4. Description of functions

The dimmer is equipped with a rotary switch with 10 posi-
tions in order to set the operating mode:
Rotary switch for setting 10 func-
tions
Potentiometer for setting the dim-
ming time from 1 s to 60 min (for
wake-up and snooze function, stair-
case time switch and switch function)
ON = Dimmer is always on
Functions for dimmable compact fluorescent
lamp (CFL) (ESL)
Position 1
With automatic load detection (usually trailing edge),
always start with 100% to ignite the CFL
Dimming down only possible after 3 sec.
Position 2
No automatic load detection (always with leading edge)
Always start with at least 50% to ignite the CFL
Dimming down only possible after 2 sec.
A1
A2
B1
N
LS 3
L
N
L
Position 3 Prog
Teach in light settings and minimum brightness (only for CFL)
L With several compact fluorescent lamps, an annoying
flickering may occur when dimming in position 1.
In this case, use position 2.
Carry out settings only with warm compact fluorescent
lamps (after approx. 5 minutes).
L Several compact fluorescent lamps may cause an overload
in position 2 that automatically leads to the load dimming.
A1
A2
Select position 1 in order to avoid this
Function for LEDs
DIMAX 532
Position 4: LED 2
No automatic load detection (always with leading edge) (ideal
for dimming problems with LEDs)
L Several LED types may cause an overload in position 4
2
that automatically leads to the load dimming.
perm
ON
Select position 6 or 7 in order to avoid this
1
LED1
Functions for standard lamps (e.g., bulbs, halogen
lamps, transformer, LEDs)
N
L
Position 5 Prog
Teach in light settings and minimum brightness
Position 6 Comf
Comfort function
With automatic load detection for the conventional lamp
types
Position 7 Strd
Standard function
With automatic load detection for the conventional lamp
types
Position 8
2-push button function using diode module with double
switch or rocker button
Position 9
Staircase time switch function
Position 10
Switch function (e.g., for presence and motion detector)

5. Setting the functions

1. Wake-up function (comfort function)
active in position 1, 2, 4, 6, 10
The dimmer dims from the minimum brightness up to the
switch-on brightness taught-in within the set dimming time
(activation via double click).