Hide thumbs Also See for SKR800W:

Advertisement

Quick Links

SKE RADAR SKR800W
Manual Book
(Ver: 1.0)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SKR800W and is the answer not in the manual?

Questions and answers

Summary of Contents for SKE SKR800W

  • Page 1 SKE RADAR SKR800W Manual Book (Ver: 1.0)
  • Page 2: Table Of Contents

    Catalogue Warranty and service scope of radar level sensor ................Unpacking inspection and precautions ......................3 Unpacking inspection..........................3 Precautions .............................. 4 Storage and transportation .......................... 4 Storage conditions ........................... 4 Transport the product to the measuring place ..................4 Product introduction ............................
  • Page 3: Warranty And Service Scope Of Radar Level Sensor

    1. Warranty and service scope of radar level sensor The warranty period of the radar level sensor is one year from the date of delivery, and the warranty period of repair and maintenance is half a year. This warranty is only limited to the users of the original buyer or the designated dealer, and does not apply to users who use it wrongly for human reasons, transform, neglect or damage it due to accidents and abnormal use.
  • Page 4: Precautions

     Check whether the radar sensor housing is intact and observe  Check the random items against the packing list  Check whether the specifications, models and accessories are correct and complete according to the packing list of the radar level sensor. If there is any problem, please contact the customer service center in time for replacement.
  • Page 5: Product Introduction

    4. Product introduction 4.1 Product Overview 76-81ghz frequency modulated continuous wave (FMCW) radar products (also known as millimeter wave radar) adopt the millimeter wave band with higher frequency than Ku band radar. They have important applications in long-range target detection, long-range imaging, multispectral imaging in strong smoke and dust environment, and can detect smaller targets than microwave radar and achieve more accurate positioning, with higher resolution and stronger confidentiality.
  • Page 6: Technical Parameters

    4.2 Technical parameters Radar Level Two wire system Max range 8m、15m Error ±1‰FS、±2‰FS、±5‰FS Migration ±9.9m Signal output 4~20mA/Modbus Power supply DC 24V ( 22V~30V ) Ambient temperature -20℃~+70℃ Ambient humidity (0%~95%)RH Protection IP67 Display Mobile Phone APP ϕ76mm×107mm Weight 0.35kgs Sizes 4.3 Application 4.3.1 Measured medium...
  • Page 7: Outline Structure Of Radar Level Sensor

    5. Outline structure of radar level sensor 5.1 Outline structure diagram Diagram1  P1 diagram for sizes 6. Terminal block of radar level sensor  The radar level ga sensor leads out two power lines, the red one is connected to the positive pole of the power supply, and the blue one is connected to the negative pole of the power supply.
  • Page 8: Description Of Radar Commissioning Parameters

    7. Description of radar commissioning parameters 7.1 Radar level sensor mobile app main interface P2 APP main interface 7.2 Waveform interface...
  • Page 9: Radar Menu

    P3 waveform interface 7.3 Radar menu 7.3.1 User menu Measure range Migration 4mA position 20mA position Blind zone Basic parameters Damping time Device address Baud rate Backups Restore...
  • Page 10: Setting Range And Definition Of Basic Parameters

    7.3.2 Setting range and definition of basic parameters  Basic settings: Range ( 500~50000) mm: It depends on the working condition; Indicates the longest distance that the level sensor can measure. Migration(-9999~9999)mm:It depends on the specific working conditions 4mA Position:4mA Level corresponding to current output,Unit mm 20mA Position:20mA Level corresponding to current output,Unit mm Blind zone:The range is 200mm to the measuring range, which is set according to the specific working conditions...
  • Page 11: Radar Installation And Commissioning

    8. Radar installation and commissioning 8.1 Preparations before installation  Understand the installation location, structure, measuring range  Required tools: DC 24V power supply, etc  After the tools are ready, unpack the products and check the packing list to determine whether the materials are complete.
  • Page 12: Software Configuration Description

     ladder and grid container treatment P6 Ladder and Grid container  Wall hanging and grid container treatment P7Wall hanging and Grid container 8.3 Software configuration description  Instrument connection Connect the power line to the DC 24V terminal of the instrument; Pay attention to the positive and negative poles, and do not connect them reversely.
  • Page 13 Directly click the device name to be set to enter the main interface, as shown in the following figure.
  • Page 14 Click the "curve" or "setting" button at the bottom of the screen to enter the echo curve interface and parameter setting interface respectively. Click the "setting" button here to enter the parameter setting interface, as shown in the following figure. Click "basic parameters"...
  • Page 15: Maintenance And Repair

    Set the "range" according to the working condition, directly click the following digital input box to modify, and the other parameters are modified in the same way. After the parameters are modified, you need to click the "set" button to set it before it takes effect.
  • Page 16: Trouble Shooting

     Radar sensor should be detected regularly. (the detection cycle is determined by the user according to the specific situation) 10. Trouble Shooting Trouble Cause Solution Power supply Check whether the DC 24V voltage and No display error current meet the requirements. Wiring error Check whether the wiring is correct.

Table of Contents