Download Print this page

ZBA ZLIM-211 Manual

Programming barcode

Advertisement

Quick Links

ZBA Inc
.
ZLIM-211 Programming barcode manual
V1.04
V1.04
ZBA, Inc.
Page 1 of 25
94 Old Camplain Road
Hillsborough, NJ 08844
Ph: 908-359-2070
Fax: 908-595-0909
Web: http://www.zbausa.com/

Advertisement

loading
Need help?

Need help?

Do you have a question about the ZLIM-211 and is the answer not in the manual?

Questions and answers

Summary of Contents for ZBA ZLIM-211

  • Page 1 ZBA Inc ZLIM-211 Programming barcode manual V1.04 V1.04 ZBA, Inc. Page 1 of 25 94 Old Camplain Road Hillsborough, NJ 08844 Ph: 908-359-2070 Fax: 908-595-0909 Web: http://www.zbausa.com/...
  • Page 2 The ZLIM-211 is ultra-compact size scan engine, and built in high performance CCD, The ZLIM-211 is ideal for OEM applications where space is limited for scanner integration in both portable and fixed devices, including hand held terminals, PDAs, PC and cell phone peripherals, lottery terminals, time and attendance terminals, ski-pass, automated sorting machines and more.
  • Page 3 ZBA Inc Chinese post code identifier code UPC-A identifier code UPC-E identifier code EAN-13 identifier code EAN-8 identifier code Codabar identifier code Code 128 identifier code Code 93 identifier code MSI identifier code Industries 2 of 5 code Standard 2 of 5 code...
  • Page 4: System Function Setting

    ZBA Inc , Parameter setting (All items mark with grey shading indicates the default value) System Function setting Barcode Value Description Remark Start Of Configuration End Of Configuration Reset (return to factory default) Abort(exit programming mode(no update) Display firmware version...
  • Page 5 ZBA Inc Very long sound GR15 duration (500 msec) LOUD VOLUME GR20 (50/50 duty) MEDIUM VOLUME GR21 (30/70 duty) Slight volume GR22 (20/80 duty) Led/Beep after transmission.Use this bar code to indicate a LB00 "good read" after a bar code has been successfully decoded.
  • Page 6 ZBA Inc scanner is still active after the data is transmitted, but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again.. Alternate mode. This scanner will light up SM04 when press the scanner trigger switch once.
  • Page 7: Rs-232C Interface Setting

