the centre or at the end of the range. The scale will become narrower when the middle point (zero) is approached.
  • Page 8: D - Save Data

    CL-Profiler operating instructions page 8 of 15 To start or stop recording, click on the “START” or “STOP” buttons (4). When recording is busy, a red blinking indicator is shown on the bottom right hand side of the screen. d - Save data When a measurement is finished, it can be saved with the “Save”...
  • Page 9: G - Cursors

    CL-Profiler operating instructions page 9 of 15 Click on button (17) “Reset scale” to reset the scale like it was before modification. The peak to peak indicator (11) shows the difference between maximum and minimum of the whole curve. The “peak to peak zoom” indicator (12) shows the difference between maximum and minimum of the zoomed area (in the example it’s the same).
  • Page 10: Open Saved Files

    CL-Profiler operating instructions page 10 of 15 when it’s too high. If the speed is too high, it will be impossible to save the data because it is not reliable. During recording, the graph shows the real time sensor value, which also includes the peaks between the bars.
  • Page 11: A - Add Curves

    CL-Profiler operating instructions page 11 of 15 a - Add Curves Press ‘Add curve’ (1) to add new curves. They will appear in the small window on the left (2). You have the possibility to add up to a maximum of 10 curves.
  • Page 12: F - Other Buttons

    To use this tool you need: - two free USB ports on your computer - two CL-profiler probes or one CL-profiler and one ViRoTi probe. This function can only work on condition that the measure part “A” is wider than the wide of the groove “B”, including the chamfers Note: Before using this tool you need to update the probe software.
  • Page 13: A - How To Use

    CL-Profiler operating instructions page 13 of 15 a – How to use Place the probes radial, with an ax- ial distance “C”, on your slip ring or your collector. To start the profiling both probes must be located on your measure part of the slip ring or collector, and not in the groove.
  • Page 14: V) Maintenance

    The warranty period is valuable for 1 year starting on the invoice date. Damage due to incorrect or inexpert handling is excluded from the war- ranty. The CL-profiler probe must be placed as radial as possible especially on commutators. Angled probe position, can cause to damage. The ballpoint tip diameter must be: for mica slots: approximately 4 times larger then the full width of the mica slot including the chamfers.
  • Page 15: Vii) Technical Data

    CL-Profiler operating instructions page 15 of 15 VII) Technical data - Interface: USB - Dimensions: 8 mm diameter - Weight: 0,1 Kg - Max operating temperature: 40°C - Max Storage temperature: 50°C - Measurement range: +/-2,5mm - Max. variation speed to be measured: 120/40Hz...