5 Product Regulatory Compliance Information ..........27 Product Safety ........................27 Electromagnetic Compatibility (EMC) - Emissions..............27 Electromagnetic Compatibility - Immunity ................27 Power Line Harmonics / Voltage Flicker ................27 Regional EMC Compliance Information ................. 28 MAXDATA PLATINUM 5200 Server Chassis...
Page 4
6 Important Safety Information ..............29 Important Safety Information....................29 Intended Application Uses ..................... 29 Safety Instructions and Information..................29 Checking the Power Cords ....................29 Earth Grounded Socket-Outlets ..................... 30 Before You Remove the Access Cover ................. 30 Fans ............................30 Electrostatic Discharge (ESD) ....................
Page 5
4. Power Module LED Description..................14 5. Power Supply System Output Capability ................. 25 5. Environmental Specifications ................... 25 6. Product Regulatory Compliance Markings ............... 28 7. Regional EMC Compliance Information ................28 8. Safety Symbols ........................ 29 MAXDATA PLATINUM 5200 Server Chassis...
Power supply 650 watt hot-swap redundant 2+1 PFC power supply. Cooling Five hot-swap system fans: three inside the chassis and two on the rear. Two power supply fans. MAXDATA PLATINUM 5200 Server Chassis...
Chassis Front View � � � � � � � � � � Figure 2. Front View Front panel controls and indicators 5.25-inch removable media drive bays Security lock (pedestal configuration) Hot-swap drive carriers Internal drive bays Chassis intrusion switch Diskette drive bay location USB port Front hot-swap system fan access door...
Figure 4. Rack Controls and Indicators A. Hard drive activity LED ID button Power button G. ID LED Sleep button H. LAN #2 activity LED D. LAN #1 activity LED Status LED Reset button Power/sleep LED MAXDATA PLATINUM 5200 Server Chassis...
Page 10
Table 2. LED Description LED Name Color Condition Description Hard drive activity Green BLINK Hard drive activity Amber Fault No activity LAN#1 activity Green Linked Green BLINK LAN activity Disconnected LAN#2-Link/Act Green Linked Green BLINK LAN activity Disconnected Status LED Green System ready Green...
I/O ports* Power supply module status LED (Green LED means proper operation)* AC module Power Good LEDs (AC1, AC2, ACR; lit means proper operation) Power supply modules * Items shown may different in your chassis. MAXDATA PLATINUM 5200 Server Chassis...
Chassis Side View � � � � � � � � � � � Figure 6. Chassis Side View 5.25-inch removable media drive bays Diskette drive* 5.25-inch hard drive bays Hot-swap fan 5 Hot-swap fan 4 Hot-swap fan 3 PCI Area Duct Processor Area Duct Hot-swap fan 2 Hot-swap fan 1...
The 650 watt, dual-line cord, 2+1 redundant power supply is auto ranging for either 100-120 VAC or 200-240 VAC. The MAXDATA PLATINUM 5200 Server Chassis Hot-Swap, Redundant Power ships with two power modules and a blank filler installed. A third power module (includes a second power cable) can be ordered as an accessory .
Table 4. Power Module LED Description LED Name Color Condition Description Power Module Green Power supply DC outputs ON and OK Green BLINK AC power present/Only Standby outputs ON Amber Indicates one of these conditions: • No AC power to this power supply module •...
A variety of lock sizes can be accommodated by the .270 inch (7 mm) diameter loop. The front bezel has a two-position lock to prevent access to the hard drives and the interior of the chassis. � � Figure 8. Mechanical Locks Front bezel locked Front bezel unlocked MAXDATA PLATINUM 5200 Server Chassis...
3. You are now ready to attach a monitor, keyboard, and mouse to your server, and turn it on. � � � Figure 9. Installing the Chassis Feet Screw hole Chassis foot Workbench Screw (M4 round head) MAXDATA PLATINUM 5200 Server Chassis...
Install into a Rack (Rack Mode) NOTE Your chassis is designed to be compatible with the EIA-310-d rack standard. Be sure to select a rack cabinet enclosure that is EIA-310-d compliant. 1. Fully extend the rails. 2. Remove the smallest and inner-most rail. 3.
Page 19
6. Hold the chassis so the rails on the chassis engage the rails in your rack. You will need someone to help you at this point. 7. Disengage the locking tab on each rail and slide the server into the rack. Figure 12. Installing the Server into a Rack MAXDATA PLATINUM 5200 Server Chassis...
Do not slide board over any surface. For proper cooling and airflow, always install the access cover before turning on the server. Operating it without the cover in place can damage system parts. MAXDATA PLATINUM 5200 Server Chassis...
Replacing Fans The chassis contains five replaceable hot-swap system fans. Your replacement fan should be the same size and type as the fan you are removing. The redundant fans used by the power supply are not replaceable. In the event of a power supply fan failure, you must replace the power supply housing.
Replacing the Power Supply WARNINGS Hazardous conditions, power supply: Hazardous voltage, current, and energy levels are present inside the power supply. There are no user-serviceable parts inside it; servicing should be done by technically qualified personnel. MAXDATA PLATINUM 5200 Server Chassis...
Hot-Swapping a Power Supply CAUTION Two hot-swap power modules must be installed and working when a module is removed. A single working module may not provide enough power for the system, leading to an immediate shutdown of the system. 1. Grasp the handle with your right hand, press the latch with your thumb. 2.
Operational after a 18” free fall, although cosmetic damage may be pre- sent. Packaged Acoustic noise 55 dBA in a typical office ambient temperature (65-75 °F). Your selection of peripherals may change the noise level. Electrostatic discharge (ESD) Tested to 15 kilovolts (kV); no component damage. MAXDATA PLATINUM 5200 Server Chassis...
Electromagnetic Compatibility - Immunity European EN55024: 1998 Union International CISPR 24: 1st Edition Korea MIC Notice 1997-41 Russia GOST-R 50628-95 Power Line Harmonics / Voltage Flicker European Union EN61000-3-2 / EN61000-3-3 International IEC61000-3-2 Japan JEIDA MAXDATA PLATINUM 5200 Server Chassis...
Table 6. Product Regulatory Compliance Markings Country Markings on Product or Packaging Marking Description European Union Declaration of Conformity Mark / Nordics Germany System Safety Compliance Mark Regional EMC Compliance Information Table 7. Regional EMC Compliance Information Country Compliance Information FCC Verification Notice (Class A) This device complies with Part 15 of the FCC Rules.
<HAR> (harmonized) or VDE certified cordage to comply with the chassis’ safety certifications. – The power supply cord(s) is the main disconnect device to AC power. The socket outlet(s) shall be near the equipment and shall be readily accessible for disconnection. MAXDATA PLATINUM 5200 Server Chassis...
Earth Grounded Socket-Outlets WARNING To avoid electrical shock, the system power cord(s) must be plugged into socket-outlet(s) that is provided with a suitable earth ground. The system will be provided with the following marking: Connect only to properly earthed socket outlet. Before You Remove the Access Cover WARNING To avoid personal injury or property damage, the following safety instructions apply whenever...
The equipment rack must provide sufficient airflow to the front of the system to maintain proper cooling. The rack selected and the ventilation provided must be suitable to the environment in which the system will be used. MAXDATA PLATINUM 5200 Server Chassis...
Backup Battery The lithium battery on the baseboard powers the real-time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) might be incorrect.