Therma-Stor Quest PowerDry 4800D DRY 150 Pro LP Installation, Operation And Maintenance Instructions

Therma-Stor Quest PowerDry 4800D DRY 150 Pro LP Installation, Operation And Maintenance Instructions

Advertisement

Quick Links

Quest PowerDry 4800D Pro LP/NG
Quest DRY 150
Installation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions
– Read and Save These Instructions –
– Read and Save These Instructions –
This manual is provided to acquaint you with
the 4800D so that installation, operation
and maintenance can proceed successfully.
Ultimate satisfaction depends on the quality
of installation and a thorough understanding
of this equipment. This unit is built around
tested engineering principles and has passed
a thorough inspection for quality of workman-
ship and function.
Quest PowerDry 4800D Pro LP/NG:
• 3032 Pints/day AHAM
• 4800 CFM process airflow
• Dries in temperatures to 140°F
• Reaches dew points as low as -40°F
• 48"W x 120"L x 74"H
• 1600 lbs. (Standard machine weight only)
• 240 volt, 70 amp single phase
• Propane or Natural Gas Fired
FOR YOUR SAFETY:
gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Refer to this manual. For assistance or additional
information, call a qualified installer, service agency or
the gas supplier.
FOR YOUR SAFETY:
try to light any appliance. DO NOT touch any electrical
switch. IMMEDIATELY call your gas supplier from a
location away from the device. If the gas supplier cannot
be reached, call the fire department.
quest
quest
Specifications subject to change without notice.
DO NOT store or use
If you smell gas: DO NOT
1
Quest PowerDry 4800D
Pro P/N
(with Frame)
PN 4028204 Propane
PN 4030630 Nat Gas
Quest PowerDry 4800D
Pro P/N
(without Frame)
PN 4029194 Propane
PN 4030640 Nat Gas
4201 Lien Rd.
Phone 608-237-8400
Madison, WI 53704
Toll-Free 1-866-933-7486
www.QuestProtect.com
sales@QuestProtect.com
TS-650/651
08/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Quest PowerDry 4800D DRY 150 Pro LP and is the answer not in the manual?

Questions and answers

Summary of Contents for Therma-Stor Quest PowerDry 4800D DRY 150 Pro LP

  • Page 1: Introduction

    Quest DRY 150 Quest PowerDry 4800D Pro LP/NG Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions – Read and Save These Instructions – – Read and Save These Instructions – This manual is provided to acquaint you with the 4800D so that installation, operation and maintenance can proceed successfully.
  • Page 2 Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions GENERAL HAZARD WARNING MISES EN GARDE GENERALES Failure to comply with the precautions and Le non-respect des mises en garde et des instructions fournies avec ce radiateur peut entrainer la mort, de graves blessures et des pertes instructions provided with this unit can result materielles ou des dommages a la propriete resultant d’un incendie, in death, serious bodily injury and property loss...
  • Page 3: Table Of Contents

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions Table of Contents 8. Trouble Shooting ........16 Introduction ............1 9. Service Parts ..........17 1. Specifications ..........4 Warranty ...........18 2. Operation ...........4 Serial No.__________________________________ 2.1 How the Quest Dry PowerDry 4800D Pro P/N Works ....5 Purchase Date_____________________________ 3.
  • Page 4: Specifications

    Quest PowerDry 4800D Pro P/N Quest PowerDry 4800D Pro LP/NG Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions 1. Specifications Part No. 4028204 Propane (with cage) 4030630 Nat Gas (with cage) Part No. 4029194 Propane (without cage) 4030640 Nat Gas (without cage) 240 volt, 70 amps single phase Power Water...
  • Page 5: Powerdry 4800D Pro P/N Works

    Quest PowerDry 4800D Pro P/N Quest PowerDry 4800D Pro LP/NG Installation, Operation and Maintenance Instructions Installation, Operation and Maintenance Instructions Principle of Operation adsorption. This process is done on a continuous basis, providing a constant drying process. The two air streams (process and Cabinet Divider reactivation) are separated by seals, which and Seals...
  • Page 6: Location

