LaGrand AUDITGARD Programming Instruction

Advertisement

Quick Links

LOCKS
4300
Dual-Handed
Swingbolt
6040-DB
Deadbolt
STANDARD FEATURES
MANAGER CoMbINATIoN (Factory set to 1-2-3-4-5-6 or 7-8-9
depending on combination length)
WRoNG TRY PENALTY
• Four (4) consecutive invalid combinations initiates five (5) minute
delay period.
LoW bATTERY WARNING
• Repeated LED flashing and repeated beeping during opening
indicates battery is low and needs immediate replacement.
AUDIo AND VISUAL SIGNAL
• Double signal - two (2) LED flashes and two (2) beeps - indicates
entry is valid or accepted.
• Triple signal - three (3) LED flashes and three (3) beeps - indicates
invalid or not accepted.
AUDIT TRAIL
512 Audits with User ID, timestamp and operation
• For audit features see LG-AUDIT Software Package
CoMbINATIoN LENGTH
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
• Open Lock
USER CoMbINATIoN
• Open Lock
• Change Combination
TIME DELAY
• Delay period 1 - 99 minutes
• Open period 1 - 19 minutes
DUAL MoDE
• Two combinations required to open
SIGNAL To DISAbLE LoCK oPENING (Alarm Box Required)
• Input signal disables opening of lock by valid combination
PC PRoGRAMMAbLE FEATURES
MULTIPLE USERS (Up to nine - 1 Manager and 8 Users)
User # Installed
2
3
£ £ ££ £ £ £ £
TIME DELAY oVERRIDE
• Ability to add second combination to override delay period
SILENT SIGNAL ALARM (Alarm Box Required)
• Duress signal if last number of combination(s) is entered using
one number higher or one number lower.
SIGNAL To DISAbLE LoCK (Alarm Box Required)
• Input signal disables opening with valid combination OR
• Input signal disables all lock functions.
© copyright 2006-2008
MANAGER PROGRAMMING
SUGGESTED KEYPADS
3750-K
Round Entry
3125
Round Entry
3190 Privat
(Optional)
4
5
6
7
8
9
(P/N)759.128 Rev A • 12/08
AUDITGARD
66E Firmware
4300 Dual-Handed Swingbolt
6040-DB Deadbolt Lock Instructions
• All locks are shipped from the factory in Pre Set-up mode, with
no features installed.
• Lock will open when 1 is pressed.
• Please follow LG-AUDIT PC software instructions to initially
configure locks to default settings.
MANAGER CoMbINATIoN MUST bE CHANGED PRIoR To
PERFoRMING ANY ACTIoN oTHER THAN oPENING THE LoCK
oPENING THE LoCK (Without eKEY or eKEY
1. Enter valid combination.
II
2. The unit will indicate a valid combination entry with a double signal.
3. Within four (4) seconds, turn the keypad to the open position
ACTIVE
(clock-wise) if using a dead bolt style lock, or turn the handle to the
open position if using a swing bolt style lock.
4. Pull door open.
• Invalid Combination Entry - Unit will signal three (3) times.
CHANGING YoUR CoMbINATIoN (Without eKEY or eKEY
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
If your unit is programmed for Dual Combination, each combination
must be changed independently.
1. Enter existing combination and hold down the last digit until unit
double signals and the LED stays on.
2. Press the "0" key.
3. Enter your NEW combination two times.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
Note: Test unit operation several times before closing the door.
CAUTION: When selecting a combination do not use
birthday or other predictable data that could give
correlation between the user and combination. Keep the
combination secret.
• Valid Combination Entry - Double signal after valid combination
is entered.
• Invalid Combination Entry - Triple signal indicates the old
combination is still valid.
ACTIVATING USER (Manager Only, without eKEY or eKEY
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
2. PRESS 1. Unit signals twice.
£
3. Press User number, 2 to 9.Unit signals twice.
4. Enter NEW User combination two times.
5. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Combination Entry - Double signal after valid combination
is entered.
• Invalid Combination Entry - Triple signal indicates the old
combination is still valid.
DISAbLE USER (Manager Only, without eKEY or eKEY
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
£
1. Enter Manager combination and hold down last digit of
combination until unit double signals and the LED stays on.
£
2. PRESS 2. Unit signals twice.
3. Press User number, 2 to 9. Unit signals once.
4. User is temporarily disabled. (User combination is saved and will
be valid if reinstated.)
£
5. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
£
)
II
)
II
)
II
)
II
Kaba Mas LLC
page 1 of 4

Advertisement

loading

Summary of Contents for LaGrand AUDITGARD

  • Page 1 AUDITGARD 66E Firmware 4300 Dual-Handed Swingbolt 6040-DB Deadbolt Lock Instructions MANAGER PROGRAMMING LOCKS SUGGESTED KEYPADS • All locks are shipped from the factory in Pre Set-up mode, with no features installed. 4300 3750-K Dual-Handed • Lock will open when 1 is pressed.
  • Page 2 REINSTATE USER (Manager Only, without eKEY or eKEY ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter Manager combination and hold down last digit of combination until unit double signals and the LED stays on. 2. PRESS 1. Unit signals twice. 3.
  • Page 3 oPENING THE LoCK (With eKEY or eKEY 1. Enter valid combination and insert and remove key. 2. The unit will indicate a valid combination and key entry with a double signal. 3. Within four (4) seconds, turn the keypad to the open position (clock-wise) if using a dead bolt style lock, or turn the handle to the open position if using a swing bolt style lock.
  • Page 4 CHECK USER STATUS (Manager Only, with eKEY or eKEYII) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter Manager combination and hold in key until unit double signals and the LED stays on. 2. Remove key. 3. PRESS AND HOLD DOWN 1. Unit signals twice. 4.

This manual is also suitable for:

43006040-db3750-k31253190 privat