Manufacturer CAUTION! B.PRO GmbH Type and source of danger P.O. Box 13 10 Potentially hazardous situation which, if not 75033 Oberderdingen avoided, may result in minor or moderate Phone 07045 44-81416 injury. 07045 44-81508 E-mail service@bpro-solutions.com Internet www.bpro-solutions.com NOTICE! Safety precautions...
The air purifier does not pose a direct fire hazard. In case Proper use of fire, wear respiratory protection. All conventional extin- The ION TEC AIR 80 air purifier is intended for cleaning guishing agents can be used. normal indoor air. In continuous operation, the ION TEC AIR 80 ensures a significantly lower aerosol load and inactivates up to 99.7% of filtered viruses and bacteria in...
Use in children’s day care centres and Functional description schools The ION TEC AIR 80 air purifier is a powerful filter system Additional information for children's day care centres for indoor air and reliably removes fine dust, pollen, bacte- and schools ria, viruses, germs, mould spores, nicotine and smoke.
Transport and assembly Afterfilter Transport Filter cell The ION TEC AIR 80 air purifier is delivered on a pallet by a carrier. UV-C lamps Pre-filter Any damage or suspected damage must be noted on the transport documents and countersigned by the carrier.
Position cables away from areas with positioning high footfall. With five-fold air exchange, the ION TEC AIR 80 air purifi- Position the mains cable without loops er is designed for rooms with a surface area of up to 80 m²...
IP20 Relative humidity max. 90 % Operating tempera- 0°C to 40°C, non-condensing ture Illustration 4: ION TEC AIR 80 dimensions Weight/packaged 80 kg / 95 kg Dimensions 355 x 565 x 1130 mm W x D x H Powder-coated, anthracite grey...
Air output-related consumption and noise level data Restaurant (dining area) Canteens Power consumption in Watts in relation to the extraction performance in m³/h and corresponding noise level. Break room (production) Waiting room 200 m³/h 60 Watt 20 dB(A) Restaurant (kitchen area) 300 m³/h 70 Watt 25 dB(A)
➪ WARNING: The operating panel automatically locks after the time specified in the settings! 6.4.4.4 Cleaning interval The default unlocking code is 4321. For changes, see the description of settings in Group settings. Point 6.4.4.9. The cleaning interval symbol is pressed to set the appro- priate group according to air purifier use.
6.4.6 Weekly schedule 6.4.4.9 Unlock code Shows the current child safety lock unlock code and ena- Using the weekly schedule, automatic switch-on and bles the entry of a customized unlock code. switch-off times can be programmed for the air purifier. The current code is displayed in the information field.
By tapping the filter cell symbol, the filter cell operating hours status menu opens. 6.4.8 The home symbol leads back to the start menu. The fan information field shows whether the fan is in oper- ation. 6.4.10 UV-C lamp Symbol grey = fan out of operation Symbol green = fan in operation...
Cleaning and replacement The air purifier cannot be switched on without charcoal pads! The char- coal filter symbol is crossed out in WARNING! red. Danger due to insufficient air After a positive activated charcoal query, the filter cell and purification! UV-C lamps switch on.
Opening the maintenance door The filter inserts can be accessed by removing the maintenance door on the back of the air purifier. WARNING! Risk of injury when the maintenance door is open! Disconnect the mains plug before opening the maintenance door! To open the maintenance door: Always switch off the air purifier at the on/off switch and disconnect the mains cable.
Page 16
Illustration 9: Filter cell removal Illustration 8: Pre- and afterfilter removal A dishwasher may only be used if the crock- ery holders have been completely folded down or removed! Front Carrying handles Insertion buffer Serial number CAUTION! Short-circuit switch Risk of injury from filter cell The filter cell is essentially made of thin- Spray electrodes...
10) After cleaning the filter cell, pre-filter and afterfilter, Insert the new charcoal filter pads. Both pads must insert them again and close the maintenance door. always be replaced together. Lock the maintenance doors after replacing the char- The insertion buffer prevents the incorrect coal filter pads.
The operating hours display must be reset when the Filter cell replacement unit is restarted. If the filter cell is so damaged that it cannot be repaired, it a) By tapping the UV-C lamp symbol in the start must be replaced. menu, the UV-C lamp operating hours status menu Switch off the unit, open the maintenance door and opens.
Filter cell error message Error message Shows a filter cell error. “Filter cell function impaired!” Possible cause Solution - Moisture has not fully - Leave the filter cell to Error message dried after cleaning. dry. - Pre-filter dirty. - Remove and clean pre- “Filter cell not detected!”...
See the Service Information System on the Internet see Point 10. (www.bpro-solutions.com) NOTICE! 10 Support Depending on the environment, the pre-filter B.PRO GmbH may become clogged with dust. The pre- P.O. Box 13 10 filter should be checked for dirt regardless of 75033 Oberderdingen the cleaning intervals.
12.1 Serial number The serial number of the air purifier is specified on the rating plate. 13 Ordering information ION TEC AIR 80 Article number: 575192; 575194 Page 21 of 24...
Need help?
Do you have a question about the ION TEC AIR 80 and is the answer not in the manual?
Questions and answers