  • Page 1 Window-Mounted Air Conditioner with Remote, Energystar Sistema de Aire Acondicionado para Instalación en Ventanas, con Control Remoto, Energystar Climatiseur De Type Fenêtre avec Télécommande, Certifié Energystar B07Y2BTPJ3, B07Y2B738L...
  • Page 2 English                                  5 Español                                43 Français                                80...
  • Page 3 3.2 mm Ø 1/8" A (x 1) B (x 1) C (x 1) D (x 1) E (x 1) F (x 2) H (x 1) G (x 1) I (x 1) K (x 2) J (x 1)
  • Page 4 L (x 2) M (x 2) N (x 2) Q (x 2) P (x 7) O (x 4) S (x 10) T (x 2) R (x 2) U (x 2) V (x 1) W (x 1)
  • Page 5: Important Safeguards

    IMPORTANT SAFEGUARDS Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included. When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following: WARNING Do not pierce or burn.
  • Page 6: Grounding Instructions

    Always plug this product directly into a wall outlet/receptacle. Never use with an extension cord or relocatable power tap (outlet/power strip). B07Y2BTPJ3 B07Y2B738L Grounding pin Grounding pin NOTICE For model B07Y2BTPJ3: Plug type is NEMA 6-20 P for 240 V~.
  • Page 7: Intended Use

    SAVE THESE INSTRUCTIONS Intended Use • This product is intended to regulate temperature and humidity indoors. • This product is intended for a fixed installation in a window only. The power cord must be connected to indoor power supply only. This product is not intended for use in bathrooms, laundry areas and similar indoor locations.
  • Page 8: Product Description

    Product Description Main unit RESET TEST RESET TEST Control panel Fresh air vent control Air direction control Air outlet Air inlet Power plug with indicator RESET button TEST button...
  • Page 9 Controls 13 14 16 17 Energy saver button Timer on indicator Main unit display Increase button Decrease button Timer off indicator Sleep button Clean filter button Follow me indicator Follow me button Fan button Lock button On/off button LED button Remote control receiver Clock button Fan speed indicator...
  • Page 10: Window Requirements

    The product is designed to be installed in a standard sash window with the following dimensions: B07Y2BTPJ3 B07Y2B738L A: 31–42" (78.7 – 106.7 cm) A: 28–40.5" (71.1 – 102.8 cm) B: 19.5" (49.5 cm) B: 18.5" (47 cm) For B07Y2BTPJ3 Sash Sash ≥19" ≥19" (48.3 cm) ≥1/2" (48.3 cm) ≥1/2"...
  • Page 11: Installation Considerations

    For B07Y2B738L Sash Sash ≥18" ≥18" (46 cm) ≥1/2" (46 cm) ≥1/2" (1.27 cm) (1.27 cm) Piece of Window wood frame Window frame or or other ≥1/2" other obstacle obstacle (1.27 cm) If your storm window frame does not allow the clearance required, correct by adding a piece of wood as shown the right picture.
  • Page 12 Installation (Remove Cabinet) Step 1: • Remove all transport packaging materials from the cabinet. • Remove the front grille by pulling it on its top. Step 2: • Remove the air filter by pulling it at the bottom edge.
  • Page 13 Step 3: • Remove the 4 front screws. NOTICE Keep this screws. They will be needed later during reassembly. Step 4: • Remove the front panel by pulling it on its bottom edge and then by moving it upwards.
  • Page 14 Step 5: • Disconnect the front panel from the main unit. Press the connector from the top and carefully disconnect both parts. Step 6: • Remove the transport fixing screws from the top of the cabinet. If there are any other screws at the sides so remove them too. NOTICE These screws are not needed any longer.
  • Page 15 Step 7: • Pull the main unit out of the cabinet. Pull it at the grip in the middle of the bottom edge. Step 8: • Remove all transport packaging materials from the inner main unit. Cut through the cable ties with scissors.
  • Page 16 Installation (Top Rail and Side Bracket) • Remove the anti-adhesive paper from the top rail foam (G). Stick the foam to the bottom of the top rail (I) with matching the holes of both parts. • Fix the top rail (I) and the side brackets (F) from the inner of the cabinet by using 10 screws (S).
  • Page 17 NOTICE The accordion shutters are marked LEFT (D) and RIGHT (E) for easy identification. • Slide the rail of the right accordion shutter (E) out of the frame. • Slide the rail into the side brackets (F) at the main unit. •...
  • Page 18: Installation (In Window)

