LaGard SMARTLINC Setup Instructions

Multiple lock system

Advertisement

Quick Links

AUthorised dealer:
AVAILABLE FEATURES
MASTER CODE
(Factory set to 1-2-3-4-5-6-7-8)
Change
Code
Enroll/Delete
Locks
Install/Delete
Manager
Lock Options
Set
Reprogram
Software
Access
to Master Menu
Download
Audit
Time Lock Periods
Set
MANAGER CODE
(Factory set to 1-1-1-1-1-1)
Manages
Users
Change
Time Delay Values
Download
Audit
Control
Temporary Time Lock
Extend
Open Period, if enabled
USER CODE
to nine users per lock, including Manager
Up
Lock
Open
Change
Code
Immediate Lock
Set
MULTIPLE LOCKS
to Five
Up
APB (Auxiliary Power Box)
be ordered with every system no matter how many locks
Must
enrolled
are
Provides
constant power to audit information in the event of primary
(battery
or A/C) power loss
eKEY
MODE
II
Available
on each lock, if enabled
Available
for Manager and Users only
© copyright 2005
SMARTLINC
Multiple Lock System
logic module & set-up instructions
Optional eKey
P/N 40169
(P/N)12-249 v2 • 9/08
TIME DELAY
Programmable
Period: 1 - 99 minutes
Delay
Period: 1 - 19 minutes
Open
Counting mode selectable (up, down or invisible)
Delay
Time Delays Can Run At Once
Two
TIME DELAY OVERRIDE
to override time delay
Ability
Assigned
to User #9, if enabled
SILENT SIGNAL ALARM
II
Programmable
Unavailable
on a single lock system using AC Power
REMOTE DISABLE
Programmable
Unavailable
on a single lock system using AC Power
AUDIT
lock will record the last 500 operations with time, date, user
Each
and the activity
DUAL CODE
Programmable
set up, automatically installs User #2 (Default User
If
2-2-2-2-2-2)
Code
Codes required to open and access Manager Menu
Two
WRONG TRY PENALTY
(4) consecutive invalid codes initiates
Four
LOW BATTERY WARNING
Repeated
audio and visual signal (LCD readout and repeated
beeping)
during opening indicates battery low
AUDIO AND VISUAL SIGNAL
Double
signal (LCD readout and unit beeps) indicates entry is valid
accepted
or
signal indicates invalid or not accepted
Triple
TIME LOCK
Time Lock periods are available for set-up
Two
Selectable
for each lock - Time Lock 1, Time Lock 2 or No
Lock
Time
Standard
Week (4 open periods per day)
Special
Events (up to 20 close periods programmable with day and
month
- i.e., January 1, July 4)
Immediate
Time Lock (until next available open period)
Temporary
Time Lock (to required date and time, maximum of four
weeks)
(4)
Lock Open Period Extension (Maximum two (2) hours),
Time
enabled
if
Daylight
Saving Time
SYSTEM RECOMMENDATION
is recommended to run the SMARTLINC
It
laptop
running Windows® 2000 or higher.
sales@safeguardgroup.com.au
www.safeguardsafes.com.au
on each lock
(Optional Alarm Box Required)
on each lock
(Optional Alarm Box Required)
on each lock
on each lock
software on a PC or
T: 1300 764 971
delay period
Kaba Mas LLC
page 1 of 8

Advertisement

loading
Need help?

Need help?

Do you have a question about the SMARTLINC and is the answer not in the manual?

Questions and answers

Summary of Contents for LaGard SMARTLINC

  • Page 1 SYSTEM RECOMMENDATION • Available for Manager and Users only • is recommended to run the SMARTLINC software on a PC or laptop running Windows® 2000 or higher. © copyright 2005 (P/N)12-249 v2 • 9/08 Kaba Mas LLC...
  • Page 2 Using either Windows Explorer or the START button, find the LA GARD folder on the hard drive. Within the LA GARD folder there are 3 folders labeled DSTUpdate, SMARTLINC and Total Audit. Open the SMARTLINC folder and double click on the file named SMARTLINCSETUP (see Screen 1).
  • Page 3 Eveready batteries is recommended (see Figure 1). 2. Plug Interface and cable into PC and open SMARTLINC Set-up Software. 3. Plug the 43098 cable into the lock through the port on the lock marked ENT. 4. Select the lock ID for the lock to be programmed. It is a good idea to mark the lock itself with its ID number.
  • Page 4 CONTROL UNIT (LOGIC MODULE) SET-UP To set up the logic module, click on the Control Unit Set-up button on the opening screen (see Screen 8). A window with the default configuration will appear (see screen 9). In this window select the features to be enabled on the Logic Module. •...
  • Page 5 Eveready batteries are recommended. 2. Plug Interface and cable into PC and open SMARTLINC Set-up Software. 3. Connect the 43097 cable to the Logic Module through the port on the keypad. 4. Press the Send button on the software (see Screen 12).
  • Page 6 2. Plug Interface and cable into PC and then connect the 43097 cable to the Logic Module through the port on the keypad. 3. Press any key to power up SMARTLINC. • Display will show either “ENTER COMBO” or SELECT LOCK” when two or more locks are installed.
  • Page 7 Eveready batteries are recommended. 2. Plug Interface and cable into PC and open SMARTLINC Set-up software. 3. Connect the 43097 cable to the Logic Module through the port on the keypad. 4. Open the correct file for the Time Lock period (1 or 2) that will be downloaded to this lock.
  • Page 8: Troubleshooting

    • A communication error (check cable and battery connections and/or re-start Set-up application) • Check COM port setting. Try selecting a different COM port and retry. • SMARTLINC is not in PC-Link mode (Activate PC Link in Master menu) © copyright 2005 (P/N)12-249 v2 •...