ZLAN ZLAN5143 Series User Manual

ZLAN ZLAN5143 Series User Manual

Device server

Advertisement

Quick Links

ZLAN5143 Serial
Device Server
User Manual
RS232/485/422 to TCP/IP Converter
Modbus TCP to Modbus RTU
CopyRight©2008 Shanghai ZLAN Information Technology Co., Ltd. All right
reserved
Document DI: ZL DUI 20131017.1.0
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZLAN5143 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ZLAN ZLAN5143 Series

  • Page 1 ZLAN5143 Serial Device Server User Manual RS232/485/422 to TCP/IP Converter Modbus TCP to Modbus RTU CopyRight©2008 Shanghai ZLAN Information Technology Co., Ltd. All right reserved Document DI: ZL DUI 20131017.1.0...
  • Page 2 No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or through information storage and retrieval systems, for any purpose other than for the purchaser’s personal use, without the express written permission of Shanghai ZLAN information Technology Co., Ltd.
  • Page 3: Table Of Contents

    Contents Summary ..........................4 Features ..........................6 Technical Parameters ......................8 Instructions ..........................8 Hardware ........................8 485 Character ......................11 Module Configuration ................... 11 Simple TCP Connection Test................13 Simple Virtual Serial Port Test ................15 After-service ........................17...
  • Page 4: Summary

    ZLAN5143 has the function of Modbus TCP converting to Modbus RTU, and the detailed usage please refer to <Modbus Gateway User Manual>. ZLAN5143 is a high performance serial device server developed by Shanghai ZLAN on the basis of ZLAN1003. It has the character of functional and cost-effective. Has the below character: 1) Three-in-one serial port: RS232/RS485/RS422 three-in-one.
  • Page 5 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 1 ZLAN5143 Can be applied to:  Building /Entrance /Door /Security Control System  Power /Electronic /Intelligent Instrument  Bank /Medical Automation System  Stock Exchange System  Industrial Automation System ...
  • Page 6: Features

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 2 Connection Diagram 2. Features 1) Support full duplex, high speed converting, and no packet lost. ZLAN5143 is the first type of full duplex, continuous, and low cost serial server in industry.
  • Page 7 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Mark, Space. Support CTS/RTS hardware flow control. 5) Embedded 485/422 lightning protection function, suitable for outdoor 485/422 communication. 6) Equipped freely with our Windows Virtual Serial & Device Management Tool ZLVirCom. It supports virtual serial and can one-key searching ZLAN5143 or modifying parameters.
  • Page 8: Technical Parameters

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com 3. Technical Parameters Figure Interface: 485/422: Terminal; 232: DB9 Power Supply: 5.5mm, Inside positive outside negative, standard outlet Size: L x W x H =9.4cm×6.5cm×2.5cm Communicate Interface Ethernet: 10M/100M, 2KV surge protection Serial RS232/485/422×1: RXD, TXD, GND, CTS, RTS...
  • Page 9 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com use black anti-radiation SECC board, it’s equipped with two “ears” for easy installation. Figure 3 Figure 4...
  • Page 10 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 5 Item Name Instruction DEF Switch When DEF is push to 1, serial server will start with default parameter (default IP is 192.168.0.254) MODE Switch Keep for following extensions RS232 port...
  • Page 11: 485 Character

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com RS485 port RS485 Terminal DC Plug Power interface; OD 5.5mm, ID 2.1mm Power interface; 5.08mm terminal DC Terminal The RS232 line sequence shows as the following table: Item Name Instruction receiving pin of the serial device server...
  • Page 12 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com manage" and you'll see a list of devices. Figure 3 ZLVircom Main Interface Figure 4 Device List You can see all the current online devices from the device list. Click "Edit Device"...
  • Page 13: Simple Tcp Connection Test

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Products>. 4.4 Simple TCP Connection Test Now we need to test the transparent communication function of the networking products. The transparent communication is what data the computer sends to a networking product, the serial port of the networking product outputs what data.
  • Page 14 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 6 SocketTest Send-receive Interface Figure 7 ComDebug Send-receive Interface From FIG. 6 and FIG. 7, transparent communication between serial port and network port is carried out. If the serial port is connected to a user's serial port...
  • Page 15: Simple Virtual Serial Port Test

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com connection for data collection and control. 4.5 Simple Virtual Serial Port Test Input the IP of ZLAN5102-3 in the web browser and open the login web. Input the password of 123456 and login. Then you open a configuration web and you can change IP, baud rate and so on.
  • Page 16 Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 9 Add Virtual Serial Port Then enter the “device manage”, and double-click the device that you need to bind to the COM5. As shown in FIG. 4, select COM5 from the "virtual serial port" list in the upper left corner.
  • Page 17: After-Service

    Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com Figure 11 Communication via Virtual Serial Port 5. After-service Shanghai ZLAN Information Technology Co., Ltd. Address: 12 floor, D building, No. 80 CaoBao road, Xuhui District, Shanghai, China Phone: 021-64325189 Fax: 021-64325200 Web: http://www.zlmcu.com...