    • Repeat on the other side with the left accordion shutter (D). Step 3: • Fix the accordion shutter by using 2 screws and washers (Q). Do not tighten too firmly as later they will be loosened again. Installation (in Window) •...
  • Page 19 Installation (Wooden Window) • Place the cabinet centered on the window sill. The bottom rail needs to be placed against the window sill’s offset. • Close the window against the top rail (I). • Fix the cabinet with 2 screws (P). NOTICE We recommend to pre-drill the holes prior screwing in the screws.
  • Page 20 Installation (Vinyl -Clad Window) • Place 2 safety locks (R) into the holes located in the bottom of the cabinet and fix them with 2 screws and nuts (T). • Shift cabinet left or right as needed to line up the center of the cabinet on the center line marked on the inner sill.
  • Page 21 Step 2: • Hold each support bracket (L) flush against the outside of the sill, and tight to the bottom of the cabinet. Mark the brackets at the top level of the sill and remove them again. Step 3: • Assemble the sill bracket (M) to the support bracket (L) at the marked position by using the flat head screw and nut (N).
  • Page 22 Step 4: • Fix both support brackets (L) to the cabinet by using the screws and nuts (O). Step 5: 1 1/4" - 1 1/8 " (32 – 41 mm) • The cabinet must be tilted at the back, to ensure a proper drain of condensation water or rain water.
  • Page 23 Installation (Extend Accordion Shutter) Step 1: • Carefully open the window to get access to the fixing screws. • Loosen the fixing screws (Q) of the accordion shutters (D,E). • Extend the accordion shutter to the window frame. • Not shown: Use the strips of the weather stripping (C) to close any leaking points.
  • Page 24 Installation (Fixing and Sealing the Window) Step 1 NOTICE Before securing the lower window sash, mark and drill 2 pilot holes to prevent it from splitting. • Secure the position of the lower window sash using the bracket (J) and 2 screws (P). Step 2 •...
  • Page 25 Step 3 • Place the sash seal (B) between the lower and upper window sash. Installation (Reinstalling the Main Unit) Step 1: • Carefully insert the main unit into the cabinet.
  • Page 26 Step 2: • Connect the front panel with the main unit. Step 3: • Attach the front panel to the main unit.
  • Page 27 Step 4: • Fix the front panel to the main unit with the 4 screws being removed at the beginning of the disassembly. Step 5: • Put the filter back to the main unit.
  • Page 28 Step 6: • Close the front cover. Step 7: • Measure the widths between the isolation board ledge of the accordion shutters (B) and (C). • Cut the isolation boards (N) according to the measured widths.
  • Page 29: Operation

