Page 2
Email: sales@grainpro.com GrainPro® Philippines, Inc. Lot 46 Efficiency Avenue, Subic Bay Gateway Park I, Subic Bay Freeport Zone 2222 Philippines Phone: +63 47 252 7884 Fax: +63 47 252 7885 Website: www.grainpro.com Email: salesasia@grainpro.com GrainPro® Kenya Shop A2, Space Apartments Mai Mahiu Road, Near T Mall Nairobi, KENYA Phone: +254 710 933 717 Website: www.grainpro.com...
Page 3
1.1.1. Check the moisture content of the commodity using GrainPro Moisture Meter (MM5) (available for sale from GrainPro, Inc.) to ensure the MC is at a safe level for storage/transport. Recommended Moisture Content: Coffee – 11.5-12% Cocoa – 6-7% Rice – 13-14% 1.1.2.
A worker can also enter the TSL to help spread the TSL material and help correct any folds in the TSL. 4/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
Page 5
Two-thousand four-hundred (2400) grams or 12 bags of GrainPro Dry Bags per 40-footer. Note: 1 GrainPro Dry Bag contains 200 grams of calcium chloride and can absorb grams of moisture 3.1.2. Place the GrainPro Dry Bags in perforated bags or sacks to prevent direct contact with commodity.
Page 6
3.3. SEALING OF 2-TRACK PE ZIPPER 3.3.1. Remove the ventilator from the container door. Then remove the tapes and unfold the excess liner from the door perimeter and let it loose. 6/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
Page 7
3.3.7. Fold extra liner and tape it against the stack. Ensure that no liner is stuck in-between doors. 7/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
Page 8
(½) of the final vacuum (created by the vacuum pump) within five (5) minutes. 3.4.6. If the PDT test failed, check for holes/tears and poorly sealed zippers then repeat the PDT procedures. 8/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
Page 9
CO analyzer or O analyzer. 3.5.1. The flexible adapter hose is included in the GrainPro Carbon Dioxide Analyzer or the user can find equivalent flexible hose from local hardware using the specifications as shown: Inside Diameter 4 mm (0.16 in.) Length >5 cm (2 in.)
4.1.5. Close the cylinder valve after each use; keep closed even when empty. 4.1.6. Never apply flame or localized heat directly to any part of the cylinder. High temperatures may damage the cylinder and could cause the pressure relief device to fail. 10/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
Page 12
2-meter and have matching coupler at cylinder. 4.3.5. Open a section of the zipper and insert the pressure kit. This serves as outlet to discharge O when flushing. 12/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
Page 13
12-24 hours depending on temperature. This is the time to determine the initial concentration of CO 4.3.9. After the required weight of CO has been flushed, immediately: 4.3.9.1. Close the CO cylinder valve. 13/14 GrainPro® TranSafeliner™ Instruction Manual (Vacuum Method) MA4081RAD1219-01...
6. RECYCLING 6.1. RECYCLING GrainPro TSL is made of polyethylene with barrier layer. 6.1.1. The products can be delivered to the nearest recycling facilities in the area. 6.1.2. Plastic #4 – LDPE (Low Density Polyethylene) can be recycled into compost bins, paneling, trash can liners and cans, floor tiles, and shipping envelopes.