Download Print this page

Patriot PCO MAG Installation Manual

Advertisement

Quick Links

PATRIOT PCO MAG
Installation Guide
The PCO MAG is installed in the ductwork of
the central air system to reduce odors and
airborne biological contaminants for improved
indoor air quality. The PCO MAG also reduces
microbial growth within the air system.
PROTECT EYES FROM UV LIGHT
TURN OFF UNIT OR DISCONNECT
BEFORE SERVICING
• Only qualified technicians should install this product
• Install in accordance with relevant building codes
• Read instructions carefully including safety warnings
*Installation of this product by anyone other than licensed HVAC or electrical contractors voids warranty.
© 2016 Patriot UV - Manufactured by Triatomic Environmental, Inc.
1
Parts List
PCO MAG Unit
A
B
PCO MAG 11 UV Lamp 1 Year*
PCO MAG 11 UV Lamp 2 Year*
C
D
PCO MAG 15 UV Lamp 1 Year*
PCO MAG 15 UV Lamp 2 Year*
E
F
ER Power Supply*
B
ST/DT Power Supply*
G
C
H
SI/DI Power Supply*
Self-tapping Screws
I
D
J
Quick Nut (plastic)
Spade Connector
K
E
L
Tap-in Connector
"Z" Mounting Bracket
M
*Note: only one lamp and power supply are included with PCO MAG.
N
Sight Glass
Warning Sticker
O
D
TUVL-115P
E
TUVL-215P
Note: These parts are only included
with PCO MAG Dual.
5
Connecting to Power
IMPORTANT
Before connecting to power confirm which PCO MAG model is being installed. Turn off main
power source before installation. Model information is printed on the Power Unit cover.
IMPORTANT! Must be wired to constant power - do not connect to blower relay.
4 PIN
CONNECTOR
PCOMAG ER
BLACK
COMMON / BLUE
HOT / RED
24 VAC TRANSFORMER
4 PIN
CONNECTOR
PCOMAG
SI/DI
L1 - BLACK
ST/DT
L2 or N - WHITE
GND - GREEN
6
UV Lamp Connection
Make sure the flanges are aligned and then push
the connectors firmly together. A tight connection
ensures a proper water-resistant seal.
Align Flanges
1.
US patent #7,704,463
WARNING
IMPORTANT!
PAT-PCO-MAG-MAN 12.5.16
F
A
G
H
WARNING
M
N
UV LAMP
24 VAC
RED
POWER SUPPLY
UV LAMP
120-277 VAC
POWER SUPPLY
Optional 2nd UV Lamp
2.
Typical installations include:
PCO MAG single in air handler
A
PCO MAG dual in air handler
B
PCO MAG in Package Unit
C
2
Installation Notes
The PCO MAG is usually installed inside the central
air handling system. The unit should be oriented so
that the air flows past the UV Light first then into
the Matrix Element but a reversed installation is
permitted if mounting on the return-side of the coil.
If a second optional UV lamp is used (PCO MAG
Dual) select a location inside the air system that
will allow it to shine on the greatest surface area or
the area with the most evident microbial growth.
To install the secondary UV light use the Optional
2nd Remote UV Light Installation Instructions
provided with PCO MAG Dual.
I
J
K
4
Air Handler Interior
L
Surface Installation
1.
Determine the optimal position for
placement of PCO MAG inside the air
system.
2.
Use a utility knife to cut a slit in the
insulation on the interior surface.
WARNING
3.
Place the magnetic mounting bracket
directly on the metal surface or remove the
O
magnet and hard-mount the bracket using
the self-tapping screws provided. Use foil
tape to close the cut in the insulation.
Systems with high 24 VAC loads may require the installation of a separate 24 VAC
transformer to power the UV light.
Always use a separate 24 VAC transformer with "communicating" air systems and all
Patriot PCO Dual (PAT-PCO-DER) models.
Draws 16 VA, may need to do load calculation: Volts under load X Amps under load.
7
Lamp Replacement
The germicidal UV lamp in Patriot PCO needs to be
replaced periodically. TUVL-111P and TUVL115P lamps
should be replaced every year. TUVL-211P and TUVL-215P
should be replaced every 2 years.
Note: UV lamps will continue to emit visible light but lose
germicidal effectiveness over time. You can upgrade to a 2
year lamp with your existing Patriot PCO system.
CAUTION!
UV lamps contain small amounts of mercury - dispose of lamps in accordance with
local environmental regulations. For more information visit www.lamprecycle.org
Note: Use of replacement UV lamps other than Patriot UV voids warranty.
A
Package Unit
C
3
Mount Lamp
Mount the UV Lamp to the PCO
MAG unit as shown using 2 quick
nuts
.
J
J
Important! do not install the mounting
magnet within 12" of digital signal
devices as this may cause interference .
IMPORTANT!
Replacement lamps for
B
C
Replacement lamps for
D
E
Air Handler
B
2nd UV Lamp
2.
3.
PAT-PCO-MAG11
TUVL-111P
TUVL-211P
PAT-PCO-MAG15
TUVL-115P
TUVL-215P

Advertisement

loading

Summary of Contents for Patriot PCO MAG

  • Page 1 IMPORTANT transformer to power the UV light. Before connecting to power confirm which PCO MAG model is being installed. Turn off main power source before installation. Model information is printed on the Power Unit cover. Always use a separate 24 VAC transformer with “communicating” air systems and all Patriot PCO Dual (PAT-PCO-DER) models.
  • Page 2 Remote UV Light. Simply connect the lamp lead to the Power Supply replacement sticker. power cable on the left side of the Patriot PCO Power Unit. 2. Drill a ½” hole through the orange circle To add a second UV light to an existing Patriot PCO system on the sticker.