Power 13 kW, which is divided into three stages, 6 + 4 + 3 kW. range 30-85 °C. Power can be limited to 10, 9, 7, 6, 4 or 3 kW. EK 13 has a main switch, overheating protection, a thermostat, Simple connection operating indication, time delay and a fuse-protected outlet for a circulation pump.
The remainder will react with the and hardness values makes the water aggressive. metals in the system. This corrosion is often insignificant as the same volume of water circulates and it soon becomes oxygen-free. Värmebaronen EK 13...
Underfloor heating system Pressure drop diagram Freestanding heating unit With boiler EK 13 must be connected to: Open system: The expansion tank is connected in an unbroken, uninterruptible connection to the cartridge. The distance between the top of the highest radiator and the tank may not be less than 2.5 metres to...
When the load on the main fuses falls, the load guard reconnects the power disconnected in stages. Further information is available in the instructions for the VBB 12TX. To external control unit Värmebaronen EK 13...
26. LED, flashes when the two-hour lock is operating, normally off. 15. Indicator, power stage two. 27. Connection pin for power groups on immersion heater. 16. Indicator, power stage three. 17. Thermostat, power stages two and three. Värmebaronen EK 13...
Action in the event of electrical operation a while before the temperature in the system has been stabilised. When EK 13 is installed as a supplement to a boiler and the electric cartridge takes over the heating, any unnecessary air throughput Control panel and thus cooling of the boiler should be avoided.
1.16 q = water flow in m3/h P = cartridge's power output in kW. ∆t = temperature difference in °C. 1.16 = water's thermal absorption coefficient. To obtain the flow in litre/second, multiply q by 1/3.6 Värmebaronen EK 13...