GeneReach cubee Mini-Centrifuge User Manual

GeneReach cubee Mini-Centrifuge User Manual

Advertisement

General Information

TM
The cubee
Mini-Centrifuge contains a rotor which is
driven by a motor and provides a centrifugal force to spin
down liquid samples in certain containers. It is supplied
with one rotor which suit for 1.5ml tubes, 0.5ml tubes and
0.2ml PCR strip tubes. It is designed for microfiltration, cell
separation and quick spin downs from the walls of tubes.
Please read this manual before operating the centrifuge.

Warranty

The centrifuge and rotor are covered by a one year
warranty. This warranty is void in the event of incorrect
operation, use of nonstandard spare parts of accessories
and unauthorized modification of the rotor or unauthorized
modification of the rotor or centrifuge. The rotor warranty
does not cover normal wear and tear or damage and/or
weakening caused by radioactive contamination, cleaning
agents. Fuses are not covered by the warranty.

Safety Precautions

NEVER
1.
Use the centrifuge in any manner not specified in these
instructions.
2.
Fill tubes while they are in the rotor.
3.
Put hands in the rotor area unless the rotor is
completely stopped.
4.
Move the centrifuge while the rotor is spinning.
5.
Use solvents or flammables near this or other electrical
equipment.
6.
Centrifuge flammable, explosive or corrosive materials.
Centrifuge hazardous materials outside of a hood.
7.
Caution
Do not attempt to open the lid or remove samples until the
unit has come to a complete stop. After the rotor has
stopped, the lid may be opened by grabbing it with the
thumb on the front and fingers on the back then lifting the
lid back on the hinge. Safe operation of the centrifuge
requires that the rotor be loaded in a balanced fashion.
Failure to load the rotor properly presents a hazardous
condition and may damage the centrifuge. Individual tubes,
strip tubes and/or adapters must always be loaded
symmetrically to ensure proper balance. Never run the
centrifuge with only one strip tube in place.

Specification

aqbd
Cat no.
Dimensions
183x151x153 mm
Speed
4700 rpm
Power supply
100-120V/200-240V, 50/60 Hz, AC
Fuse
2A, 250V
User manual for cubee
TM
Mini-Centrifuge

Operation

Before operating the centrifuge, be sure that the power
is switched on then simply close the lid of the centrifuge.
To stop spin down, press the lid. This will release the lid
lock and the rotor will slow down.

Cleaning

Before using any cleaning or decontamination methods
except those recommended by the manufacturer, check
with the manufacturer that the proposed method will not
damage the equipment. For cleaning, use a damp cloth
and a mild, noncorrosive detergent (pH<8). After
cleaning, ensure all parts are dried thoroughly before
attempting to operate the unit. Do not immerse the
centrifuge in liquid or pour liquids over it.
ALWAYS
1.
Load the rotor symmetrically.
2.
Locate the centrifuge within easy access to an
electrical outlet.
3.
Use only micro-centrifuge tubes made from plastic
and designed to withstand centrifugal forces of at
least 2000 x g.
Questions and Service
If you have a question about the centrifuge or require
service for the unit, please contact the dealer or call
numbers listed below. Do not send in a unit for service
without first calling to obtain a repair authorization
number and a decontamination form. Should the
centrifuge require service, be sure to decontaminate it
and enclose the decontamination form. The unit should
be properly packed to avoid damage. Any damage
resulting from improper packaging shall be the
responsibility of the user.
Manufacturer
GeneReach Biotechnology Corporation
nd
No. 19, Keyuan 2
Rd., Taiwan Central Science Park,
Taichung City 407, Taiwan
TEL:886-4-2463-9869 FAX:886-4-2463-8255
Email:sales@genereach.com
2012/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the cubee Mini-Centrifuge and is the answer not in the manual?

Questions and answers

Summary of Contents for GeneReach cubee Mini-Centrifuge

  • Page 1 Never run the responsibility of the user. centrifuge with only one strip tube in place. Specification Manufacturer aqbd Cat no. GeneReach Biotechnology Corporation Dimensions 183x151x153 mm No. 19, Keyuan 2 Rd., Taiwan Central Science Park, Speed 4700 rpm Taichung City 407, Taiwan TEL:886-4-2463-9869 FAX:886-4-2463-8255...
  • Page 2 在離心機完全停止運動之前,請不要翻開上蓋,或移 關於本產品如果您有任何問題,或需要零件服務,請 動轉子上的樣品。待轉子停止後,拇指在前,其餘手 聯繫當地的經銷商,或撥打下方的聯繫電話。請預先 指在後,將上蓋抓住,向後掀起。安全的使用方式要 電話溝通,並得到維修授權後,再將零件寄出。如果 求裝載樣品後轉子處於平衡的狀態。錯誤的裝載轉子 離心機需要維修,請先清潔離心機。零件需要進行適 將造成轉子損壞。樣品一定要對稱的方式放入轉子。 當的包裝,以免受到損傷。任何由於不正當包裝造成 當只有一個樣品時,請勿運轉離心機。 的機器損傷應由使用者承擔責任。 規格 製造商 型號 瑞基海洋生物科技股份有限公司 aqbd 外型尺寸 407 台中市西屯區中部科學園區科園二路 19 號 183x151x153 mm 馬達空載轉速 電話:04-2463-9869 傳真:04-2463-8255 4700 rpm 電壓 Email:sales@genereach.com 100-120/200-240V, AC 頻率 50/60 Hz 保險絲 2A, 250V 2012/07...

This manual is also suitable for:

Aqbd

Table of Contents