SM- SM- SM- SM-295301 295301 295301 295301- - - - A A A A INSTRUCTION INSTRUCTION INSTRUCTION INSTRUCTION MANUAL MANUAL MANUAL MANUAL BLOCK BLOCK BLOCK BLOCK MANIFOLD MANIFOLD MANIFOLD MANIFOLD W4G2 W4G2 W4G2 W4G2- - - - SERIES SERIES SERIES SERIES SERIAL TRANSMISSION TYPE SERIAL TRANSMISSION TYPE...
Page 2
For For Safety Safety Use Use For For Safety Safety Use Use To use this product safety, basic knowledge of pneumatic equipment, including materials, piping, electrical system and mechanism is required (to the level pursuant to JIS B 8370 Pneumatic System Rules).
Page 3
INDEX MW4G※2-T8G※ Serial Transmission Type Manual No. SM-295301-A PRODUCT General outline of the system 3 Structure of the System 5 specifications 6 External dimensions of solenoid valve 10 Outside view of valve slave station 13 Indications and switches on slave station 14 Connection connector...
Page 4
1 PRODUCT PRODUCT 1. 1.1 General outline of the system 1) MW4G※2-T8G※ This solenoid valve system is equipped with a remote I/O station(NW4G※ 2-T8G ※ ), the CC-Link open field network system. (This is specified by CC-Link Partner Association. :hereafter referred to as CLPA) The following features are provided.
Page 5
1 PRODUCT Note: Before using this product, thoroughly red the User’s Manual. This document mainly describes MW4G※2-T8G※ and slave station(NW4G ※2-T8G※). For details about other units to be connected to the CC-Link, read relevant User’s Manual. Before operating this manifold solenoid valve, thoroughly read both this document and above manual to fully understand its functionality and performance.
Page 6
1 PRODUCT 1.2 Structure of the System This system chiefly consists of PLC body, Master unit, Solenoid valve MW4G※ 2-T8G※ and peripheral equipment. Combination of PLC and Master unit Type of CPU Type of Master unit AnN / AnA / AnU series AJ61BT11 AnS / A2US series A1SJ61BT11...
1 PRODUCT 1.3 Specifications 1) Specification of solenoid valve (1) Common specifications Model No. W4G2 Item Media Compressed air Valve configuration Pilot operation Applicable solenoid valve Soft spool valve 2 positions Minimum working pressure 3 positions Maximum working pressure MPa Proof pressure 1.05 Ambient temperature...
1 PRODUCT Specifications by model Item Single 2 positions Response time Double - 3 positions connection The response time shown in the table is with the supply pressure of 0.5 MPa and no lubrication. It changes depending on the supply pressure and the type of oil in the case of lubrication. Item Valve specifications Change –over position class...
Page 9
1 PRODUCT System Configuration including local station and intelligent device station Local station Local station Remote I/O Remote I/O Remote I/O Remote I/O Master station station station Intelligent Intelligent station device device Remote device station Remote device Remote device Remote device station station station...
Page 10
1 PRODUCT (2) Slave station specification Item T8G1 T8G2 T8G7 Power voltage (Unit side) DC21.6V~26.4V (DC24V ±10%) 60mA or lower (While all 100mA or lower (While all 70mA or lower (While all Electric consumption (Unit side) points are ON.) points are ON.) points are ON.) Power voltage (Valve side) DC22.8V~26.4V (DC24V +10%, -5%)
Page 11
1 PRODUCT 1.4 External dimensions of solenoid valve 1) Upper wiring type MW4GA2※0-T8G※ • Name of parts Input/Output block Electric component bloockT8G※ Masking plate Valve block Solenoid valve main body Supply /exhaust blocks End blocks R [SM-295301-A] -10-...
Page 12
1 PRODUCT 2) Side wiring type MW4GB2※0-T8G※ • Name of parts Input/output unit Electric componentT8G※ Masking plate Valve block Solenoid valve main body Supply /exhaust blocks End blocks R [SM-295301-A] ―11―...
Page 13
1 PRODUCT 3) Side wiring type MW4GZ2※0-T8G※ Name of parts Input/output unit Electric componentT8G※ Masking plate Valve block Solenoid valve main body Supply /exhaust blocks End blocks R [SM-295301-A] -12-...
Page 14
1 PRODUCT 1.5 Outside view of valve slave station 25.5 ① Monitor lamp The monitor lamp LED indicates the status of the slave station main body and network. ② Setting switches These switches are used to set a station No., transmission speed, and an output of the slave station when the communication error occurs.
Page 15
1 PRODUCT 1.6 Indicators and switches on Slave station 1) Monitor lamp Various LED lamps are installed in front of station to aid visual verification of operational conditions. Each function is printed on the sheet made of resin. Make use of them during maintenance works or for verification of operation. Name of LED Content of indication Lit when unit power is ON.
Page 16
1 PRODUCT station number, never touch internal circuit printed board. [SM-295301-A] ―15―...
Page 17
1 PRODUCT 1.7 connection connector The wiring of this slave station is performed using the water-proof connector as shown in the Fig. Communication connector (OUT) Power supply connector (M12 connector) Communication connector (IN) FG terminal Symbol Function Objects to be connected Connect to the master station, other remote I・O station, Communication IN / OUT...
