  • Page 1 QUICK 854D Infrared Preheater Instruction Manual Thank you for purchasing our products. Please keep the instruction manual properly for future reference.
  • Page 3: Table Of Contents

    Contents 1. Safety Instructions................1 2. Overview....................2 3. Product Characteristics............... 2 4. Product Specifications.................3 5. Functional Descriptions...............4 5.1. Dimensions................4 5.2. Part Descriptions..............5 5.3. Key Descriptions..............6 5.4. Function Descriptions of the Main Interface......7 6. Connection.................... 8 7. Temperature Settings................8 8.
  • Page 5: Safety Instructions

    1.Safety Instructions CAUTION  During the installation and use of this product, all electrical safety regulations of the country and regions must be strictly observed.  The power supply must be disconnected when disassembling the product. Do not operate with power on. ...
  • Page 6: Overview

    2.Overview This infrared preheater adopts the far-infrared heating principle and non-contact heating method to preheat the PCB, and works with other heating tools such as soldering station or hot air gun to desolder and rework the components of the PCB. 3.Product Characteristics ...
  • Page 7: Product Specifications

    4.Product Specifications Product model 854D Voltage AC 220V/230V Power consumption 400W Heating area 130mm*130mm Heater material Ceramic heater Temperature sensor K-type Thermocouple Preheat temperature range 50~500℃ Temperature stability ±1℃ Sensor measuring range Room temperature ~600℃ Thermometer accuracy ±5℃ Ambient temperature 0~40℃...
  • Page 8: Functional Descriptions

    5.Functional Descriptions 5.1.Dimensions Unit:mm...
  • Page 9: Part Descriptions

    5.2.Part Descriptions Part Descriptions Power switch Preheating area Display part Button External port for K-type sensor RS485 communication port...
  • Page 10: Key Descriptions

    5.3.Key Descriptions Function Descriptions 1.Press in the main interface to switch between CH1, CH2 and CH3. 2.In the setting interface: Return/Cancel. 1.Press in the main interface to turn on/off. 2.In the setting interface : Advance/Save. 3.In the main interface, long press 2S to enter the setting interface.
  • Page 11: Function Descriptions Of The Main Interface

    5.4.Function Descriptions of the Main Interface Symbols Descriptions Symbols Descriptions Display channel. Buzzer off. 1.Red: heating state. 2.Alternately flashing The current set red and black: the set temperature value. temperature is reached. 3.Blue: cooling state. Press to turn off the temperature Buzzer on.
  • Page 12: Connection

    6.Connection 1) Insert the power plug into the power socket consistent with the label value. 2) Turn on the preheater and it will start to heat up. 3) To change the set temperature, adjust the keys on the panel. 4) After a few minutes, the temperature will reach the set value and stabilizes at the set value.
  • Page 13: Menu Settings

    8.Menu Settings Long press to enter the setting menu. 8.1.Channel Settings 1) Press key to select the channel bar, and continue to press key to select the parameter bar. 2) Press "+" or "-" key in the channel bar to select channels; In the parameter bar, set the temperature and press key to save.
  • Page 15: Address Settings

    8.2.Address Settings 1) Press "+" and "-" on the main menu to switch the menu to Address. 2) Press to select the parameter and the parameter turns blue, press "+" or "-" to set the address value, which ranges from 001 to 255. 3) Press to save.
  • Page 16: Buzzer Settings

    8.3.Buzzer Settings 1) Press "+" and "-" on the main menu to switch the menu to Buzzer. 2) Press to select the parameter and the parameter turns blue, press "+" or "-" to turn the buzzer on or off. 3) Press to save.
  • Page 17: Language Settings

    8.4. Language Settings 1) Press "+" and "-" on the main menu to switch the menu to Language. 2) Press to select the parameter and the parameter turns blue, press "+" or "-" to select English and Chinese. 3) Press to save.
  • Page 18: Password Settings

    8.5.Password Settings 1) Press "+" and "-" on the main menu to switch the menu to Password. 2) Press to input the old password (default 000000) and enter the new password setting interface. Press "+" or "-" to change the value, each time you input a value, you need to press to confirm.
  • Page 19: Linkage Settings

    8.6.Linkage Settings 1) Press "+" and "-" on the main menu to switch the menu to Linkage. 2) Double click to select mode 1, M1 turns blue, and press again to confirm. M1: There is no linkage. 3) Press "-" to select mode 2, press , M2 turns blue.
  • Page 21: Temperature Calibration

    Temperature Calibration Note: 1) When the display temperature is consistent with the set temperature, the temperature can be calibrated. 2) Long press "+" and "-" for 2s to enter the temperature calibration interface. For example: a) The product needs to be preheated to 100 ℃, so we set the temperature to 100 ℃.