Advertisement

Quick Links

Installation Manual
SensorLinx™ Heat Meter Installation Guide
Version 2.0.2
WFS-0020
WFS-0030
WFS-0070
WFS-0130
WFS-0400
HBX Control Systems Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SensorLinx WFS-0020 and is the answer not in the manual?

Questions and answers

Summary of Contents for HBX SensorLinx WFS-0020

  • Page 1 Installation Manual SensorLinx™ Heat Meter Installation Guide Version 2.0.2 WFS-0020 WFS-0030 WFS-0070 WFS-0130 WFS-0400 HBX Control Systems Inc.
  • Page 2: Table Of Contents

    The HBX Sensorlinx™ Metering System is a microprocessor based controller and as such is not to be regarded as a safety (limit) control. Please consult and install the heating or cooling appliance in accordance with the manufacturer’s recommendations.
  • Page 3: Receipt And Inspection

    NAME AND PIN INFORMATION The label displays the serial number which will match the serial number on your actual HBX Sensorlinx™ Sensor, the lot number, the bar code and the products PIN. WFS-0 Sync Code: AFLO1234...
  • Page 4: Description And Main Parts

    Sensor Clip: Secure the sensor inside the flow pipe. Clip must be flush with the flow pipe. EPDM Flat Washer: Washer must be placed inside before installation. Flow Tube Union: Brass Union Name Plate: Contains sensor Sync-Code © 2021 HBX Controls...
  • Page 5: Technical Data And Dimensions

    TECHNICAL DATA AND DIMENSIONS No pipe tape/dope should be used on threads. WFS-0014 WFS-0030 WFS-0070 WFS-0130 WFS-0400 137.5 3.23 3.46 5.08 5.41 7.09 L/MIN 1.4 -14 3-30 7-70 13-130 20-400 0.36-3.69 0.70-7.92 1.84-18.49 3.43-34.34 5.28-105.67 Flow Tube Union Pipe Pressure Part Flow Tube House Torque...
  • Page 6: Flow Sensor Technical Specifications

    Selection of flow sensor to minimise pressure drop at 1 cSt p [mbar] [psid] 1000 14.5038 Head loss: 1.4504 0.1450 0.0145 0.0015 1000 Q [l/min] Q [gpm (US)] 0.026 0.13 1.32 2.64 13.2 0 Q min Tmax = Peak temperature © 2021 HBX Controls...
  • Page 7: Device Wiring

    DEVICE WIRING 24 VAC R (Red) 24 VAC C (White) Ground (Blue) Thermistor Input (Yellow) 24 VAC Triac Output, 0.5A Max (Green) Modulating Output (Black) 1/2: Input Power: This input is to power the sensor. 1 Amps at 24VAC is required to power this device.
  • Page 8 DEVICE WIRING Standard Flow and Temperature Sensor Installation 24 V AC Ground Ensure the R and W wires from each unit are hooked up to the same corresponding wire. Do not cross wire! 120 VAC © 2021 HBX Controls...
  • Page 9: Installation

    INSTALLATION Sensor can be mounted Vetically or horizontally within a 180 arc. Sensor CANNOT mounted pointing below this line or downwards. No pipe tape/dope should be used on threads. EscriPtion Install the temperature and pressure sensor in a location that will be easy to perform periodic maintenance.
  • Page 10 INSTALLATION Standard Flow and Temperature Sensor Installation Ground Must be grounded to Pipe Installation with Optional Solenoid Valves Ground Must be grounded to Pipe © 2021 HBX Controls...
  • Page 11: Connecting To A Network (Android)

    CONNECTING TO A NETWORK (ANDROID) WiFi Setup 9:41 AM 100% WiFi Setup --°F 9:41 AM 100% --°F Add Name Here Add Name Here CHOOSE A NETWORK CHOOSE A NETWORK Home Network Home Network ThermoLinx ThermoLinx Network SSID Home Network Network SSID Home Network 1234 Press the SET button on the Flow Sensor, and wait...
  • Page 12 At this point you are now ready to add the SensorLinx device to your location. Connections can only be made to a 2.4GHz network. Home network name cannot contain more than 30 characters. The password should not contain any special characters. © 2021 HBX Controls...
  • Page 13: Connecting To A Network (Ios)

    CONNECTING TO A NETWORK (IOS) WiFi Setup 9:41 AM 100% --°F Add Name Here CHOOSE A NETWORK Home Network ThermoLinx Network SSID Home Network Press the SET button on the BTU Flow 1234 Sensor, and wait 60 seconds. If the red LED Network Password light (Wi-Fi) on the sensor is not blinking, Connect to WiFi Now...
  • Page 14 At this point you are now ready to add the SensorLinx device to your location. Connections can only be made to a 2.4GHz network. Home network name cannot contain more than 30 characters. The password should not contain any special characters. © 2021 HBX Controls...
  • Page 15 Solid Green Only: Incorrect password Solid Red and Green: ThermoLinx is connected to your Wi-Fi but your network port 1314 is closed and not allowing communication to the HBX server, please contact your internet provider to rectify this. Connections can only be made to a 2.4GHz network.
  • Page 16: Adding Sensors To The Thermolinx App

    9:41 AM 100% Devices 83° 9:41 AM 100% Room Name Locations Add Name Here No devices! Leave Blank if device already named Room Temp Target Sync Code °F ABTU-1234 None Password 1111 Select Location Add Location Building © 2021 HBX Controls...
  • Page 17: Navigating The Thermolinx App

    NAVIGATING THE THERMOLINX APP Relay Closed: Indicates if the relay is closed to activate a pump or valve. Setup: Adjust Relay output, Fluid, and thermistor settings. Sensor Info: Provides sensor type and unit serial number. Alarms: Set alarm notification for flow and temperature. Temperatures: View temperature and flow data in real time System Status: View Current Flow measurement and lifetime Heat accumulation for days, week, monthly, and yearly.
  • Page 18: Limited Warranty

    In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover or other incidental, consequential or indirect damages arising out of the installation, maintenance, commissioning, performance, failure or interruption of an HBX product, however caused and on any theory of liability.
  • Page 19 ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________...
  • Page 20 Toll Free Technical Support: +1 (855) 410 2341 Need Help? Call Tech Support Toll Free: 1 (855) 410-2341 Scan for Manual support@hbxcontrols.com HBX Control Systems Inc. 4516 - 112 Avenue SE © HBX Control Systems Inc. 2012 Calgary, AB Canada T2C 2K2...

Table of Contents