Do you have a question about the 761210 and is the answer not in the manual?
Questions and answers
Summary of Contents for Global 761210
Page 1
USER MANUAL MODEL# 761210:Retrofit Toilet/Urinal Flush Sensor Kit for Royal and Regal Sloan MODEL# 761211:Retrofit Toilet/Urinal Flush Sensor Kit for Zurn...
PRODUCT STRUCTURE Infrared Sensor: Chrome-Plated Metal Casting Cover Accurate,stable performance, even in the sunlight or any light. Adjustable sensor range: 15~32 inch. Operates on 4 AA Alkaline Batteries Adjustable Flush Volume Closet:1.28/1.6/2.4 GPF Latching Solenoid Operator Urinal:0.25/0.5/1.0/1.5 GPF Interchangeable from Closet Manual Mechanical Override to Urinal Valve Button:...
SPECIFICATION Product Retrofit Kit for Water Closet Flush Valve Casing Material Chrome Plated Power Supply 4 AA Alkaline Batteries Power Consumption Battery Life 3 Years (Based on 3,000 cycles per month) Sensing Distance Adjustable 1-9/16"~3-5/32" (40 - 80cm) Minimum Detection Time 5 Seconds Flush Delay Time 3 Seconds...
Page 4
HOW TO USE A. Closet Flush Valve 1. A continuous invisible light beam is emitted from the sensor. As the user enters the beam's effective range (1-9/16"~3-5/32" ) more than 5 seconds, the output circuit continues in a "hold" mode for as long as the user remains within the effective range of the sensor.
Page 5
INSTALLATION AND CAUTIONS 1. Select the model (761210 / 761211) 761210:Retrofits for Royal, Regal (Sloan) Manual Flush Valve 761211:Retrofits for Zurn Manual Flush Valve Control Stop Cap 2. Remove Control Stop Cap and turn off water supply at Stop Cap.
Page 6
4. Remove Handle Assembly and Gasket. Handle Assembly & Gasket 5. Install New Handle Cap with Gasket to handle opening on Flushometer Body. Tighten Handle Cap securely Tighten Handle Cap securely. Handle Cap with Gasket 6. Remove the plastic blue cover under the retrofit kits.
Page 7
7. Place entire Retrofit Assembly onto the valve body. Use provided plastic tool or Strap Wrench tightly secure Locking Ring. Screw Plastic Sleeve Cover 8. Loosen the two screws with Hexagonal wrench to remove the Plastic Sleeve and then remove the Cover.
Page 8
10. Set up desired flush valve function as illustrated. Closet Urinal ON:Closet OFF:Urinal 11. Using a flat head screwdriver, turn on the water supply for operation testing. 12. Adjust volume as needed Vol Adjustment Dual Flush ( Water Closet Only) Light Flush (1.1 GPF):...
Page 9
13. Sensing Range adjustment. Sensing Range Adjustable 1-9/16"~3-5/32" Adjustment (Adjust only if necessary) 14. Reinstall the Cover and Plastic Sleeve as illustrated. 15. Installation is Complete.
TROUBLESHOOTING Trouble Possible cause Troubleshooting Replace batteries Red light flashing 1. Low battery (4) AA Alkaline Replace batteries 1. Low battery (4) AA Alkaline Wipe sensor window with tissue Not flushing 2. Dirty sensor window paper (Red light does not appear during 3.