Panasonic KX-TG1061M Service Manual page 73

Telephone equipment
Hide thumbs Also See for KX-TG1061M:
Table of Contents

Advertisement

11.7.1.2. Cordless Handset
First, operate the PC setting according to The Setting Method of JIG (Cordless Handset)(P.69).
Then download the appropriate data according to the following procedures.
BBIC (FLASH type)
(IC1)
EEPROM (IC3)
X'tal (X1)
Note:
(*3) XX: country code YY: revision number
"XX" and "YY" varies depending on the country version. You can find them in the batch file, PNZZ- mentioned in The Setting
Method of JIG (Cordless Handset) (P.69).
(*4) Refer to Check Point (Cordless Handset) (P.55)
Items
Programming data is stored in memory.
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
System clock
How to download/Required adjustment
1) Make sure to connect the JIG cable, then disconnect the DC
Power in order to download the data.
2) Execute the command "flw480 *********.hex".
3) Connect the DC Power.
4) Press and hold the cordless handset OFF key.
5) While holding down cordless handset OFF key, press the PC
Enter key once.
6) After a few minutes, "Successful upgrade" is displayed on
the PC indicating downloading has finished.
7) Detach the JIG cable, then press cordless handset OFF key
to turn it on.
8) Connect the JIG cable again, and execute the command
"getchk", then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
10) Default batch file: Execute the command "default.bat".
11) Country version batch file: Execute the command
"TGA106XXrevYY.bat". (*3).
12) Clock adjustment: Refer to Check Point (J). (*4).
13) 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4).
1) Change the address "0015" of EEPROM to "55".
2) Default batch file: Execute the command "default.bat".
3) Default batch file (remaining); Execute the command
"TGA106 DEFrevYY.bat". (*3)
4) Country version batch file: Execute the command
"TGA106XXrevYY". (*3)
5) Clock adjustment: Refer to Check Point (J). (*4)
6) 1.8 V setting and battery low detection: Refer to Check Point
(A), (H) and (I). (*4)
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (J). (*4)
73
KX-TG1061M/KX-TG1062M/KX-TGA106M

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tg1062mKx-tga106m

Table of Contents