Page 18
2 CAUTION 2. CAUTION Refer to User’s manual for the master station concerning to transmission delay • time. The transmission delay within the entire system depends on the scan time achieved by the PLC unit and on other devices included in the network. •...
3 OPERATION 3. OPERATION 3.1 Switch setting The switches are used for different kinds of setup: setting the station number, setting the transfer rate, specifying whether to hold or clear the output during an error. Since different switches are used for different kinds of setup, you must correctly identify the switch to be used.
Page 20
3 OPERATION The transfer rate should be set in the same manner as with all master stations, local stations and ! CAUTION: CAUTION: CAUTION: CAUTION: remote stations on the network. If this setting differs even in one station, no normal data link is possible.
Page 21
3 OPERATION 3.2 Correspondence between slave station input/output No. and PLC address No. 1) PLC address correspondence table This table shows the correspondence assuming that the serial transmission slave station is set at station No.1. Buffer memory address of the master station Exclusive output type 160H 161H...
Page 22
3 OPERATION How to count the number of manifold stations. ・The solenoid valve manifold station Input/output block Slave station Valve block No. is set sequentially from the left with the piping port put on the front regardless wiring block position. ・...
Page 23
3 OPERATION 3.3 Programming This slave station unit is seen as a 16-point output unit…T8G1, 32-points output unit …T8G2, 16-points input/16-points output unit …T8G7constituting a remote I/O station. (The unit monopolizes the position of a single station.) When creating programs, refer to the Mitsubishi User’s Manual (CC-Link system master/local units).
4 INSTALLATION 4. INSTALLATION 4.1 Installation When installing a solenoid valve unit, never attempt to hold it ! WARNING WARNING : : : : WARNING WARNING in position by means of the pipes connected to it. • Mount the solenoid valve by applying the mounting screws and/or mounting plate to the solenoid valve.
Page 25
4.1.3 In case of installing by means of DIN rail For W4G2 Series, you can change the manifold of direct mounting type to DIN rail mounting type. If not counted properly, dropping down of the manifold or damage to it may be caused, to which please pay your careful attention.
Page 26
4 INSTALLATION 4.2 Wiring It is required to connect signal circuit with power line to make this model MW4G※ 2-T8G※ function. Erroneous connection cases not only malfunction but in some cases, vital transmission damage to this station including other related devices. Read and understand the content of each User’s manual for Sequencer and CC-Link system, product of Mitsubishi Denki Co., Ltd ., as well as reading this manual to accomplish correct wiring.
Page 27
4 INSTALLATION 2) Wiring of Communication Line. When connecting the communication cable to this slave station, solder the DA (blue), DB (white), DG (yellow), and shield (SLD) lines to relevant terminals of the water-proof connector. Additionally, perform the 3rd grade or higher construction work on the FG terminal.
Page 28
4 INSTALLATION 3) Insertion and removal of water-proof connector (1) Attach Make plug matched with receptacle guide and push it straight. (Since 5-key method is used, make the plug in contact with the receptacle and turn the plug to make the plug matched with the guide.) (2) Removal Turn the coupling nut 45°in the direction...
Page 29
4 INSTALLATION (4) Pre-solder the core wires of the cable with the wire ends processed. Do not pre-solder core wires until the sheath part of the cable. Carefully perform the pre-soldering so that the finish status is smaller than the diameter of the contact hole and the core wires are soldered evenly.
Page 30
4 INSTALLATION For the signal line, be sure to use the cable conforming to the CC-Link specification. ! CAUTION: CAUTION: CAUTION: CAUTION: Always use a proper cable suitable for applicable cable packing diameter of the water-proof connector. For details, see the product catalog made by Mitsubishi Electric Engineering Corp.
Page 31
4 INSTALLATION Power cable (4-pole for DC) Follow the steps below to connect the power cable to this product. ① After checking the safety, turn OFF the power supply to be connected to the slave station. ② Check the following pin assignments and connect the slave station power supply and valve power supply to the power cable.
MAINTENANCE 5. MAINTENANCE 5.1 Disassembling and reassembling this product (slave station) Slave station(NM4G※2-T8G※) Loosen the fixing screws on DIN rail of retainer. Remove the hexagon socket bolts (2 bolts). Separate the serial transmission blocks and pull out the tie rod. Pass the serial transmission block through the tie rod and push it between the adjacent blocks without leaving any clearance and then connect.
Page 33
MAINTENANCE 5.2 Troubleshooting Troubleshooting should address the entire system rather than a particular slave station. This slave station unit has its LED indicators similar to those provided on a Mitsubishi remote I/O station. Looking at these indicators and the indicators on the master station unit, you can determine the cause and take corrective action.
Page 34
MAINTENANCE From previous page From previous page From previous page Is the “ PW1” LED lit? Correct the station number setting. Is the power supply voltage in the allowable range? Turn the power OFF and then The unit is faulty. Correct the power supply voltage.
Page 35
MAINTENANCE From previous From previous From previous From previous From previous From previous page page page page page page Correct the transfer rate setting. Turn the power OFF and then Is the data cable properly connected? Fix the data cable connection. The unit is faulty.
MAINTENANCE 6. HOW TO ORDER • Manifold T8G1 (a) No. of port (b) Piping direction (c) Series model (d) Operator type Code Description Code Description Code Description Code Description 3 port valve Top porting(Direct piping) MW4G2 2-position single 5 port valve Side porting(Base piping) 2-position double Back porting(Base piping)