    ZBA Inc Laser sleep mode off, The laser timeout programming bar codes set the time for switching the laser off if the scanner isn't LS00 used. Laser sleep time 5 second LS01 只有效給 Auto Laser sleep time 10 second scan mode...
  • Page 8 ZBA Inc Baud Rate 19200 BR01 Baud Rate 9600 BR02 Baud Rate 4800 BR03 Baud Rate 2400 BR04 Baud Rate 1200 BR05 Baud Rate 57600 BR08 Baud Rate 115200 BR09 None handshaking HP01 ACK/NAK HP02 Xon/Xoff HP03 RTS/CTS HP04 Even parity...
  • Page 9 ZBA Inc ACK/NAK response time 300ms RT01 ACK/NAK response time 2s RT02 ACK/NAK response time 500ms RT03 ACK/NAK response time 3s RT04 ACK/NAK response time 1s RT05 ACK/NAK response time 5s RT06 ACK/NAK response time infinity RT07 1 stop bit...
  • Page 10 ZBA Inc The Symbologies CODABAR Codabar enable RC02 CODABAR disable RD02 Codabar start/stop character CB05 transmission-----none Codabar start/stop character CB06 transmission-----A,B,C,D Codabar start/stop character CB07 transmission-----DC1~DC4 Codabar start/stop character CB08 transmission-----a/t,b/n,c/*,d/e Codabar maximum length setting CB09 Codabar minimum length setting...
  • Page 11 ZBA Inc Code39 Code 39 enable RC01 Code 39 disable RD01 Code 32 enable RC13 Code 32 disable RD13 Code 39 data redundant check=off DC00 Code 39 data redundant check=1 DC01 Code 39 data redundant check=2 DC02 Standard code 39...
  • Page 12 ZBA Inc Code 32 (Italian pharmacy)transmit “A” 3912 character Code 32 (Italian pharmacy)without transmit ”A” 3913 character Code 93 Code 93 enable RC08 Code 93 disable RD08 Code 93 data redundant check=off DC30 Code 93 data redundant check=1 DC31 Code 93 data redundant check=2...
  • Page 13 ZBA Inc Code 128 data redundant check=off DC40 Code 128 data redundant check=1 DC41 Code 128 data redundant check=2 DC42 Code128 FNC2 concatenation enable 1801 Code128 FNC2 concatenation disable 1802 No check character 1803 Calculate but not transmitt 1804 Calculate and transmitt...
  • Page 14 ZBA Inc MSI/PLESSY MSI enable RC14 MSI disable RD14 MSI data redundant check= off DC70 MSI data redundant check=1 DC71 MSI data redundant check=2 DC72 MSI/PLESSY maximum length setting MS01 MSI/PLESSY minimum length setting MS02 MSI/Plessy double check digit calculate but...
  • Page 15 ZBA Inc CODE 11 one check digit verification 1103 Code 11 two check digit verification 1104 Two Check for code 11 check digit if code 1105 length is greater than 10 character Disable verification 1106 Code 11 check digit transmitted...
  • Page 16 ZBA Inc ITF 2 of 5 check digit calculate and transmit IT04 ITF 2 of 5 check digit calculate but without IT05 transmit ITF 2 of 5 one Fixed length setting IT06 ITF 2 of 5 two Fixed length setting...
  • Page 17 ZBA Inc EAN-8 ENABEL UE08 UPC/EAN addendum off UE09 Addon 5 only UE10 Addon 2 only UE11 Force UPC-E to UPC-A format enable UE13 Force UPC-E to UPC-A format disable UE14 Force UPC-A to EAN-13 format enable UE15 Force UPC-A to EAN-13 format disable...
  • Page 18: Data Editing

    ZBA Inc Transmit UPC-A leading character enable UE27 Transmit UPC-A leading character disable UE28 Addon format with separator UE30 Addon format without separator UE31 EAN/UPC +addon (none mandatory) UE32 force EAN-8 to EAN-13 format enable UE44 force EAN-8 to EAN-13 format disable UE45 EAN-13 first “0”...
  • Page 19 ZBA Inc CODABAR identifier code setting CI08 CODE 128 identifier code setting CI09 CODE 93 identifier code setting CI10 MSI identifier code setting CI11 Industrial 2 of 5 Identifier code setting CI15 Code 11 Identifier code setting CI16 Standard 2 of 5 Identifier code setting...
  • Page 20 ZBA Inc Inter character delay 2ms IC05 Inter character delay 100 msec IC06 Inter character delay 90 msec IC07 Inter message delay 0 ms IM01 Inter message delay 100 ms IM02 Inter message delay 500 ms IM03 Inter message delay 1000 ms...
  • Page 21 ZBA Inc Standard 2 of 5 STD 2 of 5 code enable RC22 STD 2 of 5 code disable RD22 STD 2 of 5 code maximum length D051 setting STD 2 of 5 code minimum length D052 setting Code 39 Full ASCII Table...
  • Page 22 ZBA Inc “ & ‘ V1.04 ZBA, Inc. Page 22 of 25 94 Old Camplain Road Hillsborough, NJ 08844 Ph: 908-359-2070 Fax: 908-595-0909 Web: http://www.zbausa.com/...
  • Page 23 ZBA Inc < > V1.04 ZBA, Inc. Page 23 of 25 94 Old Camplain Road Hillsborough, NJ 08844 Ph: 908-359-2070 Fax: 908-595-0909 Web: http://www.zbausa.com/...
  • Page 24 ZBA Inc V1.04 ZBA, Inc. Page 24 of 25 94 Old Camplain Road Hillsborough, NJ 08844 Ph: 908-359-2070 Fax: 908-595-0909 Web: http://www.zbausa.com/...