    Step 8: • Slide the Insulation boards (N) into the allotted gap molded at the accordion shutters (D, E) Operation Performance test DANGER Risk of electric shock! The power plug of this product provides LCDI protection (Leakage Current Detection and Interruption). If the LCDI is de-activated this indicates an arcing fault.
  • Page 30 NOTICE If the indicator on the power plug (6) does not light up, consult a specialist before using the product. Installing/replacing the batteries NOTICE The batteries are not provided. Use 2 x 1.5 V type AAA/LR03 batteries. Switching on/off To switch on/off the product, press the on/off button (19) either on the remote control or on the control panel.
  • Page 31 Icon Icon Description control panel remote control Auto: Depending on the selected mode, the set temperature and the room temperature, the product automatically sets the fan speed. Low airflow Medium airflow High High airflow Temperature control NOTICE The temperature control does not work in fan mode. Set the target temperature with the decrease (13) and increase (12)
  • Page 32 Sleep function NOTICE The sleep function works only when the product is set to cooling or auto mode. – The sleep function increases the target temperature by 2 °F (1 °C) 30 minutes after activation. – After another 30 minutes the target temperature is increased by another 2 °F (1 °C).
  • Page 33 – The remote control transmits the measured temperature in 3-minute intervals to the main unit. – This allows to set the target temperature for a specific location in the room. NOTICE When the main unit does not receive any signal from the remote control for 7 minutes, it switches off the follow me function.
  • Page 34 LEDs on/off • Press the LED button (28) to switch off/on the lights of the control panel (1). NOTICE The LEDs light up for a short time when a setting is changed. Reset NOTICE The reset function is only available for the remote control. •...
  • Page 35 Fresh air vent control • Change the position of the fresh air vent control (2) to choose one of the below air circulation mode. Position Description Vent Exhaust Vent closed: The air Closed Closed circulates inside the room. Half opened: The fresh air is drawn into the room from Open Closed...
  • Page 36: Cleaning And Maintenance

    Cleaning and Maintenance WARNING Risk of electric shock! To prevent electric shock, unplug the product before cleaning. WARNING Risk of electric shock! During cleaning do not immerse the product in water or other liquids. Never hold the product under running water. Cleaning the removable air filter •...
  • Page 37: Troubleshooting

    • Open the front cover and remove the filter. • Pull out the -filter on the right side. • Rinse the filter thoroughly in warm water with mild detergent. • Gently shake off the excess water from the filter and air-dry it. •...
  • Page 38 Problem Solution • Clean the removable air filter. • Check the air vents for obstructions. • Adjust the airflow direction. The product does not cool • Ensure the doors and windows are efficiently. closed. • Compressor has shut off due to changed operating mode.
  • Page 39: Fcc - Supplier's Declaration Of Conformity

    Electric heating sensor error. Condenser temperature sensor error. Outside temperature sensor error. Unit malfunction. FCC – Supplier’s Declaration of Conformity B07Y2BTPJ3 Window-Mounted Air Conditioner with Remote - Cools 1500 Square Feet, 25000 BTU, Energystar Unique Identifier B07Y2B738L Window-Mounted Air Conditioner with Remote - Cools 1000...
  • Page 40: Specifications

    Consult the dealer or an experienced radio / TV technician for help. Canada IC Notice This Class B digital apparatus complies with Canadian CAN ICES-3(B) / NMB-3(B) standard. Specifications B07Y2BTPJ3 Model number 22020310001375 Voltage/frequency: 208 / 230V, 1 Phase, 60 Hz Rated input: 2427 W / 2398 W (max.
  • Page 41 Operating temperature indoor: 62-90 °F (17-32 °C) Operating temperature 64-109 °F (18-43 °C) outdoor: Dimensions approx. 26.5 x 18.6 x 26.5" (W x H x D): (67.3 x 47.3 x 67.4 cm) Net weight: approx. 136.2 lbs (61.8 kg) Refrigerant type + quantity: R410A, 35.98 oz (1.02 kg) Remote control range: 26 ft (8 m)
  • Page 42 Feedback and Help Love it? Hate it? Let us know with a customer review. AmazonCommercials is committed to delivering customer-driven products that live up to your high standards. We encourage you to write a review sharing your experiences with the product. amazon.com/review/review‑your‑purchases# amazon.com/gp/help/customer/contact‑us...
  • Page 43 amazon.com/AmazonCommercial MADE IN CHINA FABRIQUÉ EN CHINE HECHO EN CHINA V05-11/19...

This manual is also suitable for:

B07y2b738l

Table of Contents