    The same can be said of excess bends in the ducting. Multiple duct sizes are used on the Quest PowerDry 4800D Pro P/N (see below). All ducting materials are available from Therma-Stor LLC (see accessories list in Section 1).
  • Page 7: Avoiding Secondary Damage

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions Process inlet: 18” flex duct. To attach flex ducts to the process air intake, push the wire of the first few loops beyond the 2 holes in the duct collar. Push the metal rod through the duct and duct collar piercing the duct in two places. Tape or a hose clamp can be used to create an airtight seal.
  • Page 8: Operation Instructions

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions 4 Operating Instructions Refer to the Operating Instructions label located next to the control panel of your Quest PowerDry 4800D Pro P/N. User-supplied power cord, cord grip, and branch protection appropriate for the electrical load must be supplied.
  • Page 9: Control Panel

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions 3. Close gas supply shut off valve. 4. Turn main disconnect switch to OFF. 5. Disengage power source. 6. Lock out power source. 7. Disconnect power cable. 8. Disconnect propane or natural gas source. 5 Control Panel 5.1 Main Disconnect The main disconnect switches power from the source to the panel.
  • Page 10: Hour Meter

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions 5.5 Hour Meter The hour meter will run whenever the Quest PowerDry 4800D Pro P/N is operating. This hour meter measures the cumulative time of operation in one-tenth hour increments. This meter is often used to verify hours on a job or to schedule maintenance.
  • Page 11: Drive Motor

    Inspect the face of the media to see that no surface damage has occurred. If damage is noticed, please contact Therma-Stor at 1-800-533-7533 x8459 for assistance. The rotor should turn smoothly upon the shaft, if not check the support bearings.
  • Page 12: Wiring Diagram

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions STAND STAND STAND BY STAND quest quest 1-866-933-7486 www.QuestProtect.com sales@QuestProtect.com...
  • Page 13 Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions quest quest 1-866-933-7486 www.QuestProtect.com sales@QuestProtect.com...
  • Page 14 Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions MAIN CHASIS FROM PREVIOUS PAGE FROM PREVIOUS PAGE 24VAC INPUTS/RELAY OUTPUTS 120VAC 24VAC NEUTRAL 230RCO REMOVE YELLOW JUMPER TO USE OPTIONAL EXTERNAL DEHUMIDISTAT 3072 3070 YELLOW START/STOP SYSTEM DEHUMIDISTAT 3090 DEHUMIDISTAT 3110 COMBUSTION BLOWER...
  • Page 15 Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions EXPANSION MODULE FROM PREVIOUS PAGE FROM PREVIOUS PAGE 4 24VAC INPUTS/4 RELAY OUTPUTS NEUTRAL 24VAC DM8 24R 4060 PROCESS BLOWER PRESSURE SWITCH (PS3) SPARE SPARE SPARE 120VAC TO IGNITOR DM8 24R FENWALL CONTROLLER SUPPLY POWER/IGNITOR 120VAC...
  • Page 16: Troubleshooting

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions 8 Troubleshooting ELECTRICAL SHOCK HAZARD: Electrical 9 Troubleshooting power must be present to perform some tests; these tests should be performed only by a Refer to section 5.4 regarding interpeting flashing faults. qualified service person.
  • Page 17: Service Parts

    Quest PowerDry 4800D Pro P/N Installation, Operation and Maintenance Instructions 9 Service Parts Item Part No. Description 4020175 Humidity Control 4028010 Magnehelic Gauge 4028013 Thermostat, 350°F 4028015 Ignition Module 4028016 Hot Surface Ignitor 4028033 Inspection Window Glass 6x6 4028559 Inspection Window Glass 4x4 4028626 Process Blower 4028627...
  • Page 18: Warranty

    First Year Warranty: Therma-Stor Products warrants that, for one (1) year the Quest PowerDry 4800D Pro P/N will operate free from any defects in materials and workmanship, or Therma-Stor Products will, at its option, repair or replace the defective part(s), free of any charge.

This manual is also suitable for:

Quest powerdry 4800d dry 150 pro ng