  • Page 3 Lighthouse Worldwide Solutions REMOTE 2010/3010/5010/5100 Airborne Particle Counter Operating Manual...
  • Page 4 Copyright © 2010 by Lighthouse Worldwide Solutions. All rights reserved. No part of this document may be reproduced by any means except as permitted in writing by Lighthouse Worldwide Solutions. The information contained herein constitutes valuable trade secrets of Lighthouse Worldwide Solutions.
  • Page 5 EU DECLARATION OF CONFORMITY Manufacturer’s Name Lighthouse Worldwide Solutions, Inc. Manufacturer’s Address: Lighthouse Worldwide Solutions, Inc. 1221 Disk Drive Medford, OR 97501 Declares that the product: Product Name: Remote Airborne Particle Counter Model Number(s): REMOTE 2010/3010/5010/5100 Conforms to the following Product Specifications:...
  • Page 7: Table Of Contents

    Table of Contents About this Manual Text Conventions ........................ i Additional Help ........................i Chapter 1 General Safety Safety Considerations ....................1-1 Laser Safety Information ....................1-1 Electrostatic Safety Information ..................1-2 Chapter 2 Introduction Overview ........................2-1 Description ........................2-1 Accessories ........................
  • Page 8 Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual Safety ..........................5-1 Maintenance ........................5-1 Calibration ......................5-1 Purge Count Test ......................5-1 Fault Isolation ........................ 5-2 Appendix A Limited Warranty Limitation Of Warranties: ..................... A-1 Warranty Of Repairs After Initial Two (2) Year Warranty: ......... A-1...
  • Page 9: About This Manual

    About this Manual This manual describes the detailed operation and use of the Lighthouse Remote 2010, 3010, 5010 and 5100 Airborne Particle Counters. Text The following typefaces have the following meanings: Conventions italics Represents information not to be typed or interpreted literally. For example, file represents a file name.
  • Page 10 Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual 248083200-1 Rev 5...
  • Page 11: Chapter 1 General Safety

    General Safety Safety Warnings and cautions are used throughout this manual. Familiarize Considerations yourself with the meaning of a warning before operating the particle sensor. All warnings will appear in the left margin of the page next to the subject or step to which it applies. Take extreme care when doing any procedures preceded by or containing a warning.
  • Page 12: Electrostatic Safety Information

    Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual Electrostatic Safety Information WARNING: Electrostatic discharge (ESD) can damage or destroy electronic Using a wrist-strap without an components. Therefore, all service or maintenance work should be isolation resistor will done at a static-safe work station. A static-safe work station can be...
  • Page 13: Chapter 2 Introduction

    Introduction Overview This operating guide introduces you to the Lighthouse REMOTE 2010/ 3010/5010/5100 Airborne Particle Counter family. Also included in this guide are instructions for inspecting, using, and maintaining the instrument. Any changes of instrument operation due to design changes are covered at the back of this guide.
  • Page 14: Accessories

    Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual The REMOTE 2010/3010/5010/5100 line of Airborne Particle counters was created for continuous operation 24 hours per day, 7 days per week. Using an external vacuum source, the instrument provides versatile mounting options and can be installed where space is at a premium.
  • Page 15: Calibration

    Introduction REMOTE 5100 1.0 CFM (28.3 LPM) Flow Rate 50% (per JIS) Counting Efficiency Laser Diode Laser Source Zero Count Level <1 count/5 minutes (per JIS) External Vacuum >18" (45.72 cm) of Hg Vacuum Requirements Calibration NIST Traceable Pulse Output Communication Modes Supporting Software Lighthouse Monitoring System...
  • Page 16 Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual 248083200-1 Rev 5...
  • Page 17: Chapter 3 Getting Started

    Getting Started Unpacking The instrument is thoroughly inspected and tested at the factory and is ready for use upon receipt. and Initial Inspection When received, inspect the shipping carton for damage. If the carton is damaged, notify the carrier and save the carton for carrier inspection. Inspect the unit for broken parts, scratches, dents, or other damage.
  • Page 18: Interpreting Indicators

    Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual Operation Interpreting Indicators Both front-panel indicators have a specific meaning when illuminated. The figure below shows location of the indicators and gives a brief description of their meaning. POWER lights up when power is CALIBRATE LED comes...
  • Page 19: Installation

    Getting Started Installation Your instrument(s) can be easily prepared for use by performing the steps below. Depending on the unit’s output, each instrument can be located up to 1000 feet (330 meters) from the counting device. 1. Locate instrument(s) in areas to be sampled. 2.
  • Page 20: Installing An Isokinetic Probe

    Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual 5. Connect cable fitted with a shielded RJ-45 plug at each end between the RJ-45 receptacle on the bottom of the instrument to the connector on the Sensor Interface Unit (SIU). Note: Figure 3-6 Connecting instrument to SIU The unit is pow- ered through the SIU.
  • Page 21: Data Connector Signals

    Technical Data Data The data output of the REMOTE Airborne Particle Counter is presented as a balanced line output in full compliance with Balanced Connector Voltage Interface Circuits standard EIA-422-A. According to these Signals standards, a "binary 1" signal of not less than one microsecond indicates a detected particle, and a "binary 0"...
  • Page 22 Lighthouse REMOTE 2010/3010/5010/5100 Airborne Manual By default, the sensors are set at the factory for a differential count output. Sensors can be ordered for a cumulative count, but this must be specified when the order is first made. 248083200-1 Rev 5...
  • Page 23: Chapter 5 Maintenance Procedures

    Procedures Introduction This chapter provides instructions for routine maintenance that may be required for your REMOTE 2010/3010/5010/3100/5100 instrument. The maintenance procedures described in this chapter are not required on regular or prescribed intervals and should be performed only if you have reason to question the data you are receiving from the instrument.
  • Page 24: Fault Isolation

    Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual Allow the instrument to take 6 samples. If an averzge of more than one count per five-minute period is reported, allow the instrument to sample for 30 minutes to purge it, then repeat the test.
  • Page 25: Appendix A Limited Warranty

    BILITY, OR PRODUCT LIABILITY CLAIM AND BUYER AGREES TO WAIVE SUCH CLAIMS. LWS’s SOLE AND EXCLUSIVE LIABILITY AND BUYERS SOLE AND Lighthouse Worldwide Solutions (LWS) warrants that all equip- EXCLUSIVE REMEDY, FOR ANY NONCONFORMITY OR ment shall be free from defects in material and workmanship...
  • Page 26 Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual 248083200-1 Rev 5...
  • Page 27: Index

    Index Interpreting indicators 3-2 Isokinetic Sampling Probe 2-2 Accessories 2-2 Isokinetic Sampling Probe 2-2 Laser Diode 2-1 Laser Source 2-3 Calibration 2-3 Channel Threshold 2-2 Collection Optics 2-1 Communication Modes 2-3 Operating Temp/RH 2-3 Connections 3-2 Operation Counting Efficiency 2-3 Interpreting indicators 3-2 Cumulative count 4-1 Cumulative to differential output 4-1...
  • Page 28 Lighthouse REMOTE 2010/3010/5010/5100 Operating Manual Technical Data Cumulative to differential output 4-1 Data connector signals 4-1 Troubleshooting, Zero Count 5-2 Warning Electrostatic Discharge 1-2 Hazardous Radiation Exposure 1-2 Infrared Radiation 1-1 Weight 2-3 Zero Count Check Troubleshooting 5-2 Zero Count Level 2-3...

This manual is also suitable for:

Remote 3010Remote 5010Remote 5100

Table of Contents