Сontents Introduction ............................... 3 1 Description and operation of the product ..................3 1.1 Purpose of the product ........................ 3-5 1.2 Technical characteristics ........................ 5 1.3 Product components ........................6-9 1.4 Device and operation of the product ..................9-10 1.5 Means of calculation, instruments and property ..............10 1.6 Marking and sealing ........................
Introduction The current operation manual (OM) is a document containing information about the purpose, the basic parameters and technical characteristics, structure and principle of operation of the shockproof shield with the function of non-lethal stun effect «Scala» (hereinafter - the «product»), the instructions necessary for its safe and correct operation (description and operation, intended use, maintenance, storage and transportation).
Page 4
(by documentary order). 1.1.2 Example of designation recording in order and in other documents: • Shockproof shield with electroshock device function «Skala» «Type 01», SMKP20.00.00.00.000 TS • Shockproof shield with electroshock device function «Skala» «Type 02»...
1.3 Product components 1.3.1 The product consists of («Type 01» – fig.1a, «Type 02» –fig.1b): • impact resistant case (1); • removable electroshock device AIR-107 «SСORPION-A» (350) (2); • built-in electric shock device «handle-shocker» (3) - «Type 02»; • a trap (4) designed to install an electroshock device AIR-107 «SСORPION-A» (350) («Type 01»)and to ensure reliable electrical contact.
Page 7
1.3.2 On the outer side of the case there are located («Type 01» – fig.2a, «Type 02» – fig.2b): • conductive foil (5) with the electrodes (6); • glass (7) between the electrodes for additional isolation; • insulating film (not shown); •...
Page 8
fig.3 fig.4 fig.5 1.3.4 On the inner side of the product «Type 02» there are located (fig. 4): • handle (8) and a brace (9) designed to hold the product; • shock absorber (11) designed for additional internal insulation of the product; •...
1.3.6 On the «handle-shocker» (12) in the «Type 02» case (with its own built-in electroshock device) there are (fig 6): • safety lock (charge indicator) (15) that excludes accidental activation of the «handle- shocker»; • the «start» button; • the battery case (17). 1.3.7 The content of precious materials and nonferrous metals in the product does not exceed the norm.
1.4.3 An additional fire-resistant coating provides protection against inflammation of the product and users. 1.4.4 Operation procedure of the product is set out in paragraph 2 of the actual OM. 1.5 Measuring instruments, tools and accessories 1.5.1 Measuring equipment, tools and accessories are not used for operation of the product. 1.6 ...
2 Intended use 2.1 Operating restrictions: • ambient temperature - from minus 20°С to plus 40 °С; • ambient air humidity - up to 98 % at plus 25 °С • presence of vapors of flammable liquids and gases in the air. 2.2 ...
Page 12
2.2.2 Preparation for use of the product «Type 02». WARNING! THE NORMAL CONDITION OF THE PRODUCT OF THE «TYPE 02» (OWN ELECTROSHOCK DEVICE) - THE FUSE IS ON (THE FUSE INDICATOR IS OFF). REMOVE THE ESD FROM THE FUSE IMMEDIATELY BEFORE TURNING ON THE ESD. The fuse also serves as a charge indicator.
charged. Before the first use of the product, it is necessary to charge the battery for 8 hours. In the future, before using the product, it is necessary to make sure that the battery is charged. Charge indicator located in the housing (compartment) The battery of its own electric shock device, assesses the degree of charge of the battery, while: •...
pressing the fuse button and make sure that it is lit (blinking) green LED; • to ensure the closest possible contact of the product with the enemy; • click on the «Start» button. WARNING! THE SINGLE IMPACT TIME SHOULD NOT EXCEED 3 SECONDS! FORBIDDEN: •...
Particular attention should be paid to protect the guides of product arrester against moisture and dust. To remove them wipe the product arrester with a soft dry cloth at room temperature. Measures should be taken to prevent damage to the product serial number. 3.2 ...
button. A steady spark discharge should occur between the electrodes on the outside of the product body (on the glass). The sound of the frequency discharge should be smooth (monotone) without audible frequency gaps. When you release the Start button, the discharge should stop. After checking the operability, the product must be put on the safety lock.
SMKP 30.00.00.00.000 OM. 7 Manufacturer’s warranty 7.1 Manufacturer «MARCH GROUP», 125130, Moscow, Clara Zetkin str., 33, build. 12 phone number: +7 (495) 115-62-78 guarantees that the product meets the requirements of the SMKP30.00.00.00.000 RE. provided that the user observes the conditions of operation, transportation and storage.
9 Packing certificate PACKING CERTIFICATE SHOCKPROOF SHIELD WITH NON-LETHAL ELECTROSHOCK EFFECT «SKALA» PRODUCT «SKALA» №______________________ product name designation factory no Packaged_______________ « MARCH G ROUP» L TD______________________________________ manufacturer’s name or code According to the requirements of the current technical documentation _______ r______________ _____________________ ___________________ Warehouse Manage position personal signature clarification of signature...
Need help?