blink) press "OK" or "t" / "s" to adjust the number
("t" to reduce, "s" to increase). Press "OK" to
confirm and continue to adjust the nest number. After
confirming the 4 number, the set is finished and LCD
show back to function.
The threshold value is 2200W. If the threshold is set
over 2200W, LCD will display "Err1" for 3 seconds
and return to the setting mode again. This function is
mainly use to prompt peak load.
6. Reset the total using time
Press "t" / "s" button to show "total using time", hold
"SET" button for 2 seconds to enter restting mode (the
number on LCD will blink). Press "OK" button to reset the
time and LCD show back to "total using time".
7. Reset the energy
Press "t" / "s" button to show "total used energy", hold
"SET" button for 2 seconds to enter restting mode (the
number on LCD will blink). Press "OK" button to reset the
energy and Co
LCD show back to "total used energy".
2
8. Description for LCD and symbol
Code
Data Format
Unit
01
XXXX.xx
W
02
X.XXx
-
03
XXXxx
mA
04
XXX.xx
V
05
XX.xx
H z
06
XXXXxx
Min
07
XXXX.xx
kWh
08
XXXX.xx
Kg
5
Appendix
Display on LCD
7
Data Name
Power
Power Factor (PG08 only)
Current
Voltage
Frequency
Total Usage Time
Total Used Energy
Co
2
(PG08 only)
9. Specifications
Functions
Input Range
RMS Voltage
195 ~ 265 Vrms
RMS Current
2.5 ~ 10 Arms
Active Power
0.2 ~ 1 W
1 ~ 5 W
5 ~ 2200 W
Power Factor
For : 0.2 ~ 5 W
(PG08 only)
For : 5 ~ 10 W
For : 10 ~ 2200 W
Active Energy
For : 5 ~ 2200 W
Energy Usage
Minutes
Time
Applications
Teaching, Demonstration & Testing of
Electrical Energy Saving of Household &
Office Appliances. It can be used in
Houses, Offices, Shops, Schools,
Laboratories etc.
10. Transportation and Storage
The product must be protected from radical impacting in
transporting and unpacking, and transporting and storing
according
to
GB/T15464-1995
specification for the packaging of instrumentation products).
The product must be stored and kept on the trestle table with
original package, and stack-height must be less than 8 layers.
Keep the room clean. The temperature must be 0 to 45
relative humidity must be less than 85%, and make sure that
there are no corrosive materials in the air.
CERTIFICATE OF CALIBRATION
We hereby certify that this product has been calibrated
and found to be in accordance with the applicable
SPECIFICATIONS and MECO STANDARDS.
Accuracies of the standard equipment used in this
calibration are traceable to the National Standards.
MECO METERS PVT. LTD.
Plot No. EL-60, MIDC Electronic Zone,
TTC Industrial Area, Mahape,
Navi Mumbai - 400710 (INDIA)
Tel : 0091-22-27673311-16, 27673300 (Board)
Fax : 0091-22-27673310, 27673330
E-mail : sales@mecoinst.com
Web : www.mecoinst.com
SR. NO.
:
CHECKED BY :
DATE
:
MODEL NO.
:
PG07-08 : 24-10-2012
Accuracy Class
0.5
1
<10
5
1
>0.03 PF
<0.03 PF
<0.01 PF
1
-
(General-purpose
®
SINCE 1962
0
C,
6
8