Description

ACL800SUW-BC is a Wiegand biometric reader for access
control applications. It offers storage up to 9500 fingerprints
and programmable Wiegand output (24 to 80 bits).
Configuration of the readers and fingerprint enrollment is done
through ACL800 BioManager software. Connection between
the biometric readers is RS485 and it is used for fingerprint
transfer and configuration.
When used with third party access controllers, the connection
between the biometric readers and the PC is done through
ACL800FL-CONV-W converter (RS485 to TCP/IP). Only one
converter is needed per system (one converter for 1 to
31 biometric readers).
The tamper switch output can trigger the alarm system if an
attempt is made to open or remove the unit from the wall.

Mounting

Figure 1: Mounting instructions
© 2022 Carrier

Wiring

Figure 2: Wiring instructions
12 VDC
Red
GND
Black
A
Pink
B
Violet
Tamp
Blue
Tamp
Green
LG−
Yellow
LR−
Orange
D1
White
D0
Green

Connecting biometric readers to controllers

Connect the lines D0, D1, LR−, LG−, GND and +12V to the
TruPortal controller.
Connect the RS485 line (A, B) to the converter. Connect the
converter in the PC.
Fingerprint enrollment is done from the ACL800 BioManager
software. Connection between the biometric readers and the
PC must be established.
The biometric readers communicate with each other with a
RS485 and with the ACL800 BioManager software through a
converter.
The RS485 line should be configured in the form of a daisy
chain, NOT in a form of a star. Keep the stubs from the RS485
backbone as short as possible (not more than 5 meters).
Only one converter per installation is needed, not per reader.
1 / 6
Red
12 VDC
Black
GND
Pink
A
RS485
Violet
B
Orange
LR−
Yellow
LG−
Green
D0
Wiegand
White
D1
Gray
Tamper
Blue
Tamper
+12 VDC
Ground
A (RS485)
B (RS485)
Tamper
Tamper
LED green −
LED red −
Data 1
Data 0
P/N 1073502-EN • REV B • ISS 07JUL22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACL800SUW-BC and is the answer not in the manual?

Questions and answers

Summary of Contents for Aritech ACL800SUW-BC

  • Page 1 Tamp Blue Tamper Description Tamp Green Tamper ACL800SUW-BC is a Wiegand biometric reader for access LG− LED green − Yellow control applications. It offers storage up to 9500 fingerprints LR− LED red − and programmable Wiegand output (24 to 80 bits).
  • Page 2 RS485 tuning Figure 3: RS485 tuning Terminate both ends of the line with 120 Ohm resistor. Note: The portal can be added automatically with the Search function. If the communication is not established and stable, use the external resistors provided in the hardware kit. Enrollment Figure 4: Enrollment Add Reader...
  • Page 3 Click on Save and the reader icon appears under the Edit reader properties and click Save button. selected portal. Check at event table if the configuration was successful. Delete reader Right-click on the reader and select Delete reader. Right-click on reader and select Check version to see if the reader is online.
  • Page 4 Right click on the fingertip and select enroll. Notes • If more fingerprints are added for one user, all fingerprints will send the same Wiegand code to the controller, the one written in the field User ID (card Number). • Users can be imported from Excel file or from TruPortal.
  • Page 5 Deleting all users from the biometric reader Note: Use this feature when you change or add a reader, if pending tasks are deleted in the software or if there are doubts Right click on the reader and select Delete all users from that fingerprints in the reader memory are not synchronized reader.
  • Page 6 Tamper IP rating Contact information −20 to +50°C Operating temperature Relative humidity 5 to 93% noncondensing firesecurityproducts.com or www.aritech.com Dimensions (mm) 92 x 51 x 25 (metal); 92 x 51 x 27 (ABS) Housing Moulded aluminium Regulatory information Manufacturer PLACED ON THE MARKET BY: Carrier Fire &...

Table of Contents